www.haiwell.com
Haiwell PLC - Temperature & Humidity Module User Manual
Contents
Temperature & Humidity Module Use Manual
1. Product model list and dimension
..................................................................................................................................................................
3
2. Indicator description
.........................................................................................................................................................................................
4
3. Power supply specification
..............................................................................................................................................................................
4
4. Environmental specifications for product
......................................................................................................................................................
4
5. Main parameters for modules
.........................................................................................................................................................................
5
5.1 Main parameters for digital temperature and humidity modules
...................................................................................................
5
5.2 Main parameters for thermal resistance and thermocouple modules
..........................................................................................
5
6. Wiring diagram
..................................................................................................................................................................................................
5
6.1 Digital temperature and humidity module: Single / multiple DS18B20, RW1820, DS1990 sensor input wiring diagram
....
5
6.2 Thermal resistance and thermocouple module wiring diagram
.....................................................................................................
6
7. Terminal wiring diagram
...................................................................................................................................................................................
6
8. Module parameter table
(
CR code is corresponding to the Modbus register address
)
....................................................................
6
8.1 Parameter table for digital temperature and humidity modules
.....................................................................................................
6
8.2 Parameter table for 4-channel thermal resistance and thermocouple modules
.........................................................................
7
8.3 Parameter table for 8-channel thermal resistance and thermocouple modules
.........................................................................
8
9. Expansion modules installation
......................................................................................................................................................................
9
Temperature & Humidity modules Application Case
1. Expand module through the host PLC parallel port
..................................................................................................................................
10
1.1 Module power supply
......................................................................................................................................................................
10
1.2 Temperature modules need't be written any conversion program, read the current temperature value directly when
access the sensor
......................................................................................................................................................................................
10
1.3 Programming skills for PLC
............................................................................................................................................................
11
1.5 Default for using engineering, when the engineering value is not used, the default code value is 0 ~ 32000
.................
11
1.6 Module CR code application example: Read module channel disconnection alarm
............................................................
12
2. Module used as remote IO
...........................................................................................................................................................................
12
1.1 Module power supply
......................................................................................................................................................................
12
1.2 Communication port introduction
...................................................................................................................................................
12
1.3 Communication protocols and default parameters
.....................................................................................................................
12
1.4 Introduce module parameter configuration method when the module is used as remote IO
..............................................
13
1.5 Parameter configuration example: Configurate module by programming software remote module tool
...........................
13
1.6 Remote IO appliciation example(RS485 mode): PLC reads 4-channel temperature value of H04RC module
...............
15
1.7 Remote IO appliciation example (Ethernet mode): PLC reads and writes every channel input values of H08RC-e
module
.........................................................................................................................................................................................................
15
1.8 Remote IO appliciation example: Haiwell Cloud configuration communicates directly with H08TC module
....................
16
1.9 H04DT module usage features introduction
................................................................................................................................
17
1.10 H32DT module usage features introduction
..............................................................................................................................
18
FAQ for H32DT module
.....................................................................................................................................................................................
21