background image

Thank you for purchasing a Panasonic Pure IP-PBX.
Please read this manual carefully before using this product and save this manual for future use.

KX-NCP500/KX-NCP1000: PBMPR Software File Version 2.0200 or later

Document Version: 2009-12

Pure IP-PBX

PC Programming Manual

Model No.        

KX-NCP500

KX-NCP1000

Summary of Contents for KX-NCP500

Page 1: ... Please read this manual carefully before using this product and save this manual for future use KX NCP500 KX NCP1000 PBMPR Software File Version 2 0200 or later Document Version 2009 12 Pure IP PBX PC Programming Manual Model No KX NCP500 KX NCP1000 ...

Page 2: ...ual References The Feature Manual explains what the PBX can do as well as how to obtain the most of its many features and facilities Sections from the Feature Manual are listed throughout this manual for your reference Installation Manual References The Installation Manual provides instructions detailing the installation and maintenance of the PBX Sections from the Installation Manual are listed t...

Page 3: ...t Windows and Windows Vista are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries All other trademarks identified herein are the property of their respective owners Microsoft product screen shot s reprinted with permission from Microsoft Corporation NOTES The contents of this manual apply to PBXs with a certain software version as indic...

Page 4: ...lose 35 2 3 2 File Save 35 2 3 3 File Save As 35 2 3 4 File Exit 35 2 4 Disconnect 36 2 4 1 Disconnect Disconnect 36 2 5 Tool 37 2 5 1 Tool SD memory backup 37 2 5 2 Tool NDSS Link Data Clear 37 2 5 3 Tool DXDP All OUS 37 2 5 4 Tool Simplified Voice Message Delete All Recording 37 2 5 5 Tool Simplified Voice Message Check Current Usage 37 2 5 6 Tool Call Pickup for My Group 38 2 5 7 Tool Extension...

Page 5: ...1 Slot Shelf Property Virtual IP Gateway DN2IP 150 3 13 1 1 Slot Shelf Property Virtual IP Gateway Hunt Pattern 153 3 14 1 1 Slot Card Property Virtual IP Extension 155 3 15 1 1 Slot Port Property Virtual IP Extension 163 3 16 1 1 Slot Port Property Virtual IP Extension Connection Command 173 3 17 1 1 Slot Card Property Virtual SIP Extension 174 3 18 1 1 Slot Port Property Virtual SIP Extension Po...

Page 6: ...1 2 11 2 Audio Gain Card 449 5 3 Group 451 5 1 3 1 1 Trunk Group TRG Settings 452 5 2 3 1 2 Trunk Group Local Access Priority 459 5 3 3 1 3 Caller ID Modification 460 5 4 3 1 4 Dialing Plan 465 5 5 3 1 4 Dialing Plan Auto Assign 467 5 6 3 2 Extension Group 468 5 7 3 3 Call Pickup Group 470 5 8 3 3 Call Pickup Group All Setting 472 5 9 3 4 Paging Group 473 5 10 3 4 Paging Group All Setting 475 5 11...

Page 7: ... Send 679 6 16 4 2 5 Portable Station Simplified Voice Message 680 6 17 4 3 DSS Console 682 6 18 4 3 DSS Console DSS key data copy 700 7 5 Optional Device 701 7 1 5 1 Doorphone 702 7 2 5 2 External Pager 706 7 3 5 3 1 Voice Message DISA System 708 7 4 5 3 2 Voice Message DISA Message 717 7 5 5 3 3 Voice Message SVM 720 7 6 5 4 External Relay 725 7 7 5 5 External Sensor 728 8 6 Feature 731 8 1 6 1 ...

Page 8: ...ame Generate 802 12 6 10 4 Miscellaneous 805 13 11 Maintenance 807 13 1 11 1 Main 808 13 2 11 2 PT Programming Access 831 13 3 11 3 Power Failure Transfer 832 13 4 11 4 1 SNMP System Setting 833 13 5 11 4 2 SNMP Manager 836 13 6 11 5 Air Synchronization 840 14 Appendix 847 14 1 Revision History 848 14 1 1 KX NCP500 KX NCP1000 PBMPR Software File Version 1 01xx 848 14 1 2 KX NCP500 KX NCP1000 PBMPR...

Page 9: ...Section 1 Overview This section provides an overview of programming the PBX Document Version 2009 12 PC Programming Manual 9 ...

Page 10: ...gramming mode will be denied access Ways to Program There are two programming methods PC Personal Computer Programming All features and settings of the PBX can be programmed through PC programming with Maintenance Console Installing and starting the Maintenance Console is described in Section 1 2 PC Programming Individual PC programming items are described in Section 2 Introduction of Maintenance ...

Page 11: ...a white background below can be used when storing a name message password or other text entry data using a PC The available characters vary according to the model of PBX Document Version 2009 12 PC Programming Manual 11 1 1 2 Entering Characters ...

Page 12: ...e logged in as a user in the Administrators group 1 Copy the setup file of the Maintenance Console to your PC 2 Double click the setup file to run the installer 3 Follow the on screen instructions provided by the installation wizard Starting the Maintenance Console and Assigning the Basic Items Quick Setup When you start the Maintenance Console with the Installer Level Programmer Code and connect ...

Page 13: ...r entered manually Note If you change any information on this screen and click Apply the PBX will need to be reset When using a DHCP server a Select Enable for the DHCP Client setting b Click Apply Note The boxes will turn grey and the IP addresses will be assigned automatically after the PBX is reset When not using a DHCP server a Select Disable for the DHCP Client setting b In the IP Address for...

Page 14: ...N and then connect the PC with an Ethernet straight cable using 192 168 0 101 for the IP address of the IPCMPR card 1 Valid IP address range 1 0 0 0 to 223 255 255 255 2 Valid IP address range 1 0 0 0 to 223 255 255 255 3 Valid subnet mask address range 0 255 0 255 0 255 0 255 except 0 0 0 0 and 255 255 255 255 4 Valid IP address range 0 0 0 0 to 223 255 255 255 PBX Web Manager It is possible to u...

Page 15: ...t the login screen input the PBX s IP address port and password Any profiles using LAN connection that have been saved when accessing the Maintenance Console directly will be automatically displayed for easy access to your PBX 3 Click Connect PBX Web Manager Main Menu After successful login the main menu will appear where settings can be changed Note While logged in if there is no activity for app...

Page 16: ...void unauthorized access and possible abuse of the PBX keep the passwords secret and inform the customer of the importance of the passwords and the possible dangers if they become known to others 3 The PBX has default passwords preset For security change these passwords the first time that you program the PBX 4 Change the passwords periodically 5 It is strongly recommended that passwords of 10 num...

Page 17: ...n 2 Introduction of Maintenance Console This section serves as reference operating instructions when using the Maintenance Console software to program the PBX Document Version 2009 12 PC Programming Manual 17 ...

Page 18: ... To start Maintenance Console in Interactive mode 1 Enter the relevant programmer code 2 Click OK The program launcher will appear 3 Click Connect Connection options will be displayed Select a Profile Name if you want to use a pre saved profile This option is only available when one or more profiles have been previously stored a Select the profile to use from the drop down list b If the system pas...

Page 19: ... connected telephone Comment Max 40 characters Enter a comment to identify the set of values Port COMx Specify the number of the COM port assigned to the PC s modem interface Only available COM ports will be displayed Baud Rate bps 1200 2400 4800 9600 19200 38400 Specify the speed of data transmission Modem Initialize Enter the modem initialize command and click Initialize to send the command to t...

Page 20: ... software mode see 2 1 1 Starting Maintenance Console and Software Modes When a menu option is limited to certain access levels this is noted in this manual in the initial description of that menu option for example This option is only available at Installer level If a sentence like this does not appear under the heading the menu option is available at all levels The target users for each access l...

Page 21: ...U A I Disconnect ü ü ü Tool Menu Option Batch Interactive U A I U A I SD memory backup ü ü ü NDSS Link Data Clear ü DXDP All OUS ü Simplified Voice Message Delete All Recording ü Simplified Voice Message Check Current Usage ü Call Pickup for My Group ü ü Extension List View ü ü ü ü ü ü Import Feature Speed Dial and Caller ID ü ü ü ü ü ü Import Incoming Call DID Table ü ü Import ARS Leading Digit ü...

Page 22: ...ept Code ü ü Export ARS Routing Plan ü ü Export Wired Extension ü ü Export PS Extension ü ü Export Quick Dial Basic ü ü Export Quick Dial Expansion ü ü Export SIP Extension ü ü Export V IPGW16 GW Settings ü ü Export V IPGW16 DN2IP ü ü Screen Customize User Level ü ü Screen Customize Administrator Level ü ü Utility Menu Option Batch Interactive U A I U A I Diagnosis ü ü ü File Transfer PC to PBX SD...

Page 23: ... ü File Transfer FTP to IP Equipment IP CS ü File Transfer FTP to IP Equipment NT400 ü File Transfer FTP to IP Equipment NT3xx ü Card Software Timed Update ü System Reset Reset by the Command ü Flash ROM ID Information ü View Menu Option Batch Interactive U A I U A I Toolbar ü ü ü ü ü ü Statusbar ü ü ü ü ü ü System Menu ü ü ü ü ü ü Window Menu Option Batch Interactive U A I U A I Cascade ü ü ü ü ü...

Page 24: ...p ü ü ü ü ü ü Additional Information ü ü ü ü ü ü About ü ü ü ü ü ü 2 1 3 Software Interface This section explains the functions of the various elements of the software interface 24 PC Programming Manual Document Version 2009 12 2 1 3 Software Interface ...

Page 25: ...ions as well as tools and utilities used in programming the PBX For details see Sections 2 2 Program launcher to 2 7 Help 2 Tool Bar Provides easy access to commonly used software functions Two tool bars are provided as follows File Contains the icon for saving files For details see Section 2 3 2 File Save Document Version 2009 12 PC Programming Manual 25 2 1 3 Software Interface ...

Page 26: ...below This menu can be positioned freely Click and drag the title bar of the menu to move it to another position It will automatically snap in to either the left side or right side of the main window if released there Otherwise it will float separately from the main window Whether the system menu is displayed or not can be chosen by selecting System Menu from the View menu 5 Status Bar The status ...

Page 27: ...ll open folder icon beside lists of setting items Clicking this icon will collapse part of the list allowing other items to be displayed The icon will change to a closed folder Clicking the closed folder icon will expand the list again 2 1 4 Card Status Certain tools utilities and settings require that the target card be set to out of service OUS or in service INS status before the operation is ca...

