3DM
®
-GX5-35
DCP Manual
4.3
System Commands
The System Command set provides a set of advanced commands that are specific to devices such as
the 3DM-GX5-35 that have multiple intelligent internal sensor blocks. These commands allow special
modes such as talking directly to the native protocols of the embedded sensor blocks. For example,
with the 3DM-GX5-35, you may switch into a mode that talks directly to another LORD Sensing Inertial
Sensor with an internal IMU.
4.3.1
Communication Mode (0x7F, 0x10)
Advanced
Description
Advanced specialized communication modes.
This will change the communications protocol to and from mode to “GNSS Direct” (u-
bloxM8M protocols on the 3DM-GX5-35). This command is always active, even when
switched to the direct modes. This command responds with an ACK/NACK just prior to
switching to the new protocol. For all functions except 0x01 (use new settings), the new
communications mode value is ignored.
Possible function selector values:
0x01 - Apply new settings
0x02 – Read back current settings
0x03 – Save current settings as startup settings
0x04 – Load saved startup settings
0x05 – Reset to factory default settings
Possible Communications Modes:
Value
Mode
Protocol(s)
0x01
Standard
3DM-GX5-35 MIP Packet
(default)
0x02
Sensor Direct
MIP IMU
0x03
GNSS Direct
NMEA, UBX (GNSS Models only)
Notes
IMPORTANT: GNSS message settings are automatically reloaded when switching from
direct modes back into standard mode.
Note: Switching to and from GNSS Direct Mode takes longer than most commands to
complete due to the amount of GNSS setup data that needs to be stored/retrieved.
Field Format
Field Length
Field
Descriptor
Field Data
Command
0x04
0x10
U8 – Function selector
U8 – New Communications Mode
Reply Field 1:
0x04
0xF1
U8 - Echo the command descriptor