DR (DI3 Configuration)
Command
<Serial Interfacing> DR
Command is used to configure
DI3 (pin 2, SLEEP) for I/O line
passing (use with CD = 1 or 2
and CO) or controlling
connection status (use with MD
= 1 or 2).
DT (Destination Address)
Command
<Networking & Security> DT
Command is used to set the
networking address of an Zlinx
Module. Zlinx Modules use three
filtration layers: Channels
(ATHP), Vendor Identification
Number (ATID) and Destination
Addresses (ATDT). DT
Command assigns an address to a module that enables it to communicate only with
other modules having the same addresses. All modules that share the same
Destination Address can communicate freely with each other. Modules in the same
network with a different Destination Address (than that of the transmitter) will listen to
all transmissions to stay synchronized, but will not send any of the data out their serial
ports.
E0 (Echo Off) Command
<Command Mode Options> The
E0 command turns off character
echo in AT Command Mode.
By default, echo is off.
AT Command: ATDR
Binary Command: 0x2D (45 decimal)
Parameter
Range:
0
– 4
Parameter
Configuration
0
Disabled
1
DI3 I/O passing enabled
2
Connect on low
3
Disconnect on high
4
Connect and Disconnect
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: CD (DO3 Configuration),CO
(DO3 Timeout), MD (RF Mode)
Minimum Firmware Version Required: 4.30
AT Command: ATDT
Binary Command: 0x00
Parameter Range:
0
– 0xFFFF
Default Parameter Value: 0
Number of bytes returned: 2
Related Commands: HP (Hopping Channel), ID
(Module VID), MK (Address Mask)
AT Command: ATE0
Binary Command: 0x0A (10 decimal)