MTD2000 AT Command Guide R12
Confidential
DAVISCOMMS (S) PTE LTD
43 /105
AT$SR=<Prefix>,<Recipient>
Note: Send one report.
OK
<Standard Report>
AT$SR
Note: Stop sending report.
OK
Parameters
Prefix
ASCII text of up to 10 alphanumeric characters, limited to the
following characters list:
0-9 a-z A-Z ! # $ % & ‘ ( ) * + - . / : < = > ? @
Recipient
Send report to single or multiple recipients as follows:
D –
Log data into memory
U –
Serial port (UART)
N –
Network channel (TCP / UDP)
Sx or Mx – Single SMS number in decimal (1 to 10)
Mulitple SMS numbers in hexadecimal (001 to 3FF)
Bit presentation for multiple SMS numbers:
Bit #
9
8
7
6
5
4
3
2
1
0
SMS #
10
9
8
7
6
5
4
3
2
1
Interval
Interval between reports in second:
Internal Memory – 60 to 65000 sec
SMS Channel – 5 to 65000 sec
Other Channel – 1 to 65000 sec
Cycle
Number of reports to be sent (1 to 65000 reports, 0 is non-stop
sending)
Example
Command
Response
AT$SR=”Location”,”D”
Note: Log one report into memory.
OK
AT$SR=”Location”,”U”
Note: Send one report via serial port.
OK
<Standard Report>
AT$SR=”Location”,”N S1”
Note: Send one report via network channel and
SMS number 1.
OK
<Standard Report>