Sag-voltage payload will be sent in Port 10.

 

 

 

 

Timestamp: 

Standard UTC time. 

 

Time zone: 

It is a signed number, convert to decimal, then then divide by 2, and this is UTC 

time zone; 

 

Sag-voltage state: 

01 means sag-voltage state. 

 

Currents instantaneous voltage: 

Convert to decimal, then divide by 10, the unit is V.  

 

Sag-voltage threshold: 

Convert to decimal, then divide by 10, the unit is V. 

 

7.6 Over-current Payload  

 

Over-current payload will be sent in Port 11.

 

 

 

 

Timestamp: 

Standard UTC time. 

 

Time zone: 

It is a signed number, convert to decimal, then then divide by 2, and this is UTC 

time zone; 

 

Over-current state: 

01 means over-current state. 

 

Currents instantaneous current: 

Convert to decimal, then divide by 1000, the unit is mA.  

 

Over-current threshold

Convert to decimal, then divide by 1000, the unit is mA. 

 

7.7 Over-load Payload  

 

Over-load payload will be sent in Port 12.

 

 

 

 

Timestamp: 

Standard UTC time. 

 

Time zone: 

It is a signed number, convert to decimal, then then divide by 2, and this is UTC 

time zone; 

 

Over-load state: 

01 means over-load state. 

 

Currents instantaneous power: 

Convert to decimal, then divide by 10, the unit is W.  

 

Over-load threshold

Convert to decimal, then divide by 10, the unit is W. 

 

7.8 Load State Payload  

Byte 0~3 

Byte 4 

Byte 5 

Byte 6~7 

Byte 8~9 

Timestamp 

Time zone 

Sag-voltage state 

Currents instantaneous 
voltage 

Sag-voltage threshold 

Byte 0~3 

Byte 4 

Byte 5 

Byte 6~7 

Byte 8~9 

Timestamp 

Time zone 

Over-current state 

Currents instantaneous 
current 

Over-current threshold 

Byte 0~3 

Byte 4 

Byte 5 

Byte 6~8 

Byte 9~10 

Timestamp 

Time zone 

Over-load state 

Currents instantaneous 
power 

Over-power threshold 

Summary of Contents for LW005-MP

Page 1: ...Datasheet LW005 MP Product Specification MOKO TECHNOLOGY LTD Version 1 0 www mokosmart com Version 1 0 ...

Page 2: ...Control 9 6 5 Electrical Monitoring 9 6 6 Energy Monitoring 10 6 7 Power Consumption Indicator 10 6 8 Over voltage Sag voltage Over current Over load Protection 10 6 9 Load Work State Detection 10 6 10 Restore to Factory Setting 10 6 11 Default Power Status 11 6 12 Bluetooth Configuration Tool 11 6 12 1 Advertising packet 11 6 12 2 Response packet 11 7 Uplink Payload 12 7 1 Switch Payload 12 7 2 E...

Page 3: ...ontrol industrial equipment monitoring power monitoring and energy management etc 1 2 Model List LW005 MP series contains several product models the model list is as below Model Description LW005 MP B US type max current is 15A US915 Default Frequency LW005 MP G UK type max current is 13A EU868 Default Frequency LW005 MP F EU type max current is 16A EU868 Default Frequency LW005 MP E FR type max c...

Page 4: ...work and switch state separately FCC UL CE certified 3 Application Scenarios Scenario 1 Intelligent industrial control LW005 MP can be used for electrical energy monitoring and remote control of some key industrial equipment It can report the electrical parameters voltage current power and total electrical energy data during the operation of the equipment Data analysis can be generated on the serv...

Page 5: ...r consumption of some frequently used office equipment or electrical appliances The plug can automatically power on the electrical devices on working hours and turn off on the working off hours It also uploads the power consumption data of the load to the server in real time the server can generate data analysis to find out the equipment with abnormal power consumption quickly and limit the use wh...

Page 6: ...ation of the device can influence the radio performance For optimum results keep the zone around the antenna area clear from any conducting material or magnetic fields 4 2 Dimensions 4 3 LED Patterns Indicator Action LED Patterns Network Indicator Connect to network server successfully Solid White ...

