PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
27
<x>
for PSS & PSH can only be 1.
Returns:
<NR 2>
Examples :
:CHANnel1:MEASure:VOLTage?
might return 11.55 to indicate the
voltage at the channel 1 output is 11.55 V.
:CHANnel<x>:PROTection:CURRent
Function:
Set or query the overcurrent protection status of the specific channel.
Syntax:
:CHANnel<x>:PROTection:CURRent <Boolean>
:CHANnel<x>:PROTection:CURRent?
<x>
can be 1 or 2 or 3,
<Boolean>
can be 0 (OFF) or 1(ON).
<x>
for PSS & PSH can only be 1.
Returns:
0|1
Examples :
:CHANne1:PROTection:CURRent
0 sets the over -current protection
off.
If the overcurrent protection setting is on, the command
of
:CHANne1:PROTection:CURRent?
will return the value of 1.
:CHANnel<x>:PROTection:VOLTage
Function:
Set or query the over voltage protection value of the specific channel.
PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
28
Syntax:
:CHANnel<x>:PROTection:VOLTage < NR2>
:CHANnel<x>:PROTection:VOLTage?
<x>
can be 1 or 2 or 3,
<NR2>
Please refer to the specification.
<x>
for PSS & PSH can only be 1.
Returns:
<NR2>
Examples :
:CHANnel1:PROTection: VOLTage 12.0
sets the channel 1
overvoltage protection limit to 12.0 volts.
:CHANnel1:PROTection: VOLTage?
returns 2.34 if the channel 1
overvoltage protection limit setting is 2.34 volts.
:OUTPut:COUPle:TRACking
Function:
Change the output of the channel 1 and channel 2 to series -tracking or
parallel-track ing or independent output mode (The PSS and PSH series
do not have this function).
Syntax:
:OUTPut:COUPle:TRACking <NR1>
:OUTPut:COUPle:TRACking?
<NR1>
can be 0 (INDEPENDENT) or 1 (PARALLEL -TRACKING) or
2 (SER IES -TRACKING ).
Returns:
0|1|2
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com