15.3.6
Light Sensor (LIS)
Query the interface board for the surrounding light. The reply will contain a 5 byte ASCII ranging from 00000 to
65535.
Example:
Query the Light Sensor for the current value:
ATTN
ADDR
CMD
LEN
IHCHK
0x07
0x00
0x4C
0x49
0x53
0x00
0x10
Reply from interface board (“00100”):
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
0x06
0x00
0x4C
0x49
0x53
0x05
0x0C
0x30
0x30
0x31
0x30
0x30
0x0E
16
Backlight, color … etc settings
The monitor of DuraPANEL7 & 12 are detected as a Display Port monitor.
DuraPANEL7 & 12 support DDC/CI commands for display settings like brightness, contrast, color luminance, color
temperature.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 22