Programming Guide
Notes:
(1) Commands may appear as Polled for (queried), Burst string item or Set command
(2) n = number, X = uppercase letter.
(3) see section 10.3.2 Burst Mode, page 50
(4) Setting either Average, Peak Hold or Valley Hold, sets non concerned signal post processing settings to factory default value
(5) In current scale °C or °F
(6) The sensor restarts after a baud rate change. (Command is not allowed in multidrop mode.)
(7) No effect if relay in alarm mode.
(8) Non-zero setpoint value puts unit in setpoint mode. Setpoint is in current scale °C or °F and must be within unit’s temperature range.
(9) Error Codes returned out of ?EC-Command (16 Bit-Word, 0000000000000000 – 1111111111111111)
2
15
2
14
2
13
2
12
2
11
2
10
2
9
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
A
la
rm
d
ete
ctio
n
N
ar
ro
w
b
an
d t
em
pe
ra
tu
re
o
ve
r r
an
ge
N
ar
ro
w
b
an
d t
em
pe
ra
tu
re
u
nd
er
ra
ng
e
W
id
e
ba
nd
te
m
pe
ra
tu
re
o
ve
r r
an
ge
W
ide
ba
nd t
em
pe
ra
tur
e u
nd
er
ra
ng
e
Two
-c
ol
or
te
m
pe
ra
tu
re
o
ve
r r
an
ge
Two
-c
ol
or
te
m
pe
ra
tu
re
u
nd
er
ra
ng
e
A
tte
nu
atio
n >
9
5%
("
dir
ty
w
in
do
w
")*
* (1
)
A
tte
nu
atio
n to
o h
ig
h (
>
95
%
) (
1)
En
er
gy t
oo l
ow
N
ar
ro
w
b
an
d d
ete
cto
r f
ailu
re
W
ide
ba
nd d
et
ec
to
r f
ai
lur
e
In
te
rn
al
te
m
pe
ra
tu
re
u
nd
er
ra
ng
e
In
te
rn
al te
m
pe
ra
tu
re
o
ve
r ra
ng
e
H
ea
te
r c
on
tr
ol
te
m
pe
ra
tu
re
u
nd
er
ra
ng
e
H
ea
te
r c
on
tr
ol
te
m
pe
ra
tu
re
o
ve
r r
an
ge
Table 4 Command List
10.5
Command Examples
HOST
SENSOR
HOST
WHERE USED (1)
Description
Query
Answer
Set
P
B
S
Burst string format
001?$
001!$UTSI
001$=UTSI
√
√
Show list of commands
001?
√
Measured attenuation
001?B
001!B12
√
√
Baud rate
001?D
001!D384
001D=384
√
Emissivity
001?E
001!E0.95
001E=0.95
√
√
√
Average time
001?G
001!G1.2
001G=1.2
√
√
√
Top of mA range
001?H
001!H2000.0
001H=2000.0
√
√
√
Sensor internal ambient
001?I
001!I37.9
√
√
Switch panel lock
001?J
001!IJL
001J=L
√
√
Relay alarm output control
001?K
001!K0
001K=0
√
√
Bottom of mA range
001?L
001!L1200.0
001L=1200.0
√
√
√
Mode – ER series
001?M
001!M1
001M=1
√
√
√
Target temperature, 1-color narrow
001?N
001!N1158.0
√
Output current
001?O
001!O10
001O=10
√
√
√
Peak hold time
001?P
001!P5.6
001P=5.6
√
√
√
Power
001?Q
001!Q36.102000
√
√
Narrow Power
001?R
001!R2.890000
√
√
Slope
001?S
001!S0.850
001S=0.850
√
√
√
Target temperature,
ER series 2-color
001?T
001!T1225.0
√
√
Temperature units
001?U
001!UC
001U=C
√
√
√
Poll/Burst mode
001!VP
001V=P
√
ENDURANCE 1R
Rev. E1 Sep 2015
53
1.800.868.7495
info@Raytek-Direct.ca