Page 7: ...23 IN865 KR920 EU433 C N470 CN779 RU864 Tx Power Max 21dBm Sensitivity 137dBm SF12 300bps LoRa Communication Distance Up to 7 km in urban open space BLE Wireless Specification Bluetooth BLE V4 0 TX Power Max 4 dBm The device is connecting to network server Flash blue once per second Start network check each time Flash green one second each time Switch Indicator Switch ON The color depends on the a...

Page 8: ...smission Strategy Considering the load balance of the gateway the battery power consumption and the reliability of the messages the LW005 MP is equipped with a LoRa uplink mechanism for users to choose so that users can select a suitable sending strategy according to different application scenarios 6 1 2 Confirmed Message Retransmission Mechanism Because the application scenario of this product re...

Page 9: ...please check the instructions in LW005 MP APP guide 6 3 ON OFF Monitoring Control There are three ways to control the AC output of the plug Through the physical button click the button once to switch the ON OFF state Through the MKLoRa APP Through LoRaWAN downlink command The device will regularly report Switch Payload for ON OFF monitoring after connect to LoRaWAN network server successfully In a...

Page 10: ...load Over current Payload Over load Payload to LoRaWAN server Over voltage protection When the plug detects that the measured voltage exceeds the over voltage threshold for a period of time it will automatically turn off Sag voltage protection When the plug detects that the measured voltage lows the sag voltage threshold for a period of time it will automatically turn off Over current protection W...

Page 11: ...via Bluetooth connection About the detail of MKLoRa pls refer to LW005 MP APP Guide The Bluetooth broadcast contents of LW005 MP are divided into advertising packet and response packet The following is an example of the broadcast content 6 12 1 Advertising packet LEN TYPE VALUE 2 0x01 0x 06 4 0x16 0x 04 AA 00 14 0x09 0x 4C 57 30 30 35 2D 4D 50 2D 35 43 33 42 Service UUID LW005 MP 0x 04 AA Device A...

Page 12: ...h Payload Switch payload will be sent in Port 5 Timestamp Standard UTC time Time zone It is a signed number convert to decimal then then divide by 2 and this is UTC time zone AC output state 00 means that AC output of plug is OFF 01 means that AC output of plug is ON Plug load status 01 means there is a load on the plug 00 means no load on the plug 7 2 Electrical Payload This payload will be sent ...

Page 13: ...ide by 3200 the unit is KW H This is the energy data of the last hour for example if the reported time is 14 23 the total ebergy data of the hour from 13 00 to 14 00 will be reported 7 4 Over voltage Payload Over voltage payload will be sent in Port 9 Timestamp Standard UTC time Time zone It is a signed number convert to decimal then then divide by 2 and this is UTC time zone Over voltage state 01...

Page 14: ...vide by 1000 the unit is mA Over current threshold Convert to decimal then divide by 1000 the unit is mA 7 7 Over load Payload Over load payload will be sent in Port 12 Timestamp Standard UTC time Time zone It is a signed number convert to decimal then then divide by 2 and this is UTC time zone Over load state 01 means over load state Currents instantaneous power Convert to decimal then divide by ...

Page 15: ...wn payload will be sent in Port 14 Timestamp Standard UTC time Time zone It is a signed number convert to decimal then then divide by 2 and this is UTC time zone ON OFF state after countdown process ends 00 means OFF 01 means ON Time remaining of the countdown process Convert to decimal the unit is S second Byte 0 3 Byte 4 Byte 5 Timestamp Time zone Change of load state Byte 0 3 Byte 4 Byte 5 Byte...

Page 16: ...re can form inside the device and damage the device or battery Do not drop knock or shake the device Rough handing would break it Do not use strong chemicals or washing to clean the device Do not paint the device paint would cause improper operation Do not disassemble the device casually or use the tools for maintenance without permission Handle your device battery and accessories with care The su...

Page 17: ...LW005 MP MOKO TECHNOLOGY LTD 4F Buidling2 Guanghui Technology Park MinQing Rd Longhua Shenzhen Guangdong China Tel 86 755 23573370 829 Support_lora mokotechnology com https www mokosmart com ...

Reviews: