Communications Manual Rev 3.21
Software Versions 3.xx
003R-618-321
Page
21
5.2.3. Permission
Command: CMD_READ_PERMISSION
Return:
This property returns a string of characters, indicating the
permission bits for the register. The characters are (in order):
•
Read
Permission
•
Write
Permission
•
Calibration
Counter
•
Configuration
Counter
Read
Write
Calibration
Counter
Configuration
Counter
“-“ None (any)
“-“ None (any)
“-“ None
“-“ None
“S” Safe
“S” Safe
“C” Affects
“F” Affects
“F” Full
“F” Full
“f” Factory (Internal)
“f” Factory (Internal)
eg. The Permission property of REG_DECIMAL_PLACES returns “-F-F” which
means:
•
Read with any permission (always available).
•
Write with Full permission.
•
Does not affect Calibration Counter.
•
Affects
Configuration
Counter.
5.3. Type Specific Properties
The behaviour of the following properties depends on the type of register.
5.3.1. RangeMin, RangeMax
All Registers have a concept of RangeMin and RangeMax. The register must
contain a value that is in the range RangeMin <= Value <= RangeMax.
Command: CMD_READ_RANGE_MIN
Return: Hexadecimal
Register Type
RangeMin
RangeMax
TYPE_SHORT,
TYPE_USHORT,
TYPE_LONG,
TYPE_ULONG
Minimum value
Maximum value
TYPE_STRING,
TYPE_BLOB
0
(No. of elements -1)
TYPE_OPTION,
TYPE_MENU
0 (No.
of
Elements-1)
TYPE_BITFIELD
0
(No. of character positions – 1)
Summary of Contents for X320
Page 1: ...IP69K Washdown Indicator Communications Manual 800 223 4227 www cas usa com U51024290 ...
Page 47: ...Communications Manual Rev 3 21 Software Versions 3 xx Page 46 003R 618 321 Notes ...
Page 48: ...Communications Manual Rev 3 21 Software Versions 3 xx 003R 618 321 Page 47 Notes ...
Page 49: ...Communications Manual Rev 3 21 Software Versions 3 xx Page 48 003R 618 321 Notes ...
Page 50: ...Notes ...