Page 28: ... accessed by clicking a button This section explains how to use this Extension Number Setting window To select multiple extension numbers select the type of extension to display highlight the extensions you wish to add then click the Add button When finished click OK Data for the selected extensions will be added to the first free spaces on the original screen Extension Type Selects the types of e...

Page 29: ...by deselecting that field here To select or deselect a field click its name Default First available field Value Range Available fields Selected Extension List Displays the extensions that have been selected to be added to member data To remove an extension from this list click it to select it and click Delete Default Not stored Value Range Selected extensions Document Version 2009 12 PC Programmin...

Page 30: ...y the PBX e g a system data file from an incompatible PBX it will not be opened The only files that can be opened are files that were created by the Maintenance Console for a supported PBX To upload a file opened here to the SD memory card installed in the PBX see 2 6 2 Utility File Transfer PC to PBX SD Card To open a system data file 1 From the program launcher select Open The Open dialog box wi...

Page 31: ...OMx Specify the number of the COM port assigned to the PC s RS 232C interface Only available COM ports are displayed Baud Rate bps 2400 4800 9600 19200 38400 57600 115200 Specify the speed of data transmission 2 2 4 Program launcher Connect USB Connects to the PBX in Interactive mode through a USB port USB Module attached to the KX DT300 series or KX T7600 series DPT To connect to the PBX by USB 1...

Page 32: ...hat was input in IP Address for IPCMPR Card of 3 4 1 1 Slot Card Property IPCMPR Port Number 1 65535 Specify the port number used to access the PBX via LAN Enter the same port number that was input in Maintenance Port Number of 3 4 1 1 Slot Card Property IPCMPR 2 2 6 Program launcher Connect Modem Connects to the PBX in Interactive mode through the modem To access the PBX remotely using this featu...

Page 33: ...itialize to send the command to the modem For more details refer to your modem s instruction manual 2 2 7 Program launcher Connect Profile Setup Profiles are useful when one PC is used to connect to multiple PBXs Rather than manually adjusting the connection settings each time a different PBX is accessed it is possible to store the connection settings for several PBXs Then when you wish to connect...

Page 34: ...tion Delete profile When an existing profile is selected deletes that profile A confirmation message will be displayed 34 PC Programming Manual Document Version 2009 12 2 2 7 Program launcher Connect Profile Setup ...

Page 35: ...rogram launcher Connect LAN 2 3 3 File Save As Saves the system data file being modified in Batch mode with the name chosen by the user To upload a file saved here to the SD memory card installed in the PBX see 2 6 2 Utility File Transfer PC to PBX SD Card To save a system data file with a new name 1 From the File menu select Save As 2 Navigate to the folder in which you want to save the file 3 En...

Page 36: ...his option is chosen system data is automatically backed up from the PBX to the SD memory card see 2 5 1 Tool SD memory backup To disconnect 1 From the Disconnect menu select Disconnect A confirmation message will be displayed 2 Click Yes 36 PC Programming Manual Document Version 2009 12 2 4 1 Disconnect Disconnect ...

Page 37: ...en 2 5 3 Tool DXDP All OUS Sets the status of all DXDP XDP extension ports to OUS simultaneously To set all DXDP XDP ports to OUS 1 From the Tool menu select DXDP All OUS 2 Click OK 2 5 4 Tool Simplified Voice Message Delete All Recording Deletes all voice messages recorded by the SVM feature To delete voice messages 1 From the Tool menu point to Simplified Voice Message and select Delete All Reco...

Page 38: ...er has been assigned The Personal Speed Dialing feature number has been assigned 2 5 7 Tool Extension List View Displays a list of all programmed extension numbers and types It is possible to sort the information according to Extension Number Type Extension Name Shelf Slot or Port There is also a key word searching feature The types that can be displayed are as follows Type Detail Intercom Wired E...

Page 39: ...ure Speed Dial and Caller ID Data Type Import Destination System Speed Dialing Number Location Name Name CO Line Access Number Telephone Number Dial CLI Destination CLI Destination Related programming 8 1 6 1 System Speed Dial Incoming Call DID Table Data Type Import Destination Location Location DID Number Dial In Number DID Name Dial In Name DID Destination Day Destination Day DID Destination Lu...

Page 40: ...ct no fields to select Related programming 10 3 8 3 Routing Plan Time Wired Extension Data Type Import Destination No Location selected automatically Extension Number Extension Number selected automatically Extension Name Extension Name selected automatically Related programming 6 1 4 1 1 Wired Extension Extension Settings PS Extension Data Type Import Destination No Location selected automaticall...

Page 41: ...ion Extension Number Extension Number Password Password Related programming 3 18 1 1 Slot Port Property Virtual SIP Extension Port V IPGW16 GW Settings Data Type Import Destination No Location GW Name GW Name GW IP Address GW IP Address GW Group GW Group No Connection for IP GW16 Connection for IP GW16 Protocol Protocol Progress Tone Send Mode Progress Tone Send Mode IP Codec Priority 1st IP Codec...

Page 42: ... will be displayed 5 For the Feature Speed Dial and Caller ID table select the Speed Dial table to which to import the data system or tenant from the drop down list 6 If required select import fields When import fields can be selected the selection screen is displayed automatically Matching origin and destination fields are entered by default To change the destination for an import field select th...

Page 43: ...and Caller ID table select the Speed Dial table from which to export the data system or tenant from the drop down list A list of field names that can be exported will be displayed 6 Click the check box beside the name of each field that you want to export 7 Click OK 2 5 10 Tool Screen Customize User Level Administrator Level Allows you to specify which menu screens tools and utilities can be acces...

Page 44: ...est port DHLC SLC PT loop back diagnosis DHLC DLC DSP DTMF generator receiver diagnosis T1 DSP DTMF receiver diagnosis T1 Framer IC alarm signal detection diagnosis T1 PRI Framer IC error detection diagnosis T1 PRI Caller ID card loop back diagnosis LCOT To perform a card test 1 From the Utility menu select Diagnosis 2 Click on the Status cell of the card to be tested and set it to OUS 3 Click on ...

Page 45: ...les can be copied using this tool Program files These contain the programs used to operate cards within the PBX and CSs acting as on board drivers Data files These contain the initial configuration data for individual cards and settings Activation Key files These contain the activation keys used to enable the use of IP CO lines and IP telephones through Virtual VoIP cards and upgrade the software ...

Page 46: ...High density CS for DECT Portable Station PDCS24G CS using a DHLC DLC card for 2 4 GHz Portable Station System Data Name on SD Memory Card Corresponding Card DBSYS IPCMPR DBSYS_S IPCMPR 1 1 DBSYS file format data that is transferred to the PBX is saved as DBSYS_S Language Data Name on SD Memory Card Corresponding Unit DLNG0 DLNG1 PT DVMLNG1 DVMLNG5 VPS Display Guidance data Activation Key Name on ...

Page 47: ...s to the SD memory card the PBX automatically renames them according to the header information A message will be displayed when the transfer is complete 3 Click OK 2 6 3 Utility File Transfer PBX SD Card to PC Copies system data files from the SD memory card installed in the PBX to the connected PC This option is only available at Installer level The files that can be downloaded from the SD memory...

Page 48: ...e set to OUS but the card itself must be set to in service INS Only cards that are in the correct status will be displayed The name date and time of creation and size of files are displayed This utility can also display information on activation key files stored in the SD memory card The effective date IPCMPR ID activated feature type number of activated features and expiration date of activation ...

Page 49: ...ock mounted on an OPB IPCMPR card This option is only available at Installer level Note When transferring to or from an MSG ESVM card mounted on an OPB card the OPB card must be set to OUS status When transferring to or from the built in ESVM block on the IPCMPR card the ESVM block must be set to OUS status Files are stored on the MSG ESVM card block in the location specified by the file s header ...

Page 50: ...d as an individual file with a number appended to the file name corresponding to that message s location on the MSG ESVM card block When complete the display will return to the main screen 2 6 8 Utility Error Log Collects and displays system error information Whenever there is a system failure the PBX stores the error code generated The connected PC collects all of these codes along with other inf...

Page 51: ... displayed as follows Sub slot 1 of OPB3 11 to 14 Sub slot 2 of OPB3 21 to 24 Sub slot 3 of OPB3 31 to 34 Note When there is no parameter for slot and port number YY and ZZ will be displayed as 00 Example Sub code for IPCMPR card 10000 Error Message A description of the error To view the error log From the Utility menu select Error Log 2 6 9 Utility T1 Signaling Bit Monitor Displays reference sign...

Page 52: ...s a text format file Click Clear to erase the information 2 6 11 Utility ISDN QSIG Protocol Trace This utility collects protocol trace data from PRI cards and displays it on the PC This option is only available at Installer level and requires that the target PRI card be set to INS status Protocol trace data is continually accumulated on ISDN cards and 3 types of data can be downloaded Real Time Tr...

Page 53: ...ous types of errors occurring on digital CO lines This option is only available at Installer level The value displayed for each error item is the number of times that each error occurred during the time period selected Average values for these items vary depending upon many factors such as the equipment being used and the distance from the telephone company The displayed items are as follows Item ...

Page 54: ...kets lost RTP Receive Abandoned Packet Counter Total number of packets abandoned RTP Arrive Packet Interval MAX ms Maximum time taken for a packet to arrive RTP Arrive Packet Interval MIN ms Minimum time taken for a packet to arrive To view IP extension information 1 From the Utility menu select IP Extension Statistical Information 2 From the Card Selection drop down list select the slot number fo...

Page 55: ...PSs registered to the attached CS that are members of a PS Ring Group To view CS information 1 From the Utility menu select CS Information 2 From the Target CSI F Slot No drop down list select the target slot To display information on a single card select the slot number and name of that card To display information on all matching cards select All 3 From the Interval Timer drop down list select th...

Page 56: ...at each CS is currently synchronized with Slot Slot number of the CS that each CS is currently synchronized with Port Port number of the CS that each CS is currently synchronized with CS Repeater Indicates whether the CS that each CS is currently synchronized with is a CS or Repeater CS Name Name of the CS that each CS is currently synchronized with CS ID 12 digit ID number of the CS that each CS ...

Page 57: ... IP Equipment IP CS NT400 Displays a list of files on the FTP server and allows you to update the programs stored in IP CSs and KX NT400 IP PTs This option is only available at Installer level It is possible to perform the update in 2 ways Manual update Timed automatic update To update manually 1 From the Utility menu select File Transfer FTP to IP Equipment and then either IP CS or NT400 2 Input ...

