12
REACTION
Each trigger can initiate a maximum of 3 reactions out of the following list:
Reaction
Command
Remark
Switch Output 1
O1ON, O1OFF,
O1TGL
Toggle means the output switches each time the
action is executed, regardless the current status
Switch Output 2
O2ON, O2OFF,
O2TGL
Send SMS
SEND:text
Max. 20 characters. An alarm SMS contains the
identification text and the text as defined here. The text
is also stored as TEXTy, where y stands for the action
rule number.
Call
CALL
The unit calls the set alarm numbers. The receiver will
hear a 2-tone signal
and can confirm by pressing ‘1’.
6.3 PROGRAMMING ACTION RULES
Send following SMS commands in following format:
CODE TRIGGER:REACTION1,REACTION2,REACTION3
• Do not forget the space between CODE and the TRIGGER.
• The Mobeye MS100E will play a short melody to indicate a successful configuration.
In case of a wrong command, a long beep will sound.
6.4 TIME-BASED ACTION RULES
It is possible to let the action be daily performed at a certain time. The time is the trigger.
To program a time-based action, include the time in the action rule, in following way.
CODE TIME:hhmm:REACTION
Example:
Switch output 2, call and send SMS text ‘Pump failure’ after a triggered input2:
1111 IN2:O2ON,CALL,SEND:Pump failure
Example:
1111 TIME:1115:O1ON