4.9.2.4. Periodical test cycle programming
To configure the frequency with which GSR will run the test must be used the following SMS:
12345,S:$ci:minutes_between_each_test
Response:
[“OK”]
Standard value is set to 4320 minutes that represents
3 days
as
EN81-28 regulation
specifies.
4.9.2.5. Recall attempts programming
The number of recall attempts can be set with the following SMS:
12345,S:$mda:number_of_recall_attempts
Response:
[“OK”]
4.9.2.6. Alarm validation command programming
To configure the DTMF tones that the device will accept as
alarm validation
(ACK) must be sent the
following SMS:
12345,S:$ackdtmf:“alarm_validation_command”
Response:
[“OK”]
4.9.2.7. Emergency button press time programming
To set the time that the emergency button of each elevator car must be pressed to generate an
outcoming call, use the following SMS where X stands for the number of the elevator car (1-4):
12345,S:$abpsX:time_in_seconds
Response:
[“OK”]
4.9.2.8. Emergency button logic programming
To set the emergency button logic of each elevator car individually send:
Nayar Systems
GSR - 1_en