MAX Command Reference Guide
FXS Configuration Commands
62
; cid
- on|off
; t1
- 150 ~ ms
; t2
- 300(960) ~ 3000ms (<960:in hook flash disabled)
; t3
- 0(300) ~ 960ms (0:disable hook flash)
; t4~5
- 1 ~ 30 sec
; t6
- 1 ~ 100 sec
; t7
- 30 ~ 200 sec
======================================================================
[Parameter description]
Parameter
Description
Ron
Ring Cadence On time
(1~4 ) sec
Roff
Ring Cadence Off time
(1~4 ) sec
Rfreq
Ring Frequency
(20 ~ 30) Hz
Pola
Selection on polarity reversion (Y, N)
Vgain
Voice energy sent to the FXS interface.
(-31 ~ 31)dbm
Igain
Voice energy received from
the FXS interface. (-31 ~
31)dbm
dtype
Set up sending dial tone type
cid
Set up caller id send on or off
t1
Off-Hook guard time
(150~ ) msec
t2
On-Hook guard time
300(960)~3000msec.
in hook flash disabled : setup less than 960.
t3
Hook-flash time
0(300)~960 msec.
0: disable hook flash
t4
Maximum time to detect the first digit after off-hook.
(1 ~ 30) sec
t5
Maximum time to wait for the second digit after the
first digit.
(1 ~ 30) sec
t6
Generation duration of release tone. (1 ~ 100) sec
t7
Generation duration of ringback tone. (30 ~ 200) sec
[Example] Setup the RING CADENCE ON time with 1 sec.
SYS_NAME
:/CONFIG/FXS> change ron 1
Configuration is not saved. You must save the changed configurations
Command successfully end.
SYS_NAME
:/CONFIG/FXS> ../save
This command isn’t recoverable. Are you sure (y/n) ?
y
Configurations in working memory is saved to NV-Memory.