23
RS-232 SERIAL CONTROL
Functions Syntax
The syntax for each function is always the same:
#Function name
→
Space ( _ ) as function name end
fl
ag
→
Parameter 1
→
Space
→
Parameter 2
→
Parameter n
→
Carriage Return ( \r )
→
Sample:
#FunctionName_param1_param2_param3_param4...\r
Syntax is NOT case sensitive.
Functions
Function
Description
#ASPECT
Sets the aspect ratio of the output signal
#AUTOLOCK
Enables or disables the automatic genlock mode
#BLACKLEV
Sets the black level (RGB/Y) of the output signal
#BRIGHT
Sets the brightness value for a speci
fi
c color
#CLEANAPER
Sets the clean aperture level for position and size
#COLRANGE
Sets the color range (limited or full) of the output signal
#CONTRAST
Sets the contrast level for a speci
fi
c color
#CUSTOM
Used to modify the output format
#DEVERSION
Returns the hardware and
fi
rmware version
#ENHANCE
Sets the enhancement value
#EXTRACT
Sets the extract aspect mode
#GAMMA
Sets the Gamma correction mode
#INPUT
Sets the input format of the image
#INSEL
Sets the input channel
#LANGUAGE
Sets the current language of the OSD
#LINKCONF
Changes the link con
fi
guration
#LIST
Displays a list of all available functions on this Scaler
#MOTIONTHRES
Sets the intraframe motion detection threshold
#NOISEREDUC
Sets the noise reduction value
#NOISETHRES
Sets the noise reduction threshold
#OUTCONF
Sets the output link con
fi
guration
#OUTPUT
Sets the format (refresh rate) of the output signal