Appendix B. The IBM 8237 Management Information Base
B-17
SYNTAX INTEGER (1..10)
ACCESS read-only
STATUS mandatory
DESCRIPTION "ID number of a hub unit, used to select it."
::= { basicFemEntry 1 }
basicFemType OBJECT-TYPE
SYNTAX INTEGER {
not-present(1),
100base-tx(2),
100base-fx(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Port type of the FEM port."
::= { basicFemEntry 2 }
basicFemLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
goodlink(1),
badlink(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "Link status of the FEM port."
::= { basicFemEntry 3 }
basicFemDuplexStatus OBJECT-TYPE
SYNTAX INTEGER {
half-duplex(1),
full-duplex(2),
auto-negotiation(3),
negotiated-half-duplex(4),
negotiated-full-duplex(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Setting this object to full-duplex(2) enables
the FEM port for full-duplex mode, so that the
port can send and receive frames at the same
time. Setting this object to auto-
negotiation(3) lets the transceiver decide the
duplex status of the port. The result of the
auto-negotiation is reflected as negotiated-
half-duplex(4) or negotiated-full-duplex(5).
Setting to these two values is not valid;
’snmpBadValue’ will be returned."
::= { basicFemEntry 4 }
basicFemBackPressureStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "Setting this object to enabled(1) enables the FEM
backpressure feature. When the output queue is
full, the FEM port will generate collisions
back to the source network everytime a frame is
received.
Setting this object to disabled(1) lets the FEM
port discard the input frames of the source
network when the output queue is full."
::= { basicFemEntry 5 }
basicFemForwardingMode OBJECT-TYPE
Summary of Contents for 8237
Page 1: ......
Page 2: ......
Page 7: ...vi 8237 Hub Installation and Planning Guide...
Page 15: ...xiv 8237 Hub Installation and Planning Guide...
Page 41: ...2 8 8237 Hub Installation and Planning Guide...
Page 91: ...3 50 8237 Hub Installation and Planning Guide...
Page 109: ...4 18 8237 Hub Installation and Planning Guide Figure 4 20 8237 Field Replaceable Parts...
Page 113: ...4 22 8237 Hub Installation and Planning Guide...
Page 117: ...A 4 8237 Hub Installation and Planning Guide...
Page 147: ...B 30 8237 Hub Installation and Planning Guide...
Page 166: ...Part Number 85H8847 Printed in Taiwan 85H8847 GA27 4186 00...