Communication, Counter and Pulse
SECTION 4
12 to 15
End code selection for no-protocol communications
0: Disables end code; 1: Enables end code in DM 6649; 2: Sets end code of CR, LF.
(Any other setting disables the end code, causes a non-fatal error, and turns ON AR 1302.)
Word(s) Bit(s)
Function
00 to 07
Start code (00 to FF)
(This setting is valid only when bits 8 to 11 of DM 6648 are set to 1.)
DM 6649
08 to 15
When bits 12 to 15 of DM 6648 set to 0:
Sets the number of bytes to receive. (00: 256 bytes; 01 to FF: 1 to 255 bytes)
When bits 12 to 15 of DM 6648 set to 1:
Sets the end code. (00 to FF)
4-1-2
Peripheral RS-422/485 Port Communications Settings
The following settings are effective after transfer to the PLC.
If the 3G3MV-P10CDT Unit’s Communications Switch is ON, communica-
tions through the peripheral port are governed by the default settings (all 0)
regardless of the settings in DM 6650 through DM 6654.
The 3G3MV-P10CDT’s Communications Switch setting has no effect on
communications with a Programming Console connected to the peripheral
port or Support Software set for peripheral bus communications. The
3G3MV-P10CDT Unit will auto-detect either Programming Device and auto-
matically establish communications.
Word(s) Bit(s)
Function
00 to 03
Port settings
0: Standard (1 start bit, 7 data bits, even parity, 2 stop bits, 9,600 bps), Host Link unit
number:
0
1: Settings in DM 6651
(Any other setting will cause a non-fatal error and AR 1302 will turn ON.)
04 to 11
Not used.
DM 6650
12 to 15
Communications mode
0: Host Link or peripheral bus; 1: No-protocol
(Any other setting causes a non-fatal error and turns ON AR 1302.)
00 to 07
Baud rate
00: 1,200 bps; 01: 2,400 bps; 02: 4,800 bps; 03: 9,600 bps; 04: 19,200 bps
DM 6651
08 to 15
Frame format
Start bits
Data bits
Stop bits Parity
00:
1 bit
7 bits
1 bit
Even
01:
1 bit
7 bits
1 bit
Odd
02:
1 bit
7 bits
1 bit
None
03:
1 bit
7 bits
2 bits
Even
04:
1 bit
7 bits
2 bits
Odd
05:
1 bit
7 bits
2 bits
None
06:
1 bit
8 bits
1 bit
Even
07:
1 bit
8 bits
1 bit
Odd
08:
1 bit
8 bits
1 bit
None
09:
1 bit
8 bits
2 bits
Even
10:
1 bit
8 bits
2 bits
Odd
11:
1 bit
8 bits
2 bits
None
(Any other setting specifies standard settings (1 start bit, 7 data bits; even parity, 2 stop
bits, 9,600 bps), causes a non-fatal error, and turns ON AR 1302.)
40
Summary of Contents for 3G3MV-P10CDT-E
Page 2: ...3G3MV P10CDT PLC Option Unit User s Manual Revised June 2003 ...
Page 38: ...Unit Components and Specifications SECTION 2 2 1 4 Dimensions 68 128 55 25 ...
Page 43: ......
Page 85: ...Example Programs Appendix B 72 ...
Page 86: ...Example Programs Appendix B 73 ...
Page 87: ...Example Programs Appendix B 74 ...
Page 88: ...Example Programs Appendix B 75 ...
Page 90: ...Example Programs Appendix B 77 ...
Page 91: ...Example Programs Appendix B 78 ...
Page 97: ...Example Programs Appendix B B 4 9 Programs User_Parameter_Init 84 ...
Page 98: ...Example Programs Appendix B 85 ...
Page 99: ...Example Programs Appendix B User_Application Pos_Loop 86 ...
Page 100: ...Example Programs Appendix B 87 ...
Page 101: ...Example Programs Appendix B 88 ...
Page 102: ...Example Programs Appendix B 89 ...
Page 103: ...Example Programs Appendix B 90 ...
Page 104: ...Example Programs Appendix B 91 ...
Page 105: ...Example Programs Appendix B 92 ...
Page 106: ...Example Programs Appendix B 93 ...
Page 107: ...Example Programs Appendix B Pos_Home_Sequence 94 ...
Page 108: ...Example Programs Appendix B 95 ...
Page 109: ...Example Programs Appendix B 96 ...