IWM-LR3 - IWM-LR4
User Manual v1.0
19
3.11 GET_ALARM_DATA (0x28)
A command used to read alarm detection parameters.
R2H:
H2R:
The AlarmData field is as follows:
The Err field in the answer can take on the following meanings:
0x00 - No Error
0x02 - Device TypeError. The device type is incorrect.
0x03 - Incorrect request, password was not presented
0x04 - Length Error
HEADER property
Date
Fct
C/R/A
Err
Chain
Len
Device Type
property
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
0x28
0
0
0
0x01
0x04
HEADER property
Date
Fct
C/R/A
Err
Chain
Len
Device Type AlarmData,
In
1 byte
1 byte
1 byte
1 byte
1 byte
1 byte
28 bytes
0x28
0
0
0
0x1D property
0x04
Name
Type
Default
Minimal
Maximum
Description
Index
Finger Date
Alarm Flags
Uint32_t
0x0000000000 0x0000000000 0x3F property
Bit 0: magnetic
Bit 1: Removal
Bit 2: Blinding
Bit 3: Loss bit
Bit 4: Reverse stream
Bit 5: Low battery
1 – 4
Magnetic
Alarm Date
Uint32_t
0x0000000000 0x0000000000 0xffffffff
dd/mm/yy
5 – 8
Form Removal
Alarm Date
Uint32_t
0x0000000000 0x0000000000 0xffffffff
dd/mm/yy
9 – 12
Blinding Alarm
Date
Uint32_t
0x0000000000 0x0000000000 0xffffffff
dd/mm/yy
13 – 16
Date
Detection/Loss
Resolution
Uint32_t
0x0000000000 0x0000000000 0xffffffff
dd/mm/yy
17 – 20
Reverse Flow
Alarm Date
Uint32_t
0x0000000000 0x0000000000 0xffffffff
dd/mm/yy
21 – 24
Low battery
alarm date
Uint32_t
0x0000000000 0x0000000000 0xffffffff
dd/mm/yy
25 – 28