Getting Started with MAXserver Access Servers
0038
40
c.
Configure the Subnet Mask for the access server. The subnet mask
must be consistent with the network on which the access server
will reside. Use the following commands:
define server ip subnet mask [ip-address]
set server ip subnet mask [ip-address]
d.
Configure the default first-hop Router/Gateway:
define server ip primary gateway address [ip-address]
set server ip primary gateway address [ip-address]
2.
Specify Telnet Port 2000 when connecting remotely:
Be sure to specify telnet remote port# 2000 when trying to connect. If no
port/socket number is specified, then most Telnet applications will use
port 23 by default. Unless the Xyplex's console port has also been
redefined to port 23, then any attempts to Telnet into the server's
console port will be refused.
The current port setting on the access server is displayed in the “Remote
Port” field of the “show port 0 telnet characteristics” screen. Figure 11
shows a “show port 0 telnet characteristics” screen with the “Remote
Port” field set at 2000.
MX1620>> show port 0 telnet characteristics
Port 0: admin 05 Jan 2000 19:33:48
Abort Output Character: None Newline: CR/NULL
Attention Character: None Newline Filtering: None
Default Port: 23 Query Character: None
Echo Mode: Character Remote Port: 2000
Erase Keystroke Character: None Synchronize Character: None
Erase Line Character: None Transmit: BuffTime 80
Interrupt Character: None Binary Session Mode: PASTHRU
TerminalType: None Tn3270 Device: None
Tn3270 TranslationTable: None Tn3270 Printer Port: Any
Local Port: 4000 Tn3270 Default Port: 23
Enabled Characteristics:
Figure 11 - Sample SHOW PORT 0 TELNET CHARACTERISTICS Display