Page 58: ...re Timed Update Updates programs in the LPR cards optional service cards with local processors by comparing them with files found on the SD memory card on a preset schedule and downloading newer files to the cards This option is only available at Installer level Note Timed updates can only be set for either LPR cards IP CSs or KX NT400 IP PTs They cannot be set for more than one type of device Car...

Page 59: ...BX This option is only available at Installer level Two copies of each of the main system files can be stored on the SD memory card The names of these files are as follows File Name Description DBSYS Main system data file Contains all of the current configuration data for the PBX DBSYS_S Backup main system data file PBMPR PBX program file Contains the software to run the IPCMPR board of the PBX PB...

Page 60: ... reset the PBX If OK is clicked a final confirmation screen will be displayed Click Cancel to return to the main screen without copying files 6 Click OK to reset the PBX or Cancel to return to the main screen without copying files If the reset command was not carried out correctly an error message will be displayed and you will be returned to the main screen After resetting the PBX with this comma...

Page 61: ...uses correctly specified Is the baud rate correct The default setting and a safe rate is 19 200 bps Is the password correct Is the Maintenance Console not connected to the PBX by another connection method Q The Maintenance Console cannot connect to the PBX via USB A Is the USB cable firmly connected to both the PC and the KX DT300 series KX T7600 series DPT with a USB Module Is the USB driver on t...

Page 62: ...n is too narrow A Move the mouse to the line between the names of 2 setting items at the top of the table The pointer will change to a double arrow Click and drag the line to the right until all characters are displayed Card Status Q The status of a new card will not change to INS A With the new card installed does the total number of extensions or CO lines exceed the maximum supported by the PBX ...

Page 63: ...on Is the Portable Station within transmission range of the CS If not move it closer to the CS and try the de registration operation again Q The Portable Station I want to de register is broken and will not turn on or is not available or the registration information was deleted first from the Portable Station so it cannot be de registered A The Portable Station can be forcibly de registered by fol...

Page 64: ...or change No of Additional Digits from x to xx For more details see What is the procedure to modify the Numbering Plan in Numbering Q How do I set a 3 digit numbering plan A There are 2 methods of creating a 3 digit numbering plan using 4 9 2 6 1 Numbering Plan Main 1 Set the leading number to be 2 digits with one additional digit This method allows a maximum of 10 extensions Example Leading Numbe...

Page 65: ...p with another Leading Number So for example if 2 is already set as a Leading Number it is not possible to set 21 as another Leading Number because of the possible overlap of extension numbers The number you are trying to store cannot be used if it is already being used by A feature number Another extension block A Dial setting see 11 1 9 1 TIE Table Quick Dialing see 4 10 2 6 2 Numbering Plan Qui...

Page 66: ...n A Dial setting see 11 1 9 1 TIE Table Quick Dialing see 4 10 2 6 2 Numbering Plan Quick Dial In any of these cases choose another number Q I cannot change a feature number on the B NA DND Call Feature screen A The number you are trying to store is already being used by another call feature Please choose a different number Q How do I prevent extension numbers being automatically assigned to a new...

Page 67: ...data is stored in the PBX s battery backup memory Incoming Call Log Outgoing Call Log including Last Number Redial Message Waiting SMDR ICD Group monitor log for supervisor PBX date and time Timed Reminder LPR Timed Update time PT handset headset volume PT SP PHONE volume PT ring volume PT display contrast ICD Group login status All extensions are set to Login by default ICD Group Ready Not Ready ...

Page 68: ...operty Extension Port screen is the same as that entered for another DSS Console Change this so that the numbers do not overlap Q I have set the type of an extension port to VM DPT but I cannot apply this setting Error E000403 A The DPT Type VM Unit No and DPT Type VM Port No settings entered on the 3 24 1 1 Slot Port Property Extension Port screen are the same as those entered for another VM DPT ...

Page 69: ...ICD group to receive CO line calls directly A Perform the following steps 1 On the 5 12 3 5 1 Incoming Call Distribution Group Group Settings screen enter the floating extension number you chose for the ICD group in the Floating Extension Number cell 2 Click Apply 3 On the 5 13 3 5 1 Incoming Call Distribution Group Group Settings Member List screen select the ICD group you created from the Incomi...

Page 70: ...ers from PC Console A Set the COS of the extension to which PC Console is connected to Manager class by setting Manager on the Extension Feature tab of the 4 12 2 7 1 Class of Service COS Settings screen to Enable System speed dialing numbers can only be edited by one PC Console at a time Q I have set FWD through system programming but calls are still not being forwarded A Perform the following st...

Page 71: ...Section 3 1 Configuration Document Version 2009 12 PC Programming Manual 71 ...

Page 72: ... the screen you wish to select Select Shelf will be shown under the mouse pointer 2 Click Select Shelf To access card properties 1 Move the mouse pointer over a card A menu will be shown under the mouse pointer 2 Select Card Property The property screen for that card will be displayed To access port properties 1 Move the mouse pointer over a card A menu will be shown under the mouse pointer 2 Sele...

Page 73: ...00 3 KX NCP1000 4 3 27 1 1 Slot Card Property LCO type PRI23 PRI Card 23B channels KX NCP500 2 KX NCP1000 2 3 30 1 1 Slot Card Property PRI type T1 T 1 CO Line Card 3 33 1 1 Slot Card Property T1 type OPB3 Optional 3 Slot Base Card KX NCP500 2 KX NCP1000 3 3 36 1 1 Slot OPB3 Card Property V IPEXT32 Virtual 32 Channel VoIP Extension Card KX NCP500 4 KX NCP1000 4 3 14 1 1 Slot Card Property Virtual ...

Page 74: ... 3 4 1 Virtual Cards 74 PC Programming Manual Document Version 2009 12 3 1 1 1 Slot ...

Page 75: ... Note that for IPCMPR cards the PBX model code is displayed in parentheses after the name Default Slot 00 IPCMPR IP Convergence Main Processing Card fixed Other slots Not stored Value Range DHLC4 4 Port Digital Hybrid Extension Card DLC8 8 Port Digital Extension Card DLC16 16 Port Digital Extension Card SLC8 8 Port Single Line Telephone Extension Card SLC16 16 Port Single Line Telephone Extension ...

Page 76: ...lot 00 fixed Other slots Current status Value Range INS The port is in service OUS The port is out of service Fault The port is not communicating with the network Pre Install A card has been added to the slot Idle No card is installed in the slot Maintenance Console Location 3 2 1 1 Slot Summary Programming Manual References 3 1 1 1 Slot Feature Manual References None Version Indicates the LPR ver...

Page 77: ...Default Not applicable Value Range 1 8 Maintenance Console Location 3 2 1 1 Slot Summary Programming Manual References 3 1 1 1 Slot Feature Manual References None Slot Type Indicates the slot type reference only Default 1 4 Trunk 5 8 Extension Value Range Trunk Extension Maintenance Console Location 3 2 1 1 Slot Summary Document Version 2009 12 PC Programming Manual 77 3 2 1 1 Slot Summary ...

Page 78: ...rd Maintenance Console Location 3 2 1 1 Slot Summary Programming Manual References 3 14 1 1 Slot Card Property Virtual IP Extension 3 17 1 1 Slot Card Property Virtual SIP Extension 3 9 1 1 Slot Shelf Property Virtual IP Gateway 3 20 1 1 Slot Card Property Virtual IPCS Feature Manual References None Status Indicates the card status reference only Default Current status Value Range INS The port is ...

Page 79: ...Maintenance Console Location 3 2 1 1 Slot Summary Programming Manual References 3 1 1 1 Slot Feature Manual References None Document Version 2009 12 PC Programming Manual 79 3 2 1 1 Slot Summary ...

Page 80: ...ey At default only IP softphones can be used IPCMPR ID Indicates the ID number of the IPCMPR card reference only Default Not applicable Value Range ID number of the IPCMPR card Maintenance Console Location 3 3 1 1 Slot Activation Key Programming Manual References None Feature Manual References None Activated Feature Indicates the type of activation keys reference only Note that the types of activa...

Page 81: ...r DSP64 card IP Trunk ch 16 IP Proprietary Telephone ch 32 Maintenance Console Location 3 3 1 1 Slot Activation Key Programming Manual References None Feature Manual References None The number of activated feature by Activation Key File in SD Card Indicates the number of channels or CA users provided by activation key files on the SD memory card reference only Default Not applicable Value Range No...

Page 82: ...r CA users provided by the DSP card and activation key files on the SD memory card reference only Default Not applicable Value Range Not applicable Maintenance Console Location 3 3 1 1 Slot Activation Key Programming Manual References None Feature Manual References None 82 PC Programming Manual Document Version 2009 12 3 3 1 1 Slot Activation Key ...

Page 83: ...ty IPCMPR Programming Manual References None Feature Manual References 4 1 2 DHCP Dynamic Host Configuration Protocol Assignment MAC Address for IPCMPR Card Indicates the MAC address of the IPCMPR card reference only Default Default MAC address Value Range 00 00 00 00 00 00 FF FF FF FF FF FF Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature M...

Page 84: ...dress for VoIP DSP Indicates the MAC address of either the DSP card reference only Default Default MAC address Value Range 00 00 00 00 00 00 FF FF FF FF FF FF Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None IP Address for VoIP DSP Specifies the IP address of either the DSP card This parameter is only available for ent...

Page 85: ...ult 255 255 255 0 Value Range 0 255 0 255 0 255 0 255 except 0 0 0 0 and 255 255 255 255 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Default Gateway Specifies the IP address of the default gateway for the network This parameter is only available for entering values when DHCP Client is disabled Default Not stored V...

Page 86: ...s half duplex 10Mbps full duplex 10Mbps half duplex Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Speed Duplex for Maintenance Port Specifies the connection mode of the maintenance port The connection is made in 100Mbps half duplex when Auto Negotiation fails Default Auto Negotiation Value Range Auto Negotiation 100...

Page 87: ...n via the LAN is detected Default 5 s Value Range 1 10 s Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None DHCP Port Number Specifies the port number used by a DHCP server Default 67 Value Range 1 65535 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Document Version 200...

Page 88: ...nces None Feature Manual References 4 1 2 DHCP Dynamic Host Configuration Protocol Assignment VoIP DSP Option DSP Card Type Indicates the type of the installed DSP card reference only Default None Value Range None DSP4 DSP16 DSP64 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None DSP Card Status Indicates whether the DS...

Page 89: ...enabled or disabled Default Enable Value Range Disable Enable Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References 16 1 8 SVM Simplified Voice Message IP Extension Count of BGM Specifies how many IP PTs connected to the IPCMPR card can send out BGM Default 4 Value Range When using the built in ESVM card 0 49 Document Version 20...

