Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 23 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
info@blinkgroup.com
PowerTruck_CANOpen_UM_REV1.5
c)
Sub 3 - LED green blink state
Note: if the blink message is sent when the LED is already on, the LED blinks in alternate mode.
Identifier
615h (600h + current CAN ID)
Byte 0
27h
Set Device Register
Byte 1
01h
CAN Object 2001h
Byte 2
20h
Byte 3
03h
Sub index
Byte 4
LG8 LG7 LG6 LG5 - LG4 LG3 LG2 LG1
LED green blink
Byte 5
LG16 LG15 LG14 LG13 – LG12 LG11 LG10 LG9
LED green blink
Byte 6
0 0 0 0 – 0 0 LG18 LG17
LED green blink
Byte 7
00h
Not used
Examples:
Direction
Identifier Format
Data
LED
To Keypad
615
Std
27 01 20 03 00 00 00 00 No LED green blink
To Keypad
615
Std
27 01 20 03 20 00 00 00 Green LED #6 blinks
To Keypad
615
Std
27 01 20 03 00 44 00 00 Green LED #11 and 15 blink
To Keypad
615
Std
27 01 20 03 00 00 03 00 Green LED #17 and 18 blink
Keypad reply
595
Std
60 01 20 03 00 00 00 00
d)
Sub 4 - LED red blink state
Note: if the blink message is sent when the LED is already on, the LED blinks in alternate mode.
Identifier
615h (600h + current CAN ID)
Byte 0
27h
Set Device Register
Byte 1
01h
CAN Object 2001h
Byte 2
20h
Byte 3
04h
Sub index
Byte 4
LR8 LR7 LR6 LR5 - LR4 LR3 LR2 LR1
LED red
Byte 5
LR16 LR15 LR14 LR13 – LR12 LR11 LR10 LR9
LED red
Byte 6
0 0 0 0 – 0 0 LR18 LR17
LED red
Byte 7
00h
Not used
Example:
Direction
Identifier Format
Data
LED
To Keypad
615
Std
27 01 20 04 00 00 00 00 No LED red blink
To Keypad
615
Std
27 01 20 04 18 00 00 00 Red LED #4 and 5 blink
To Keypad
615
Std
27 01 20 04 00 21 00 00 Red LED #9 and 14 blink
To Keypad
615
Std
27 01 20 04 00 00 01 00 Red LED #17 blinks
Keypad
reply
595
Std
60 01 20 04 00 00 00 00