Register Function

Available Factory
values

pre-set

CV1

Loco address

(00..22)

[3]

CV2

Starting voltage

(0..255)

[0]

voltage for speed setting 1 - if loco starts only at a higher 
speed setting, increase value. With "Back-EMF" function
active, the factory pre-set value should not be changed.

CV3

Acceleration (1 = fast, 255 = slow)

(1..255)

[3]

CV4

Braking (1 = fast, 255 = slow)

(1..255)

[3]

Hint:

When programming with the 55015 Universal Remote,

the following CVs are programmed by input of the number of
the desired CV in CV6 and then input of the desired
function value in CV5 (see example below).

CV5

Max. voltage

(1..255)

[255]

Voltage for highest speed step - if a lower top speed is
desired, decrease value. With "Back-EMF" function active,
the factory pre-set value should not be changed.

CV5 

after input of CV6
function value for CV to be programmed

CV6

CV to be programmed

CV29

Configuration [4]
Normal direction:
4 = Analog and digital, factory-programmed speed steps
0 = Digital only, factory-programmed speed steps
20 = Analog and digital, user-programmed speed steps
16 = Digital only, user-programmed speed steps

Reversed direction:
5 = Analog and digital, factory-programmed speed steps
1 = Digital only, factory-programmed speed steps
21 = Analog and digital, user-programmed speed steps
17 = Digital only, user-programmed speed steps
With "Analog and digital:"
- Loco can operate on analog and digital layouts
With "Digital Only:"
- Normal operation on digital layouts.
- Operation on analog layouts not possible.
Command for steam terminal

[13]

0 = control via lighting button
1 = control via button 1 (buttons F2-F8 not used)
9 = control via button 1 (buttons F2-F8 used)
10 = control via button 2
11 = control via button 3
12 = control via button 4
13 = control via button 5
14 = control via button 6
15 = control via button 7
16 = control via button 8
64 = control via lighting button (On only when reversing)
65 = control via button 1 (On only when reversing)
128 = control via lighting button (On only when moving 
forward)
129 = control via button 1 (On only when moving forward)
Command for front light terminal

[128]

(see CV 51)
command for rear light terminal

[64]

(see CV51)

CV54

Hand-off function and "Back-EMF"

(0..3)

[2]

0 = hand-off function off, Back-EMF off
1 = hand-off function on, Back-EMF off
2 = hand-off function off, Back-EMF on
3 = hand-off function on, Back-EMF on
Hand-off function on: When operating with 55015, you can
adjust direction and speed for two seconds after selecting
a moving loco without causing the loco to stop.

CV55

Reset of most programmed CVs
55 = most important CVs are reset to the factory pre-set 
values

CV60

Back-EMF: Max. adjustment factor (0: small, 255: large)

(1..255)

[48]

Specifies the max. increase or decrease of voltage applied 
during each time interval (programmed in CV61)
Attention! The factory pre-set values of CV60 and CV61 are
optimized for LGB motors.

CV61

Back-EMF: Adjustment frequency (0: often, 255: seldom)

(0..255)

[0]

Specifies how often per second the motor voltage is 
adjusted - accordingly, the loco will react to curves and 
grades immediately or with a short delay

CV62

Back-EMF: Max. Adjustment (0: small, 255: max.)

(0..255)

[255]

Limits the total adjustment in motor voltage. If there is a very
large load on the motor, the adjustment will not exceed this 
value - for more realistic operations, so that locos will slow 
a bit on grades.

CV67

Speed steps programmed by user (see CV29):

(0..255)

to

28 speed steps are programmed in CV67 to CV94.

CV94

With LGB MTS, every second value is skipped (14 speed steps).
Factory pre-set speed steps:
7, 9, 11, 13, 16, 20, 24, 28, 32, 36, 42, 48, 54, 60, 68, 76, 
4, 92, 102, 112, 124, 136, 152, 168, 188, 208, 230, 255
Pre-set values for user-programmable speed steps:
8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96, 104, 112, 120,
128, 136, 144, 152, 160, 168, 176, 184, 192, 208, 224, 240,
255

Hint:

The speed steps are factory pre-set and programming

is not necessary. Use the  55045 MTS PC Decoder
Programming Module for programming.