Page 90: ...erence only Default Current version number Value Range Version number Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Jitter Compensation Operation for G 711 Enables the use of a jitter buffer feature for voice communications using the G 711 codec Default Enable Value Range Disable Enable Maintenance Console Location ...

Page 91: ... 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Jitter Compensation Operation for G 729A Enables the use of a jitter buffer feature for communications using the G 729A codec Default Enable Value Range Disable Enable Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Document...

Page 92: ... Delay Max for Voice Specifies the maximum size of the jitter buffer for voice communications Default 200 ms Value Range 0 200 ms Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Jitter Buffer Delay Init for Voice Specifies the initial size of the jitter buffer for voice communications Default 20 ms Value Range 0 200 m...

Page 93: ... Value Range 1000 65530 ms Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Jitter Buffer Delay Min for FAX Specifies the minimum size of the jitter buffer for fax communications Default 20 ms Value Range 0 200 ms Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Document...

Page 94: ...rences None Jitter Buffer Delay Init for FAX Specifies the initial size of the jitter buffer for fax communications Default 50 ms Value Range 0 200 ms Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Jitter Buffer Adaptation Period for FAX Specifies the length of time that the jitter buffer is applied for fax communica...

Page 95: ... level of DTMF detection for the G 711A codec Default 23 dB Value Range 45 12 dB Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None DTMF Detection Level for G 711µ Specifies the level of DTMF detection for the G 711µ codec Default 29 dB Value Range 39 6 dB Document Version 2009 12 PC Programming Manual 95 3 4 1 1 Slot Ca...

Page 96: ...aintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None CNG Signal Effective Detection Width 2 OFF Specifies the length of time that the PBX waits until another CNG signal is detected Default 3000 ms Value Range 20 5000 ms Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None 96 PC P...

Page 97: ...ming Manual References None Feature Manual References None CED Signal Fixation Detection Time Specifies the minimum length of time required for the CED called station identification signal to be detected by the PBX Default 100 ms Value Range 50 n n 1 100 ms Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Document Vers...

Page 98: ...FAX Transmit Level Network to PBX µ Law Specifies the transmission level of G3 fax signals after being converted from T 38 protocol packets when the codec used is G 711µ Default 2 dB Value Range 7 8 dB Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None DSP CODEC G 711 only SIP extension Specifies whether or not to only u...

Page 99: ...Disable Value Range Enable Disable Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Feature Manual References None DSP CODEC Priority 1 value only others Specifies whether or not to only use the priority 1 codec set for the following types of calls IP extension calls SIP CO line calls Default Di...

Page 100: ...via the LAN Default 35300 Value Range 1 65535 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None LOGIN Port Number Specifies the port number used to login to the PBX via the LAN Default 33321 Value Range 1 65535 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None 100 PC Progr...

Page 101: ...t in Communication Assistant Server Specifies the port number for the Communication Assistant CA application Default 33334 Value Range 1024 65535 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 9 Built in Communication Assistant 6 10 4 2 1 Portable Station Extension Settings Option 9 Built in Communica...

Page 102: ...ences None LINK for Maintenance Port Indicates the current connection status of the maintenance port reference only Default Not applicable Value Range Disconnect Connect Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None DHCP DHCP Client Indicates the DHCP client function status of the IPCMPR card reference only 102 PC P...

Page 103: ...he IP address of the IPCMPR card reference only Default 192 168 0 101 Value Range 1 0 0 0 223 255 255 255 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None IP Address for VoIP DSP Indicates the IP address of either the DSP card reference only Default 192 168 0 102 Value Range 1 0 0 0 223 255 255 255 Document Version 200...

Page 104: ... 0 and 255 255 255 255 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None Feature Manual References None Default Gateway Indicates the IP address of the default gateway for the network reference only Default 0 0 0 0 Value Range 0 0 0 0 223 255 255 255 Maintenance Console Location 3 4 1 1 Slot Card Property IPCMPR Programming Manual References None 104...

Page 105: ...Feature Manual References None Document Version 2009 12 PC Programming Manual 105 3 4 1 1 Slot Card Property IPCMPR ...

Page 106: ...e To reach this screen move the mouse pointer over the IPCMPR card and click SVM Property Slot Indicates the slot type reference only Default IPCMPR Value Range IPCMPR Maintenance Console Location 3 5 1 1 Slot OPB3 Card Property Programming Manual References None Feature Manual References None Sub Slot Indicates the sub slot number reference only Default Current sub slot number Value Range Sub slo...

Page 107: ...ces None Status Indicates the status of the feature type of each slot reference only The sub slot 3 column offers two ways to open the screen to select the card command Click the desired cell in the column Select the desired cell in the column and then click Command Default Current status Value Range For sub slot 1 2 Not applicable For sub slot 3 INS Built in ESVM card is activated OUS Built in ES...

Page 108: ...B3 Card Property Programming Manual References None Feature Manual References None Port Status Indicates the port status of the built in ESVM card reference only Default Current port status Value Range For sub slot 1 2 Not applicable For sub slot 3 INS The card is activated OUS The card is not activated Maintenance Console Location 3 5 1 1 Slot OPB3 Card Property Programming Manual References None...

Page 109: ...erences 12 1 2 OGM Outgoing Message 16 1 8 SVM Simplified Voice Message MSG Feature Specifies whether or not to use the ESVM card as an MSG card OGM feature It is possible to use the ESVM card for the SVM feature as an MSG card OGM feature or both Default Enable Value Range Disable Enable Maintenance Console Location 3 5 1 1 Slot OPB3 Card Property Programming Manual References 3 36 1 1 Slot OPB3 ...

Page 110: ...t OPB3 Card Property Card Command Programming Manual References None Feature Manual References None OUS Takes the feature out of service Default Not applicable Value Range Not applicable Maintenance Console Location 3 6 1 1 Slot OPB3 Card Property Card Command Programming Manual References None Feature Manual References None 110 PC Programming Manual Document Version 2009 12 3 6 1 1 Slot OPB3 Card...

Page 111: ... 7 1 1 Slot Port Property Virtual IP Gateway Port Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 3 7 1 1 Slot Port Property Virtual IP Gateway Port Programming Manual References None Feature Manual References None Connection Indicates the port status ref...

Page 112: ...Port Property Virtual IP Gateway Port Programming Manual References None Feature Manual References None Call Distribution Port Group Specifies a call distribution port group to which incoming CO line calls are directed through the virtual VoIP gateway port Default 1 Value Range 1 16 Maintenance Console Location 3 7 1 1 Slot Port Property Virtual IP Gateway Port Programming Manual References None F...

Page 113: ...ming Manual References 3 15 1 1 Slot Port Property Virtual IP Extension Feature Manual References None OUS Takes the port out of service Value Range Not applicable Maintenance Console Location 3 8 1 1 Slot Port Property Virtual IP Gateway Port Connection Command Programming Manual References 3 15 1 1 Slot Port Property Virtual IP Extension Feature Manual References None Document Version 2009 12 PC...

Page 114: ...le Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None Call Signalling Model Specifies whether to carry out a call control H 225 process directly between the cards or through a gatekeeper Default Direct Value Range Direct GateKeeper Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual Re...

Page 115: ...None Primary Gatekeeper IP Address Specifies the IP address of the primary gatekeeper Default 192 168 1 3 Value Range 1 0 0 0 223 255 255 255 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None Primary Gatekeeper Port Number Specifies the port number of the primary gatekeeper Default 1719 Value Range 1 65535 ...

Page 116: ...55 255 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None Secondary Gatekeeper Port Number Specifies the port number of the secondary gatekeeper Default 1719 Value Range 1 65535 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None 116 PC Programming M...

Page 117: ...ber Specifies the port number for the H 225 protocol RAS in an H 323 protocol suite Default 1719 Value Range 1 65535 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None QSIG Connectionless Tunneling TCP Port Number Specifies the TCP port number for connectionless tunneling between gateway devices at different...

Page 118: ...een gateway devices at different locations in a QSIG network Default 1717 Value Range 1 65535 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None H 323 Dynamic Port Number Specifies the starting port number from which 448 contiguous ports are used as dynamic ports Default 10000 Value Range 1 65000 118 PC Prog...

Page 119: ...sole Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None RTCP Packet Interval Specifies the length of time until the PBX retries to send RTCP packets when no reply is received Default 5 s Value Range 5 60 s Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Document Ver...

Page 120: ...g Manual References None Feature Manual References None RTP QoS ToS Priority Specifies the priority level in the ToS field Default 0 Value Range 0 7 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None RTP QoS ToS Type Specifies the ToS type in the ToS field 120 PC Programming Manual Document Version 2009 12 3...

Page 121: ...CP Specifies the value in the ToS field by a DSCP for DiffServ Default 0 Value Range 0 63 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None RTP QoS HEX Specifies the value in the ToS field by a hexadecimal number Default 00 Value Range 00 FF Document Version 2009 12 PC Programming Manual 121 3 9 1 1 Slot Sh...

Page 122: ...ocation 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone DSP Digital Gain Down Specifies the DSP Digital Gain for the down voice path Default 0 dB Value Range 14 6 dB Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None 122 PC Programming Manual...

Page 123: ...anual References 9 1 15 IP PT IP Proprietary Telephone EC Gain Specifies the Echo Canceller Gain Default 0 dB Value Range 14 6 dB Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone NLP Setting Specifies the NLP Non Linear Processor setting to control echo sound quality Docume...

Page 124: ...QSIG network Default Yes Value Range No Yes Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References 13 1 24 Private Network Features QSIG CT Call Transfer QSIG CF Enables a call to be forwarded to a destination extension at another PBX in a QSIG network When using the Centralized VM feature set this to No Default Yes ...

Page 125: ... References None Feature Manual References None Outgoing Call En bloc Dialing setting Selects the call dialing mode Default Overlap Value Range En bloc The PBX sends all of the dialed digits at once after the extension user completes dialing The PBX recognizes the end of dialing when 1 is dialed if programmed 2 a preprogrammed telephone number is dialed or 3 the inter digit timer expires Overlap T...

Page 126: ...ce Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None Overlap Inter digit Timer T302 2 Specifies the length of time within which subsequent digits of a dial number must be dialed Default 5 s Value Range 1 10 s Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None ...

Page 127: ...codec This feature conserves bandwidth by detecting silent periods during a call and suppressing the packets of silence from being sent to the network Default Disable Value Range Disable Enable Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None Voice Codec Priority 1st Specifies the highest priority codec ty...

Page 128: ...ghest priority codec type Default None Value Range None G 711A G 711µ G 729A Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None Voice Codec Priority 3rd Specifies the third highest priority codec type Default None Value Range None G 711A G 711µ G 729A 128 PC Programming Manual Document Version 2009 12 3 9 1 ...

