38
RS-232 SERIAL CONTROL
#SAVE Function
The #SAVE function saves all the current parameters in the PROM. These
parameters will be reloaded upon the next boot up.
Syntax:
#SAVE
Parameters:
None
#SIZEPOS Function
The #SIZEPOS function sets the size and the position of the image. Note that
this option is not available in the panoramic aspect mode.
Syntax:
#SIZEPOS param1 param2 param3 param4
Parameters:
param1
Horizontal size
Minimum value
Maximum value
1
Current horizontal resolution
- current horizontal position
param2
Vertical size
Minimum value
Maximum value
1
Current vertical resolution -
current vertical position
param3
Horizontal position
Minimum value
Maximum value
0
Current horizontal resolution
- current horizontal size
param4
Vertical position
Minimum value
Maximum value
0
Current vertical resolution
- current vertical size