Software User Manual - Argos3D - P33x
Last change: 29 June 2020/Version 10
5.7
Sequencing
Addr
(hex)
Register
Name
Default Value
(hex)
R/W Description
0120
NofSequ
1
R/W Number of sequences recorded by the ToF sensor
without wait time in between, 1…4
0121
IntTimeSeq1
05DC
R/W Integration time to be used for capturing sequence 1
NOTE: Sequence 0 integration time is set via register
IntegrationTime
0122
IntTimeSeq2
05DC
R/W Integration time to be used for capturing sequence 2
0123
IntTimeSeq3
05DC
R/W Integration time to be used for capturing sequence 3
0128
ModFreqSeq1 07D0
R/W Modulation frequency to be used for capturing sequence
1
Register description: See
ModulationFrequency
0129
ModFreqSeq2 07D0
R/W Modulation frequency to be used for capturing sequence
2
Register description: See
ModulationFrequency
012A
ModFreqSeq3 07D0
R/W Modulation frequency to be used for capturing sequence
3
Register description: See
ModulationFrequency
Table 5-7: Registers for Sequencing
5.8
Illumination Configuration
Addr
(hex)
Register Name
Default
Value
(hex)
R/W Description
0155
IllPreheatingTimeConsecutive 0000
R/W Pre heating time in microseconds for all phases
except the very first after a trigger
Table 5-8: Registers for Illumination Configuration
5.9
Test Commands
Addr
(hex)
Register
Name
Default
Value (hex)
R/W Description
01C0
TestConfig
0000
R/W Bit[1]
: 1… Watchdog Test