Page 129: ...ntenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None Packet Sampling Time for G 711µ Specifies the time interval between measurements samples of sound data during a conversation The smaller this number the higher the quality of the transmitted sound Default 20 ms Value Range 10 ms 20 ms 30 ms 40 ms 50 ms 60 ms Ma...

Page 130: ...tection Ability Enables the use of the FAX Detection Ability feature Since fax signals using a codec other than G 711 cannot be received accurately at the destination this feature automatically switches the codec to G 711 to enable end to end fax signal relay over the network Default Enable Value Range Disable Enable Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Progr...

Page 131: ...e payload type for DTMF tones using RFC2833 Programming this parameter is only necessary if DTMF is set to Outband RFC2833 Default 101 Value Range 96 127 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None T38 FAX Max Datagram Specifies the maximum datagram size when using the T 38 protocol Default 512 Docume...

Page 132: ...le Value Range Disable Enable Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None T38 FAX UDPTL Redundancy count for T 30 messages Specifies the redundancy count for T 30 messages when using the T 38 protocol Default 3 Value Range 0 7 Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway...

Page 133: ...ateway Programming Manual References None Feature Manual References None T38 FAX Rate Management Method Specifies the rate management method when using the T 38 protocol Default Transferred TCF Value Range Transferred TCF Local TCF Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None Document Version 2009 12 P...

Page 134: ...maximum time allowed between each digit on an incoming call Applies to overlap receiving Default 150 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None T303 Specifies the maximum time that the PBX waits for a reply after sending the SETUP call setting message Default 60 100 ms...

Page 135: ...Value Range 0 3000 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None T305 Specifies the maximum time that the PBX waits for a reply after sending the DISC disconnection message Default 150 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Doc...

Page 136: ... Gateway Programming Manual References None Feature Manual References None T309 Specifies the length of time after which the PBX tries to disconnect the data link before disconnecting the call Default 120 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None 136 PC Programming M...

Page 137: ...erences None T313 Specifies the maximum time that the PBX waits for a reply after sending the Connect message Default 60 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None T316 Specifies the maximum time that the PBX waits for a reply after sending the Restart message Default ...

Page 138: ...s Value Range 0 600 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None T319 Specifies the maximum time that the PBX waits for a reply after sending the Suspend message Default 0 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway 138 PC Programmi...

Page 139: ...erty Virtual IP Gateway Programming Manual References None Feature Manual References None T3D3 Specifies the length of time after which the PBX tries to establish L2 in Permanent mode Default 50 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None Document Version 2009 12 PC Pr...

Page 140: ...ll mode Default 200 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 9 1 1 Slot Shelf Property Virtual IP Gateway Programming Manual References None Feature Manual References None 140 PC Programming Manual Document Version 2009 12 3 9 1 1 Slot Shelf Property Virtual IP Gateway ...

Page 141: ... Shelf Property Virtual IP Gateway GK Settings Programming Manual References None Feature Manual References None Device Name Specifies the name of the device for programming reference Default Not stored Value Range Max 20 characters Maintenance Console Location 3 10 1 1 Slot Shelf Property Virtual IP Gateway GK Settings Programming Manual References None Feature Manual References None Document Ver...

Page 142: ...racters Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Manual References None GW IP Address Specifies the IP address of the destination gateway device Default Not stored Value Range 1 0 0 0 223 255 255 255 Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual R...

Page 143: ...use of the Voice Activity Detection feature between the V IPGW and KX TDE KX TDA IP GW16 cards Default Enable TDA Value Range Disable TDE Enable TDA Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Manual References None Protocol Specifies the type of protocol for connectionless tunneling between gateway devices at ...

Page 144: ...ress tones are audible at the destination Default Internal Value Range External Internal Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Manual References None Option 1 GW Name Specifies the name of the destination gateway device for programming reference Default Not stored Value Range Max 20 characters 144 PC Prog...

Page 145: ...1A G 711Mu G 729A For 2nd and 3rd None G 711A G 711Mu G 729A Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Manual References None Packet Sampling Time G 711A Specifies the time interval between measurements samples of sound data during a conversation The smaller this number the higher the quality of the transmitt...

Page 146: ...ole Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Manual References None Packet Sampling Time G 729A Specifies the time interval between measurements samples of sound data during a conversation The smaller this number the higher the quality of the transmitted sound Default 20 ms Value Range 10 ms 20 ms 30 ms 40 ms 50 ms 60 ms Mainte...

Page 147: ...etection for G 711 Enables the use of the Voice Activity Detection feature for the G 711 codec This feature conserves bandwidth by detecting silent periods during a call and suppressing the packets of silence from being sent to the network Default Disable Value Range Disable Enable Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual Reference...

Page 148: ...Slot Shelf Property Virtual IP Gateway GW Settings Option 1 IP Codec Priority 1st 2nd 3rd Feature Manual References None DTMF Specifies the method to transport DTMF tones Default Outband H 245 Value Range Inband Outband RFC2833 Outband H 245 Maintenance Console Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Manual References None Pay...

Page 149: ...ole Location 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings Programming Manual References None Feature Manual References None Document Version 2009 12 PC Programming Manual 149 3 11 1 1 Slot Shelf Property Virtual IP Gateway GW Settings ...

Page 150: ...enance Console Location 3 12 1 1 Slot Shelf Property Virtual IP Gateway DN2IP Programming Manual References None Feature Manual References None Remaining Number of Digits Specifies the number of digits to be dialed following the leading number to access the destination Default 0 Value Range 0 29 Maintenance Console Location 3 12 1 1 Slot Shelf Property Virtual IP Gateway DN2IP Programming Manual R...

Page 151: ...None Feature Manual References None GW Group Specifies the number of the destination gateway group Default 1 Value Range 1 256 Maintenance Console Location 3 12 1 1 Slot Shelf Property Virtual IP Gateway DN2IP Programming Manual References None Feature Manual References None GW No Specifies the number of the destination gateway device Default 1 Value Range 1 512 Document Version 2009 12 PC Program...

Page 152: ...on 3 12 1 1 Slot Shelf Property Virtual IP Gateway DN2IP Programming Manual References None Feature Manual References None 152 PC Programming Manual Document Version 2009 12 3 12 1 1 Slot Shelf Property Virtual IP Gateway DN2IP ...

Page 153: ...Value Range Max 30 digits consisting of 0 9 Maintenance Console Location 3 13 1 1 Slot Shelf Property Virtual IP Gateway Hunt Pattern Programming Manual References None Feature Manual References None Call Distribution Port Group 1st 16th Specifies the number of the call distribution port group to which incoming calls are directed in priority Default 1st CDPG1 2nd 16th None Value Range For 1st CDPG...

Page 154: ...ot Port Property Virtual IP Gateway Port Call Distribution Port Group Feature Manual References 3 1 2 Call Distribution Port Group 154 PC Programming Manual Document Version 2009 12 3 13 1 1 Slot Shelf Property Virtual IP Gateway Hunt Pattern ...

Page 155: ...xtension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone Signaling MGCP UDP Port No Server Specifies the UDP port used by the V IPEXT card to transmit and receive MGCP Media Gateway Control Protocol data This must be changed if another network application is using the same port To change the value displayed here click Common Settings and set the d...

Page 156: ...e RTP UDP Port No Server Specifies the UDP port used by the V IPEXT card to transmit and receive RTP Realtime Transfer Protocol data This must be changed if another network application is using the same port For voice communications the V IPEXT card uses 64 contiguous UDP ports starting from the port number specified here To change the value displayed here click Common Settings and set the desired...

Page 157: ...ontinue to consider an IP PT to be active even if it receives no transmissions from that IP PT The PBX constantly confirms the status of IP PTs If no communications are received from an IP PT for the duration specified here the PBX considers the IP PT to be unreachable and sets the port status to Fault During operation set between 10 s and 60 s Settings over 60 s and Disable are used for debugging...

Page 158: ...ng Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone Resending Time Out PTAP Specifies the length of time after which the PBX terminates resending PTAP Panasonic Telephony Administration Protocol data To change the value displayed here click Common Settings and set the desired value Default 150 s Value Range 150 240 s Maintenance Console Location 3 14 1 1 Slot ...

Page 159: ... IP Proprietary Telephone Resending Time Out MGCP Specifies the length of time after which the PBX terminates resending MGCP Media Gateway Control Protocol data To change the value displayed here click Common Settings and set the desired value Default 75 s Value Range 75 120 s Maintenance Console Location 3 14 1 1 Slot Card Property Virtual IP Extension Programming Manual References None Feature M...

Page 160: ... DSP Digital Gain for the down voice path Default 6 dB Value Range 14 6 dB Maintenance Console Location 3 14 1 1 Slot Card Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone DSP Digital Gain Up Specifies the DSP Digital Gain for the up voice path Default 0 dB Value Range 14 6 dB 160 PC Programming Manual Document Version...

Page 161: ...Slot Card Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone NLP Setting Specifies the NLP Non Linear Processor setting to control echo sound quality Default Weak Value Range Disable Weak Normal Strong Maintenance Console Location 3 14 1 1 Slot Card Property Virtual IP Extension Programming Manual References None Documen...

Page 162: ...Feature Manual References 9 1 15 IP PT IP Proprietary Telephone 162 PC Programming Manual Document Version 2009 12 3 14 1 1 Slot Card Property Virtual IP Extension ...

Page 163: ...f the registration is successful the dialog box will show Registration Completed Click Close Once the IP PT is successfully registered the status of the IP PT will update to show Registered De registration Follow the steps below to de register the IP PT 1 Click De registration A dialog box will appear Registered extension numbers and names are displayed on the left 2 Highlight numbers and names an...

Page 164: ...ber Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature ...

Page 165: ...lt Not stored Value Range Max 20 characters Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone Connection Indicates the port status reference only This column offers two ways to open the screen to select the port command Click the desired cell in the column Select the desir...

Page 166: ...rence only Default None Value Range None Registered Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone IP Phone Registration ID MAC Address Specifies the MAC address of the IP PT This parameter can only be modified when Connection on this screen is set to OUS Default Defaul...

Page 167: ...enance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone Program Ver Indicates the program software file version of the IP PT reference only Default Current version number Value Range Version number Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programm...

Page 168: ...e Manual References 9 1 15 IP PT IP Proprietary Telephone Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone Extension Number Specifies the extension number of the port 168 PC ...

Page 169: ...nance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone Connection Indicates the port status reference only This column offers two ways to open the screen to select the port command Click the desired cell in the column Select the desired cell in the column and then click Command Defau...

