SRP-F310/312
Rev. 1.01
BIXOLON
- 84 -
<Function 081> GS ( k pL pH cn fn m (fn=81)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
m
Hex
1D
28
6B
03
00
30
51
m
Decimal
29
40
107
3
0
48
81
m
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=81
m=48
Default:
None
Description:
This command encodes and prints the PDF417 symbol data in the symbol save area.
Remarks:
■
In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is
empty.
■
A symbol exceeding the printing area in size can not be printed.
■
Printing operation is not processed under the following conditions:
•
There is no data (Function 080 is not processed).
•
If [(number of columns x number of rows) < number of code word] when automatic processing is specified for
number of columns and number of rows.
•
Number of code word exceeds 928 in the data area.
■
The following data is added automatically by the encode processing:
•
Start pattern and stop pattern.
•
Indicator code word of left and right.
•
The descriptor of symbol length (the first code word in the data area).
•
The error correction code word calculated by modulus 929.
•
Pad codeword.
■
The data area includes the following codewords:
•
Data specified by Function 080.
•
The descriptor of symbol length (the first code word in the data area).