SFA-5000 • SFA-10000 DeviceNet
Thus the linear position value will be as follows:
Linear position value
= 1,569 * 0.05 = 78.45 mm = 78,450 µm
23-01-0B Device type
[UINT, ro]
Type of device.
0002h: multiturn absolute rotary encoder.
23-01-0C Code sequence
[BOOL, rw]
attribute sets whether the position value output by
the encoder increases (count up information) when you rewind the wire (00) or
when you pull the wire out (01, default).
00: rewinding the wire the position will increase;
01: pulling the wire out the position will increase.
WARNING
set a new preset value (see the
save the new parameters (execute the “Save parameters” function, see “7.1.4
Saving the parameters“ in the “7.1 Read and set parameters“ section on page
81).
23-01-0E Scaling function control
[BOOL, rw]
If this attribute is disabled (OFF = 00), the device uses the physical resolution
values (see the
23-01-2A Hardware counts per revolution
attributes); if it is enabled (ON = 01), it uses the
custom resol
23-01-10 Resolution per revolution
attributes with the following relation:
Transmitted position =
23-01-10 Resolution per revolution
* real position
23-01-11 Total measuring range
23-01-2A Hardware counts per revolution
Default = 00h
WARNING
When you enable the scaling function (
23-01-0E Scaling function control
01), please enter scaled values next to the
MAN SFA_5000_10000_FD E 1.0.odt
DeviceNet interface
68 of 88