Page 170: ...et OFF Value Range Headset OFF Headset ON Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone Ringing Tone Selects the dual tone switching pattern of the ring tone for incoming calls Default A Value Range A 64 ms 697 Hz 64 ms 852 Hz B 32 ms 697 Hz 32 ms 852 Hz C 128 ms 697 H...

Page 171: ...is selected both G 711 and G 722 are unavailable Default G 722 Value Range G 711 G 729A G 722 Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone Packet Sampling Time G 711 G 722 Specifies the time interval between measurements samples of sound data during a conversation The...

Page 172: ...onversation The smaller this number the higher the quality of the transmitted sound Default 20 ms Value Range 20 ms 30 ms 40 ms 60 ms Maintenance Console Location 3 15 1 1 Slot Port Property Virtual IP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone 172 PC Programming Manual Document Version 2009 12 3 15 1 1 Slot Port Property Virtual IP...

Page 173: ...mming Manual References 3 15 1 1 Slot Port Property Virtual IP Extension Feature Manual References None OUS Takes the port out of service Default Not applicable Value Range Not applicable Maintenance Console Location 3 16 1 1 Slot Port Property Virtual IP Extension Connection Command Programming Manual References 3 15 1 1 Slot Port Property Virtual IP Extension Feature Manual References None Docum...

Page 174: ...nual References None Feature Manual References 9 1 4 ICD Group Features Outside Destinations SIP Location Hold Time Max Specifies the maximum length of time that the PBX holds information on the location of SIP Extensions To change the value displayed here click Common Settings and set the desired value Default 320 s Value Range 10 3600 s Maintenance Console Location 3 17 1 1 Slot Card Property Vi...

Page 175: ...PBX waits before starting to hold information on location of SIP Extensions To change the value displayed here click Common Settings and set the desired value Default 1 s Value Range 1 10 s Maintenance Console Location 3 17 1 1 Slot Card Property Virtual SIP Extension Programming Manual References None Feature Manual References 9 1 4 ICD Group Features Outside Destinations SIP Session Timer Min Sp...

Page 176: ...echo canceller ability time Default 48 ms Value Range OFF 48 ms 128 ms Maintenance Console Location 3 17 1 1 Slot Card Property Virtual SIP Extension Programming Manual References None Feature Manual References 9 1 15 IP PT IP Proprietary Telephone DSP Digital Gain Down Specifies the DSP Digital Gain for the down voice path Default 0 dB Value Range 14 6 dB 176 PC Programming Manual Document Versio...

Page 177: ... 14 6 dB Maintenance Console Location 3 17 1 1 Slot Card Property Virtual SIP Extension Programming Manual References None Feature Manual References 16 1 2 SIP Session Initiation Protocol Extension EC Gain Specifies the Echo Canceller Gain Default 0 dB Value Range 14 6 dB Maintenance Console Location 3 17 1 1 Slot Card Property Virtual SIP Extension Programming Manual References None Document Vers...

Page 178: ...und quality Default Weak Value Range Disable Weak Normal Strong Maintenance Console Location 3 17 1 1 Slot Card Property Virtual SIP Extension Programming Manual References None Feature Manual References 16 1 2 SIP Session Initiation Protocol Extension 178 PC Programming Manual Document Version 2009 12 3 17 1 1 Slot Card Property Virtual SIP Extension ...

Page 179: ...roperty Virtual SIP Extension Port Programming Manual References None Feature Manual References 16 1 2 SIP Session Initiation Protocol Extension Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 3 18 1 1 Slot Port Property Virtual SIP Extension Port Programming Manual References None Feature Manual References 16 1 2 SIP S...

Page 180: ...sword clicking Copy to button This parameter can only be modified when the virtual SIP extension port is set to OUS Default Not stored Value Range 3 16 characters consisting of 0 9 a z A Z Maintenance Console Location 3 18 1 1 Slot Port Property Virtual SIP Extension Port Programming Manual References None Feature Manual References 16 1 2 SIP Session Initiation Protocol Extension Connection Indica...

Page 181: ...current IP address of the SIP Extension reference only Default Current IP address Value Range 1 0 0 0 223 255 255 255 Maintenance Console Location 3 18 1 1 Slot Port Property Virtual SIP Extension Port Programming Manual References None Feature Manual References 16 1 2 SIP Session Initiation Protocol Extension Bearer Selects the bearer mode When Automatic is selected the bearer mode is set to Spee...

Page 182: ...ce Console Location 3 18 1 1 Slot Port Property Virtual SIP Extension Port Programming Manual References None Feature Manual References 16 1 2 SIP Session Initiation Protocol Extension Packet Sampling Time G 729A Specifies the time interval between measurements samples of sound data during a conversation The smaller this number the higher the quality of the transmitted sound Default 20 ms Value Ra...

Page 183: ...nces None Feature Manual References 16 1 2 SIP Session Initiation Protocol Extension Voice Activity Detection for G 729A Enables the use of the Voice Activity Detection feature for the G 729A codec This feature conserves bandwidth by detecting silent periods during a call and suppressing the packets of silence from being sent to the network Default OFF Value Range OFF ON Maintenance Console Locati...

Page 184: ...ty Virtual SIP Extension Port Feature Manual References 16 1 2 SIP Session Initiation Protocol Extension OUS Takes the port out of service Default Not applicable Value Range Not applicable Maintenance Console Location 3 19 1 1 Slot Port Property Virtual SIP Extension Port Connection Command Programming Manual References 3 18 1 1 Slot Port Property Virtual SIP Extension Port Feature Manual Referenc...

Page 185: ... 3 20 1 1 Slot Card Property Virtual IPCS Programming Manual References None Feature Manual References None Signaling MGCP UDP Port No Server Specifies the UDP port used by the V IPCS card to transmit and receive MGCP Media Gateway Control Protocol data This must be changed if another network application is using the same port To change the value displayed here click Common Settings and set the de...

Page 186: ... Voice RTP UDP Port No Server Specifies the UDP port used by the V IPCS card to transmit and receive RTP Realtime Transfer Protocol data This must be changed if another network application is using the same port For voice communications the V IPCS card uses 64 contiguous UDP ports starting from the port number specified here To change the value displayed here click Common Settings and set the desi...

Page 187: ...nsider an IP CS to be active even if it receives no transmissions from that IP CS The PBX constantly confirms the status of IP CSs If no communications are received from an IP CS for the duration specified here the PBX considers the IP CS to be unreachable and sets the port status to Fault During operation set between 10 s and 60 s Settings over 60 s and Disable are used for debugging purposes and...

Page 188: ...rtual IPCS Programming Manual References None Feature Manual References None Resending Time Out PTAP Specifies the length of time after which the PBX terminates resending PTAP Panasonic Telephony Administration Protocol data To change the value displayed here click Common Settings and set the desired value Default 150 s Value Range 150 240 s Maintenance Console Location 3 20 1 1 Slot Card Property...

Page 189: ...eature Manual References None Resending Time Out MGCP Specifies the length of time after which the PBX terminates resending MGCP Media Gateway Control Protocol data To change the value displayed here click Common Settings and set the desired value Default 75 s Value Range 75 120 s Maintenance Console Location 3 20 1 1 Slot Card Property Virtual IPCS Programming Manual References None Feature Manua...

Page 190: ... the DSP Digital Gain for the down voice path Default 0 dB Value Range 14 6 dB Maintenance Console Location 3 20 1 1 Slot Card Property Virtual IPCS Programming Manual References None Feature Manual References None DSP Digital Gain Up Specifies the DSP Digital Gain for the up voice path Default 9 dB Value Range 14 6 dB 190 PC Programming Manual Document Version 2009 12 3 20 1 1 Slot Card Property ...

Page 191: ... 20 1 1 Slot Card Property Virtual IPCS Programming Manual References None Feature Manual References None NLP Setting Specifies the NLP Non Linear Processor setting to control echo sound quality Default Weak Value Range Disable Weak Normal Strong Maintenance Console Location 3 20 1 1 Slot Card Property Virtual IPCS Programming Manual References None Document Version 2009 12 PC Programming Manual 1...

Page 192: ...Feature Manual References None 192 PC Programming Manual Document Version 2009 12 3 20 1 1 Slot Card Property Virtual IPCS ...

Page 193: ... Completed Click Close Once the IP CS is successfully registered the status of the IP CS will update to show Registered De registration Follow the steps below to de register the IP CS 1 Click De registration A dialog box will appear Registered IP CSs are displayed on the left 2 Highlight IP CSs and click the right arrow to select them for de registration Click Next A dialog box will appear 3 Click...

Page 194: ...ort Property Virtual IPCS Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 3 21 1 1 Slot Port Property Virtual IPCS Programming Manual References None Feature Manual References None CS Name Specifies the CS name of the port 194 PC Programming Manual Docume...

Page 195: ...l in the column Select the desired cell in the column and then click Command Default Current status Value Range INS The port is in service OUS The port is out of service Fault The port is not communicating with the network Maintenance Console Location 3 21 1 1 Slot Port Property Virtual IPCS Programming Manual References None Feature Manual References None Status Indicates whether a certain IP CS ...

Page 196: ... 00 00 00 00 00 FF FF FF FF FF FF Maintenance Console Location 3 21 1 1 Slot Port Property Virtual IPCS Programming Manual References None Feature Manual References None Current IP Address Indicates the current IP address of the IP CS reference only Default Current IP address Value Range 1 0 0 0 223 255 255 255 Maintenance Console Location 3 21 1 1 Slot Port Property Virtual IPCS 196 PC Programmin...

Page 197: ...rtual IPCS Programming Manual References None Feature Manual References None Air Sync Group No Assigns an Air Synchronization Group number to the IP CS Default 1 Value Range None 1 Maintenance Console Location 3 21 1 1 Slot Port Property Virtual IPCS Programming Manual References 5 26 3 10 Air Synchronization Group 13 6 11 5 Air Synchronization Feature Manual References None Document Version 2009 ...

Page 198: ...rogramming Manual References 5 26 3 10 Air Synchronization Group 13 6 11 5 Air Synchronization Feature Manual References None Option Slot Indicates the slot position reference only Default Current slot number Value Range Slot number Maintenance Console Location 3 21 1 1 Slot Port Property Virtual IPCS Programming Manual References None Feature Manual References None Port Indicates the port number ...

Page 199: ...ole Location 3 21 1 1 Slot Port Property Virtual IPCS Programming Manual References None Feature Manual References None Connection Indicates the port status reference only This column offers two ways to open the screen to select the port command Click the desired cell in the column Select the desired cell in the column and then click Command Default Current status Value Range INS The port is in se...

