3. Installation 

 

 
Attach serial cable with DB9 

connector and configure serial 
interface of device connected to  

IQS-RS232 to send keep-alive 
data periodically. 

 

 
Serial interface of monitored device must be configured for following 
parameters: 

 
9600 Baud,  bits 8,  No parity,  stop bits 1,    No flow control 

 

4. Basic control commands 

4.1 Controlling output power by commands 

Commands which control output power socket over serial RS232 interface has 
following syntax: 

 

Command 

Description 

Answer 

AT+TURNON 

Turn output power socket on. Applicable only if 
WATCHDOG=OFF. 

-–- 

AT+TURNOFF 

Turn output power socket off. Applicable only if 
WATCHDOG=OFF. 

-–- 

AT+RESET 

Interrupt ouput power for 10 seconds. Applicable 
anytime. 

-–- 

AT+TURN? 

Request for output power status 

ON 
OFF 

 
4.2 Watchdog feature 
 

Command 

Description 

Answer 

AT+WATCHDOGON  Turn on watchog feature. Power socket monitor 

serial interface for activity and provides power until 
no data are received within 4 minutes. 

-–- 

AT+WATCHDOGOFF  Turn off watchog feature. 

-–- 

AT+ECHOON 

Turn on all ECHO messages. Useful feature with 
some applications. 

-–- 

AT+ECHOOFF 

Turn off all ECHO messages. Useful feature with 
some applications. 

-–- 

 

If watchdog feature is activated and no data are coming within 4 minutes (it’s 
expected that monitored device stopped to work from some reasons), IQsocket 

interrupts power on output power socket for 10 seconds. Sending keepalive 
data must be performed by any way (form linus by echo command, or by any 

special OS tool). 