Multi Service Edge Device HL950
Administrator’s Guide
Page 41 (159)
EN/LZT 108 5995 R3
June
2003
4.2.5
CES over IP
The CES IP commands controls the Circuit Emulation Service over IP networks.
Figure 16
CES over IP
Use the ADD command prefix to add a new CES IP individual for new connections. The SET
command prefix is used for setting the record’s parameter values. The NAME value is used for
mapping CES IP individuals to DATA WAN AAL5 interface individuals. The SAVE command is
used to commit new parameter values to non-volatile memory.
For detailed information about prefixes and parameters for the CES IP command, see chapter 6.2.2.
4.2.6
Typical CES over IP Examples
The following examples show how to configure CES for IP (the default parameter values are
underlined):
1. Set the interface:
HL950>
set interface line x1:ftype=<e1|t1>,
lcode=<hdb3|ami|b8zs>, tmode=<unframed|framed>, crc=<on|off>,
cas=<on|off>, cmode=<master|slave>,
loop=<remote|local|both|off>;
HL950>
save
(to store the configuration)
2. Show the line interface:
HL950>
show interface line x1
3. Add a CESoIP session:
HL950>
add ces ip:name=<name>, ip=<ipaddr>, port=<port number
for axerra|cbid for rad|2142>, payload=<ms for axerra|cells/ip
pkt for rad|1ms/5cells>, cesoip=<axerra|rad>, speed=<e1|t1|n
(where n=3-32)>, clock=<adaptive|network|external|internal>,
jb=<10>;
HL950>
save
(to store the CESoIP session)