Page 200: ...9A Maintenance Console Location 3 21 1 1 Slot Port Property Virtual IPCS Programming Manual References None Feature Manual References None Packet Sampling Time G 711 Specifies the time interval between measurements samples of sound data during a conversation The smaller this number the higher the quality of the transmitted sound Default 20 ms Value Range 10 ms 20 ms 30 ms 40 ms 50 ms 60 ms Mainten...

Page 201: ...Programming Manual References None Feature Manual References None Voice Activity Detection for G 711 Enables the use of the Voice Activity Detection feature for the G 711 codec This feature conserves bandwidth by detecting silent periods during a call and suppressing the packets of silence from being sent to the network Default Disable Value Range Disable Enable Maintenance Console Location 3 21 1...

Page 202: ...rogramming Manual References 3 21 1 1 Slot Port Property Virtual IPCS Feature Manual References None OUS Takes the port out of service Default Not applicable Value Range Not applicable Maintenance Console Location 3 22 1 1 Slot Port Property Virtual IPCS Connection Command Programming Manual References 3 21 1 1 Slot Port Property Virtual IPCS Feature Manual References None 202 PC Programming Manua...

Page 203: ...y Extension Type Programming Manual References None Feature Manual References None SLT Off Hook Time Specifies the minimum length that a pulse dial sent from an SLT must be for the PBX to recognize it as an off hook signal Default 160 ms Value Range 8 n n 3 255 ms Maintenance Console Location 3 23 1 1 Slot Card Property Extension Type Programming Manual References None Feature Manual References No...

Page 204: ...ure Manual References None SLT Pulse Maximum Break Width Specifies the maximum length of the break signal in a pulse dial Default 96 ms Value Range 8 n n 9 20 ms Maintenance Console Location 3 23 1 1 Slot Card Property Extension Type Programming Manual References None Feature Manual References None SLT Pulse Minimum Make Width Specifies the minimum length of the make signal in a pulse dial Default...

Page 205: ...X disconnects the line to prevent placing the call on hold Enable The PBX places the call on consultation hold Maintenance Console Location 3 23 1 1 Slot Card Property Extension Type Programming Manual References None Feature Manual References 3 1 9 Call Splitting Flash Timing Min Specifies the minimum length that a signal sent from an SLT must be for the PBX to recognize it as a hookswitch flash ...

Page 206: ... n 3 191 ms Maintenance Console Location 3 23 1 1 Slot Card Property Extension Type Programming Manual References None Feature Manual References None DTMF R STD Detection Time Specifies the minimum length that a DTMF tone must be for the PBX to recognize it as a DTMF tone Default 30 ms Value Range 2 n n 1 31 ms Maintenance Console Location 3 23 1 1 Slot Card Property Extension Type Programming Man...

Page 207: ...the APT for calls Default Enable Value Range Disable Enable Maintenance Console Location 3 23 1 1 Slot Card Property Extension Type Programming Manual References None Feature Manual References 13 1 2 Paralleled Telephone Document Version 2009 12 PC Programming Manual 207 3 23 1 1 Slot Card Property Extension Type ...

Page 208: ...er Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Programming Manual References None Feature Manual References None Port Indicates the port or channel number reference only Default Current port or channel number Value Range Port or channel number Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Programming Manual References None Feature Manual Refere...

Page 209: ...xtension Port Configuration Telephone Type Indicates the connected telephone type reference only The number of all connected telephones and Cell Stations can be viewed by clicking Port Type View Default Current connected telephone type Value Range DPT 40V DPT is connected APT 15V APT is connected DSS DSS Console is connected VM VPS is connected SLT SLT is connected or no telephone is connected to ...

Page 210: ...e port is out of service Fault The port is not communicating with the PBX Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Number Specifies the extension number of the port Default Starting at 101 Value Range Max 5 digits consisting of 0 9 Main...

Page 211: ...creen is set to S Hybrid Default Off Value Range On XDP enabled The main telephone and sub telephone have different extension numbers This is called XDP Mode Off XDP disabled The main telephone and sub telephone both have the main telephone s extension number This is called Parallel Mode Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Programming Manual References None Feat...

Page 212: ... 1 1 Wired Extension Extension Settings screen the Wireless XDP setting must be deleted first When changing the type of a port for which one or more SDN buttons are set except when changing between PC Console and Telephone all SDN buttons customized for that device will be deleted When you attempt to apply the new settings a warning message is displayed showing the slot and port number for which S...

Page 213: ...ustomized for that device will be deleted When you attempt to apply the new settings a warning message is displayed showing the slot and port number for which SDN buttons will be deleted If you do not wish to delete SDN buttons for this port click Cancel Default 1 Value Range 1 8 Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Programming Manual References None Feature Manu...

Page 214: ...ramming Manual References None Feature Manual References 19 1 3 Voice Mail VM Group DPT Type Air Sync Group No Assigns an Air Synchronization Group number to the CS This setting is only available when DPT Type Type on this screen is set to Normal Default 1 Value Range None 1 Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Programming Manual References 5 26 3 10 Air Synchron...

Page 215: ...26 3 10 Air Synchronization Group 13 6 11 5 Air Synchronization Feature Manual References None Headset OFF ON Turns on or off the use of a headset with a DPT This setting is only available when Port Type on this screen is set to DPT DPT S DPT S Hybrid or S Hybrid S DPT Default Headset OFF Value Range Headset OFF Headset ON Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Pro...

Page 216: ...e for the KX T7200 the KX T7451 APTs or SLTs Default A Value Range A 64 ms 697 Hz 64 ms 852 Hz B 32 ms 697 Hz 32 ms 852 Hz C 128 ms 697 Hz 128 ms 852 Hz D 32 ms 697 Hz 96 ms 852 Hz Maintenance Console Location 3 24 1 1 Slot Port Property Extension Port Programming Manual References None Feature Manual References None 216 PC Programming Manual Document Version 2009 12 3 24 1 1 Slot Port Property Ex...

Page 217: ...t Property Extension Port Feature Manual References None OUS Takes the port out of service This enables a temporary non use of the port for example for the purpose of repair Default Not applicable Value Range Not applicable Maintenance Console Location 3 25 1 1 Slot Port Property Extension Port Connection Command Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Manu...

Page 218: ...y Extension Port Port Type View Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Manual References None Total Count Indicates the total number of each type of telephone and CS connected to the PBX reference only CSs are counted on the basis of the number of ports in service plus the number of extension ports to which CSs are connected Default Not applicable Value Ra...

Page 219: ...Feature Manual References None Document Version 2009 12 PC Programming Manual 219 3 26 1 1 Slot Port Property Extension Port Port Type View ...

Page 220: ...ences None Feature Manual References None First Dial Timer CO Specifies the minimum time that the PBX waits after seizing a CO line before sending the dialed digits to the telephone company This allows the telephone company to have enough time to accept the dialed digits correctly Default 1 0 s Value Range 0 5 n n 1 16 s Maintenance Console Location 3 27 1 1 Slot Card Property LCO type Programming...

Page 221: ...imum length of a bell signal that can be recognized by the PBX as the bell signal sent from the telephone company before the PBX detects an arriving call Default 144 ms Value Range 24 n n 1 50 ms Maintenance Console Location 3 27 1 1 Slot Card Property LCO type Programming Manual References None Feature Manual References None Bell Detection Bell Off Detection Timer Specifies the duration of the be...

Page 222: ...aled digits correctly Default 112 ms Value Range 64 16 n n 0 11 ms Maintenance Console Location 3 27 1 1 Slot Card Property LCO type Programming Manual References None Feature Manual References None Pulse DTMF Dial Pulse Inter digit Pause Specifies the length of the pulse inter digit pause This allows the telephone company to have enough time to accept the dialed digits correctly Default 830 ms Va...

Page 223: ...ard Property LCO type Programming Manual References 3 28 1 1 Slot Port Property LCO Port Feature Manual References None Low Speed Pulse Dial Break Width Specifies the maximum length of the break signal in a low speed pulse dial Low Speed Pulse Dial Pulse Break on this screen determines the value that can be specified here Default 60 ms Value Range 4 n n 6 20 ms Maintenance Console Location 3 27 1 ...

Page 224: ...ng Manual References 3 28 1 1 Slot Port Property LCO Port Feature Manual References None High Speed Pulse Dial Pulse Break Specifies the break for a high speed pulse dial This is the ratio between the break on hook signal and make off hook signal in a pulse dial Default 60 Value Range Other 60 67 Maintenance Console Location 3 27 1 1 Slot Card Property LCO type Programming Manual References 3 28 1...

Page 225: ...ences None High Speed Pulse Dial Make Width Specifies the minimum length of the make signal in a high speed pulse dial High Speed Pulse Dial Pulse Break on this screen determines the value that can be specified here Default 20 ms Value Range 4 n n 3 15 ms Maintenance Console Location 3 27 1 1 Slot Card Property LCO type Programming Manual References 3 28 1 1 Slot Port Property LCO Port Feature Man...

Page 226: ...ange None Caller ID Card Maintenance Console Location 3 27 1 1 Slot Card Property LCO type Programming Manual References 3 28 1 1 Slot Port Property LCO Port Caller ID Detection Feature Manual References 3 1 3 Caller ID Caller ID Caller ID Signaling Selects the type of Caller ID signaling provided by the telephone company Default FSK Value Range FSK FSK with Visual Caller ID DTMF Maintenance Conso...

Page 227: ...ces None Feature Manual References 3 1 3 Caller ID Caller ID Caller ID FSK Carrier Detection Enables the PBX to detect the carrier when receiving Caller ID To enable this setting Caller ID Caller ID Signaling on this screen should be set to FSK Default Enable Value Range Disable Enable Maintenance Console Location 3 27 1 1 Slot Card Property LCO type Programming Manual References None Feature Manu...

Page 228: ...e this setting Caller ID Caller ID Signaling on this screen should be set to FSK Default Enable Value Range Disable Enable Maintenance Console Location 3 27 1 1 Slot Card Property LCO type Programming Manual References None Feature Manual References 3 1 3 Caller ID Caller ID Caller ID FSK Detection Start Timer Specifies the length of time that the PBX waits before attempting to detect Caller ID in...

Page 229: ...e total time required by the PBX to detect Caller ID information To enable this setting Caller ID Caller ID Signaling on this screen should be set to FSK Default 2000 ms Value Range 80 n n 13 50 ms Maintenance Console Location 3 27 1 1 Slot Card Property LCO type Programming Manual References None Feature Manual References 3 1 3 Caller ID Document Version 2009 12 PC Programming Manual 229 3 27 1 1...

