NEO 2 Interface Developer’s Guide
Copyright © 2019, International Technologies & Systems Corporation. All rights reserved.
172
8.4.9.
Contact Retrieve AID List (60-07)
Use this command to return all AIDs list in the reader. This command may be used to verify
configured AIDs in the reader.
Command Frame
Byte 0-9
Byte 10
Byte 11
Byte 12 Byte 13
Byte 14 …
Byte 14+n-1
Byte 14+n Byte 15+n
Header Tag
& Protocol
Version
Command
Sub-
Command
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC (LSB)
CRC (MSB)
ViVOtech2\0
60h
07h
00h
00h
Response Frame
Byte 0-9
Byte 10
Byte 11
Byte 12
Byte 13
Byte 14 …
Byte 14+n-1
Byte 14+n Byte 15+n
Header Tag
& Protocol
Version
Command Status Code
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC (MSB)
CRC
(LSB)
ViVOtech2\0
60h
See Status
Code Table
See Response
Frame Data
Format
Response Frame Data Format:
<NumberL><NumberH> <AID Block 1> <AID Block 2> … <AID
Block N>.
Where:
•
<NumberL><NumberH> is Number of AID Blocks.
•
<AID Block> format is <LenL> <LenH> <Several bytes AID>
Note:
If AID List does not exist, status code is 0x60.
8.4.10.
Contact Retrieve CA Public Key (60-08)
This command can get assign CA Public key form reader.
Command Frame
Byte 0-9
Byte 10
Byte 11
Byte 12 Byte 13
Byte 14 … Byte
14+n-1
Byte 14+n Byte 15+n
Header Tag
& Protocol
Version
Command
Sub-
Command
Data
Length
(MSB)
Data
Length
(LSB)
Data
CRC (LSB)
CRC (MSB)
ViVOtech2\0
60h
08h
Data Objects
Data Objects
<5 bytes RID> <1 byte Index>.