Summary of Contents for 20872

Page 1: ...silver Analog Digital sticker on the loco packaging Earlier production locos with the same product numbers may still be available at LGB representatives and retailers and may have different MTS decode...

Page 2: ...ilung Garantie Saganer Str 1 5 90475 N rnberg ALLEMAGNE Tel 09 11 83 707 0 LGB OF AMERICA Warranty Service Department 6444 Nancy Ridge Drive San Diego CA 92121 TATS UNIS Tel 858 535 93 87 Veuillez bie...

Page 3: ...ie im LGB Katalog BEDIENUNG Vorbereitung Lok an den Schlepptender kuppeln Den Haken hinten an der Lok ber den B gel vorne am Tender heben Stromkabel anschlieflen Abb 1 Achtung Das Kabel kann durch unv...

Page 4: ...pf und Reinigungsfl ssigkeit liegt bei Den Schornstein nur zur H lfte mit der Fl ssigkeit f llen Wenn zu viel Fl ssigkeit verwendet wird kann diese nicht verdampfen Achtung Nur LGB Dampf und Reinigung...

Page 5: ...eraus ziehen Kabel f r Dampfentwickler von der Platine abziehen Besch digten Dampfentwickler Schornsteineinsatz mit einer Spitzzange oder einer Pinzette aus dem Schornstein ziehen Abb 9 Neuen Dampfent...

Page 6: ...nur bei R ckw rtsfahrt 65 Schalten mit Funktionstaste 1 Ein nur bei R ckw rtsfahrt 128 Schalten mit Lichttaste Ein nur bei Vorw rtsfahrt 129 Schalten mit Funktionstaste 1 Ein nur bei Vorw rtsfahrt Sch...

Page 7: ...l on the cable Pull on the plug only A bag with detail parts is included Attach these parts as shown in the separate instructions Operating Modes This model has a four way power control switch mounted...

Page 8: ...and Cleaning Fluid is included with this model For best operation fill the generator halfway with fluid If the generator is overfilled it will not convert the fluid into smoke 15 Attention Only use LG...

Page 9: ...nt generator into the stack Plug the wires for the smoke gen erator onto the pins on the circuit board Reassemble Replacing the traction tire Remove the hex head screw on the wheel with the traction t...

Page 10: ...when reversing 65 control via button 1 On only when reversing 128 control via lighting button On only when moving forward 129 control via button 1 On only when moving forward Command for front light t...

Page 11: ...21348 41673 Wagon couvert du PRR 41805 Wagon citerne de l UP 43790 Fourgon de queue du PRR 45720 Wagon r frig rant du Santa Fe 47915 Wagon couvert en acier de l UP 65011 Alimentation g n rant du Santa...

Page 12: ...st me multitrain Cette fonction permet de conserver constante la vitesse du moteur ainsi que la vites se de la locomotive en conditions normales m me lorsque la charge de la locomotive change comme pa...

Page 13: ...n autoris s Conseil Des instructions suppl mentaires d expert pour beaucoup de produits LGB sont disponibles en ligne www lgb com Lubrification Les roulements des essieux et les articulations des biel...

Page 14: ...nts se fait en entrant le num ro du registre choisi dans CV6 et en entrant la valeur de fonction choisie dans CV5 voir exemple ci dessous CV5 Tension maximale Tension pour r glage de vitesse le plus h...

Page 15: ...minution maximale de la tension appliqu e pendant chaque intervalle de temps programm e dans CV61 Attention Les valeurs de CV60 et CV61 attribu es par l usine sont optimis es pour les moteurs LGB 1 25...

Page 16: ...contact avec votre reven deur ou avec l un des centres d en tretien ci dessous Ernst Paul Lehmann Patentwerk Reparateur Abteilung Saganer Strasse 1 5 D 90475 N rnberg ALLEMAGNE T l phone 0911 83707 0...

Reviews: