> Errors diagnostics:
In diagnostics state:
- TEMPER TURE LEDS shall encode the error.
- ECO led shall be off.
- RE DY (with ECO version) leds shall be off.
- WIFI led (with WIFI version) state is given by Wifi state
If more than one occurs, the one to be shown depends on priority (1 is highest). So, for
example, if Error Relay Stuck occours and in a second time an NTC short is checked, only
the Relay error with a highest priority is shown. Errors codification is given by tables
below.
If a new error occurs while the HMI is in diagnostics state, the HMI shall not leave this
state and the diagnostics shall not be updated.
fter 25 seconds the system will come back in lockout state, but if error is removed
before timeout elapses the diagnostic state is not left.
Errors codification is given by tables below. The led on the left is the 40°C led, while the
one on the right is 80°C led.
N
otV
olat
ile
Err
ors
Vola
til
eE
rro
rs
Vo
la
tile
W
arn
in
gs
ERROR_RELAY_STUCK
ERROR_DRY_HEATING
ERROR_NTC_LOW_OVERHEATING 0x0004
ERROR_NTC_HIGH_OVERHEATING 0x0008
ERROR_BAD_DATA_FLASH
ERROR_CANT_UNLOCK
ERROR_NTC1_SHORTED
ERROR_NTC1_OPEN
ERROR_NTC2_SHORTED
ERROR_NTC2_OPEN
ERROR_NFC_DATA
WARNING_TOUCH_COMM
WARNING_WIFI_COMM
WARNING_NFC_COMM
BITMAP
0x0002
0x0001
0x0020
0x0010
0x0001
0x0002
0x0004
0x000
8
0x4000
0x0002
0x0008
0x0010
LEDS MASK
00111
00011
00001
00001
10000
00100
00100
00100
00100
01110
00010
00110
00101
(not displayed
Leds
with TEMP leds)
3
PRIORITY
1
2
2
4
6
6
6
6
7
-
11
7
Table 1: Errors Diagnostics