background image

Models 2601B, 2602B and 2604B System SourceMeter

®

 Instrument Specifications 

 

Specifications are subject to change without notice 

10 of 13 

SPEC-2602B Rev. B / February 2014 

SUPPLEMENTAL INFORMATION 

Front-panel interface 

Two-line vacuum fluorescent display (VFD) with keypad and navigation wheel 

Display 

 

Show error messages and user-defined messages 

 

Display source and limit settings 

 

Show current and voltage measurements 

 

View measurements stored in dedicated reading buffers 

Keypad operations 

 

Change host interface settings 

 

Save and restore instrument setups 

 

Load and run factory and user-defined test scripts that prompt for input and send 
results to the display 

 

Store measurements into dedicated reading buffers 

Programming 

Embedded Test Script Processor (TSP

®

) scripting engine is accessible from any host 

interface: 

 

Responds to individual instrument control commands 

 

Responds to high-speed test scripts comprised of remote commands and test script 
language (TSL) statements (for example, branching, looping, and math) 

 

Able to execute high-speed test scripts stored in memory without host intervention 

Minimum user memory 
available 

16 MB (approximately 250,000 lines of TSP code) 

Test Script Builder 

Integrated development environment for building, running, and managing TSP scripts; 
includes an instrument console for interactive communication with any TSP-enabled 
instrument 

Requires: 

 

VISA (NI-VISA included on the Product Information CD-ROM) 

 

Microsoft

®

 .NET Framework (included on the Product Information CD-ROM) 

 

Keithley I/O Layer (included on the Product Information CD-ROM) 

 

Intel

® 

Pentium III 800 MHz or faster personal computer 

 

Microsoft

®

 Windows

®

 2000, XP, Vista

®

, or 7 

TSP

®

 Express (embedded) 

Tool that allows you to quickly and easily perform common I-V tests without programming 
or installing software 

To run TSP Express, you need: 

 

Java™ Platform, Standard Edition 6 or 7 

 

Microsoft

®

 Internet Explorer

®

, Mozilla

®

 Firefox

®

, or another Java-compatible web 

browser 

Software interface 

TSP™ Express (embedded), direct GPIB/VISA, read/write with Microsoft

® 

Visual Basic

®

Visual C/C++

®

, Visual C#

®

,  LabVIEW™, CEC TestPoint™ Data Acquisition Software 

Package, NI LabWindows™/CVI, and so on. 

Summary of Contents for System SourceMeter 2601B

Page 1: ...and measurement accuracies are specified at the Models 2601B 2602B and 2604B terminals under these conditions 1 23 C 5 C 70 percent relative humidity 2 After a two hour warm up period 3 Speed normal...

Page 2: ...pA 0 03 5 nA 60 pA 10 pA 0 025 1 5 nA 100 A 2 nA 0 03 60 nA 3 nA 100 pA 0 02 25 nA 1 mA 20 nA 0 03 300 nA 6 nA 1 nA 0 02 200 nA 10 mA 200 nA 0 03 6 A 200 nA 10 nA 0 02 2 5 A 100 mA 2 A 0 03 30 A 600...

Page 3: ...ibe the typical performance of the Models 2601B 2602B and 2604B PULSE CHARACTERISTICS Pulse region specifications Pulse region specifications Region quadrant diagram Region maximums Maximum pulse widt...

Page 4: ...HARACTERISTICS Noise 10 Hz to 20 MHz 20 mV peak peak 3 mV RMS 6 V range Transient response time 70 s for the output to recover to within 0 1 for a 10 to 90 step change in load Overshoot Voltage 0 1 10...

Page 5: ...nal value after source level command is processed on a fixed range Voltage range Settling time 100 mV 50 s 1 V 50 s 10 V 110 s 40 V 12 150 s Current source output settling time Time required to reach...

Page 6: ...quired to reach within 0 1 of final value after source level command is processed on a fixed range Values below for Vout 1 V Current range Settling time 1 mA 100 s Input impedance 10 G ADDITIONAL CHAR...

Page 7: ...ge Settling time 3 A and 1A 120 s Rload 2 100 mA and 10 mA 100 s 1 mA 3 ms 100 A 3 ms 10 A 230 ms 1 A 230 ms Capacitor leakage performance Using HIGH C scripts 19 200 ms 50 nA Load 5 F in parallel wit...

Page 8: ...01 NPLC Digital I O 3500 3100 3400 3000 3000 2700 2900 2600 4150 3650 3800 3400 0 1 NPLC Internal 580 480 560 470 550 465 550 460 560 470 545 460 0 1 NPLC Digital I O 550 460 550 460 540 450 540 450 5...

Page 9: ...maximum rate is 190 second Maximum source function change rate 1000 per second Command processing time 1 ms Maximum time required for the output to begin to change after receiving the smua source leve...

Page 10: ...ts for example branching looping and math Able to execute high speed test scripts stored in memory without host intervention Minimum user memory available 16 MB approximately 250 000 lines of TSP code...

Page 11: ...ink expansion interface allows TSP enabled instruments to trigger and communicate with each other See the figure below Each Model 2601B and 2602B has two TSP Link connectors to make it easier to conne...

Page 12: ...or higher LAN crossover cable 9 84 ft 3 m maximum between each TSP enabled instrument USB Control Rear USB 2 0 Device USB TMC488 protocol USB File System Front USB 2 0 Host Mass storage class device...

Page 13: ...current flowing out of digital I O bit 960 A Maximum sink current at maximum logic low voltage 0 7 5 0 mA Absolute maximum sink current flowing into digital I O pin 11 mA 5 V power supply pins Limited...