7. Blinking Settings
Blink the bar graph when the value of the specified device exceeds the upper or lower limit.
For the blinking speed, see "MSG Instruction Common Settings" on page 12-9.
Maximum, minimum, upper limit, and lower limit values must satisfy the following condition.
■
MSG Instruction Common Settings
The common settings, character set, scroll unit, scroll speed, and blinking speed, for the message to display can be configured.
The common settings are configured in the
LCD
tab of the
HMI Module Configuration
dialog box that is displayed from the
WindLDR
Expansion Modules Configuration
.
Note:
The common settings for the MSG instructions are applicable for all MSG (message) instructions in the user program. For the MSG instruction
individual settings, see "MSG Instruction Individual Settings" on page 12-2.
HMI Module Configuration dialog box LCD tab
1. Character Set
The character set used for the messages can be configured from the following.
2. Scroll Unit
The unit to scroll the texts can be configured.
3. Scroll Speed
The speed to scroll the texts can be configured. The setting range is 500 to 1,000 ms.
4. Blink Speed
The speed to blink the texts can be configured. The setting range is 500 to 1,000 ms.
Note:
The MSG instruction character set can be configured irrespective of the HMI module system menu language.
Blinking Settings
Description
Upper limit
The bar graph is blinked when the value of the specified device is larger than the upper limit.
Lower limit
The bar graph is blinked when the value of the specified device is smaller than the lower limit.
Selection
Character Set
Languages Usable in the MSG Instruction
European
ISO-8859-1 (Latin 1)
Italian, English, Dutch, Spanish, German, French
Japanese
Shift-JIS
Japanese
Chinese
GB2312
Chinese (simplified)
Cyrillic
ANSI 1251
Russian
One character
Scrolls the text in 1 character units.
One dot
Scrolls the text in 1 dot units.
Line A monitor
Target count:
Prod. count:
30000
14500
Min
Lower limit
Upper limit
Max
<
<
<
1.
2.
3.
4.
Summary of Contents for MICROSmart FC6A Series
Page 1: ...B 1726 7 FC6A SERIES Ladder Programming Manual ...
Page 8: ...Preface 7 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 32: ...1 OPERATION BASICS 1 20 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 96: ...3 INSTRUCTIONS REFERENCE 3 18 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 130: ...4 BASIC INSTRUCTIONS 4 34 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 192: ...9 SHIFT ROTATE INSTRUCTIONS 9 12 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 272: ...12 DISPLAY INSTRUCTIONS 12 24 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 284: ...14 REFRESH INSTRUCTIONS 14 6 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 502: ...25 DATA LOG INSTRUCTIONS 25 22 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 546: ...26 SCRIPT 26 44 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 598: ...APPENDIX A 14 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...