Page 230: ...n 3 28 1 1 Slot Port Property LCO Port Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 3 28 1 1 Slot Port Property LCO Port Programming Manual References None Feature Manual References None Connection Indicates the port status reference only 230 PC Progra...

Page 231: ...es None Dialing Mode Selects the type of signal used to dial out to the analog CO line Default DTMF Value Range DTMF Pulse Maintenance Console Location 3 28 1 1 Slot Port Property LCO Port Programming Manual References None Feature Manual References 4 1 3 Dial Mode Selection CPC Signal Detection Time Outgoing Incoming Specifies the length of time required by the PBX to detect a CPC signal on outgo...

Page 232: ...dth Selects the length of the DTMF tone sent to the analog CO line Default 80 ms Value Range 80 ms 160 ms Maintenance Console Location 3 28 1 1 Slot Port Property LCO Port Programming Manual References None Feature Manual References None Pulse Speed Selects the speed at which pulse dials are sent to the analog CO line Default Low Value Range Low High 232 PC Programming Manual Document Version 2009...

Page 233: ... only Both Call For both outgoing and incoming CO line calls Maintenance Console Location 3 28 1 1 Slot Port Property LCO Port Programming Manual References None Feature Manual References None Caller ID Detection Enables the PBX to detect a Caller ID signal from the analog CO line Default Enable Value Range Disable Enable Maintenance Console Location 3 28 1 1 Slot Port Property LCO Port Programmin...

Page 234: ... Feature Manual References None Pause Time Specifies the length of a pause Default 1 5 s Value Range 1 5 s 2 5 s 3 5 s 4 5 s Maintenance Console Location 3 28 1 1 Slot Port Property LCO Port Programming Manual References None Feature Manual References 13 1 4 Pause Insertion 8 1 5 Host PBX Access Code Access Code to the Telephone Company from a Host PBX 16 1 5 Special Carrier Access Code 234 PC Pro...

Page 235: ...rnal Feature Access Disconnect Time Specifies the length of time after a CO line is disconnected during which the PBX cannot seize the line Default 1 5 s Value Range 0 5 s 1 5 s 2 0 s 4 0 s 12 0 s Maintenance Console Location 3 28 1 1 Slot Port Property LCO Port Programming Manual References None Feature Manual References 6 1 2 Flash Recall Terminate Document Version 2009 12 PC Programming Manual ...

Page 236: ...Port Property LCO Port Feature Manual References None OUS Takes the port out of service This enables a temporary non use of the port for example for the purpose of repair Default Not applicable Value Range Not applicable Maintenance Console Location 3 29 1 1 Slot Port Property LCO Port Connection Command Programming Manual References 3 28 1 1 Slot Port Property LCO Port Feature Manual References N...

Page 237: ...I type Programming Manual References None Feature Manual References None ISDN CO QSIG Master QSIG Slave T202 Specifies the maximum time that the PBX waits for a reply after resending the request to use an ISDN line as a TIE line Default 20 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References 1...

Page 238: ... T301 Specifies the maximum time that the PBX waits for a reply after making a call to ISDN Default 0 100 ms Value Range 0 18000 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN CO QSIG Master QSIG Slave T302 Specifies the maximum time allowed between each digit on an incoming call Applies to overlap rec...

Page 239: ...fault 40 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN CO QSIG Master QSIG Slave T304 Specifies the maximum time allowed between each digit on an outgoing call Applies to overlap sending Default 300 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 30 1 1 Slot Ca...

Page 240: ... Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN CO QSIG Master QSIG Slave T308 Specifies the maximum time that the PBX waits for a reply after receiving the Release message from ISDN Default 40 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual Refere...

Page 241: ...lave T310 Specifies the maximum time that the PBX waits for a continuance message after receiving the Incoming Call Proceeding message Default 1100 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN CO QSIG Master QSIG Slave T313 Specifies the maximum time that the PBX waits for a...

Page 242: ...lt 0 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN CO QSIG Master QSIG Slave T318 Specifies the maximum time that the PBX waits for a reply after sending the Resume message Default 0 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI ...

Page 243: ...d Property PRI type Programming Manual References None Feature Manual References None ISDN CO QSIG Master QSIG Slave T322 Specifies the maximum time that the PBX waits for a reply after sending the Status enquiry message Default 40 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None Docu...

Page 244: ...G Master QSIG Slave T3D9 Specifies the length of time that the PBX tries to disconnect L2 in Call by Call mode Default 200 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN Extension T200 Specifies the maximum time that the PBX waits for a reply after sending the L2 command to IS...

Page 245: ...st to ISDN Default 10 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN Extension T203 Specifies the length of time to detect no communication status of L2 Default 100 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Document Versio...

Page 246: ...operty PRI type Programming Manual References None Feature Manual References None ISDN Extension T302 Specifies the maximum time allowed between each digit on an incoming call Applies to overlap receiving Default 150 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None 246 PC Programming ...

Page 247: ... T304 Specifies the maximum time allowed between each digit on an outgoing call Applies to overlap sending Default 200 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN Extension T305 Specifies the maximum time that the PBX waits for a reply after sending the DISC disconnection m...

Page 248: ...when inband tones are supplied Default 300 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN Extension T307 Specifies the maximum time that the PBX maintains a suspended call before restarting Default 1800 100 ms Value Range 0 6000 100 ms Maintenance Console Location 3 30 1 1 Slo...

Page 249: ...ard Property PRI type Programming Manual References None Feature Manual References None ISDN Extension T309 Specifies the length of time that the PBX tries to disconnect the data link before disconnecting the call Default 120 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None Document ...

Page 250: ...xtension T312 Specifies the maximum time that the PBX waits for a reply after sending the SETUP call setting message to ISDN Default 60 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN Extension T316 Specifies the maximum time that the PBX waits for a reply after sending the Rest...

Page 251: ... Range 0 3000 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None ISDN Extension T322 Specifies the maximum time that the PBX waits for a reply after sending the Status enquiry message Default 40 100 ms Value Range 0 600 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Document Version 20...

Page 252: ...ard Property PRI type Programming Manual References None Feature Manual References None ISDN Extension T3D9 Specifies the length of time that the PBX tries to disconnect L2 in Call by Call mode Default 200 100 ms Value Range 0 3000 100 ms Maintenance Console Location 3 30 1 1 Slot Card Property PRI type Programming Manual References None Feature Manual References None 252 PC Programming Manual Doc...

Page 253: ...on 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Document Version 2009 12 PC Programming Manual 253 3 31 1 1 Slot...

Page 254: ... 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References 9 1 16 ISDN INTEGRATED SERVICES DIGITAL NETWORK FEATURES 13 1 20 PRIVATE NETWORK FEATURES QSIG Connection Indicates the port status reference only This column offers two ways to open the screen to select the port command Click the desired cell in the column Select the desired cell in the column and t...

Page 255: ...s Message when an error Option or Mandatory is detected Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Status Receive Selects what happens to a call when the Status Message from the network does not match the actual status of the call Default Ignore Value Range Ignore Ignore the Status Message from the network Dis...

Page 256: ...rame Sequence Selects the type of frame sequence for the port Default Extend Multi frame ESF Value Range Extend Multi frame ESF 4 Frame Multi frame F4 12 Frame Multi frame F12 Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None CO Setting CO Setting parameters are not applicable to ports assigned as Extension in Port T...

Page 257: ...Range Port number Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Port Type Selects the port type Note Each ISDN connection in a QSIG network must have a master port on one PBX and a slave port on another PBX ISDN extensions can belong to an incoming call distribution group or idle extension hunting group In this c...

Page 258: ... to open the screen to select the port command Click the desired cell in the column Select the desired cell in the column and then click Command Default Current status Value Range INS The port is in service OUS The port is out of service Fault The port is not communicating with the network Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References 3 32 1 1 Slot...

Page 259: ...le Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None ISDN In Out Call Type Selects the method used to send dialed digits to the network Default CO port En bloc QSIG slave master port Overlap Value Range En bloc The PBX sends all of the dialed digits at once after the extension user completes dialing The PBX recognize...

Page 260: ...o connected PBXs in a network This setting is only available when Port Type on this screen has been set to QSIG Slave or QSIG Master Default No Value Range No Yes Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References Section 11 9 Private Network Feature Manual References 13 1 17 Private Network Features NDSS Network Direct Station Selection Loopback Test s...

Page 261: ...slot position reference only Default Current slot number Value Range Slot number Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Document Version 2009 1...

Page 262: ...o private network slave port QSIG Master For connecting to private network master port Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Connection Indicates the port status reference only This column offers two ways to open the screen to select the port command Click the desired cell in the column Select the desired...

Page 263: ...nsion for MSN Ring all ISDN extensions that are addressed with MSN Ring AN Extension for MSN Ring only one of the ISDN extensions that are addressed with MSN Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Network Configuration Slot Indicates the slot position reference only Default Current slot number Value Range ...

Page 264: ...ork must have a master port on one PBX and a slave port on another PBX ISDN extensions can belong to an incoming call distribution group or idle extension hunting group In this case an MSN can be assigned Default CO Value Range CO For connecting to public network Extension For connecting to extension QSIG Slave For connecting to private network slave port QSIG Master For connecting to private netw...

Page 265: ...municating with the network Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References 3 32 1 1 Slot Port Property PRI Port Connection Command Feature Manual References None Network Type Selects the network type of the port Default 51 US National ISDN 2 Value Range 0 56 2 UK Domestic 5 Netherlands 6 SwissNET2 7 SwissNET3 8 Euro ISDN Standard 14 France Domestic ...

Page 266: ...ntenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None 266 PC Programming Manual Document Versio...

Page 267: ...Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Connection Indicates the port status reference only This column offers two ways to open the screen to select the port command Click the desired cell in the column Select the desired cell in the column and then click Command Default Current status Value Range INS The p...

Page 268: ...TE NETWORK FEATURES Calling Party Number Numbering Plan ID Public Private Selects the numbering plan ID that applies to outgoing CO line calls routed through public and private networks Default Public Unknown Private Private Value Range Unknown ISDN Telephony National Standard Private Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manua...

Page 269: ... Private Selects the numbering plan ID that applies to incoming CO line calls routed through public and private networks Default Public Unknown Private Private Value Range Unknown ISDN Telephony National Standard Private Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Called Party Number Type of Number Public Priva...

Page 270: ...Slot Indicates the slot position reference only Default Current slot number Value Range Slot number Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number 270 PC Programming Manual Document Version 2009 12 3 31 1 1 Slot Port ...

Page 271: ...necting to public network Extension For connecting to extension QSIG Slave For connecting to private network slave port QSIG Master For connecting to private network master port Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References None Connection Indicates the port status reference only This column offers two ways to open th...

Page 272: ... Rerouting to No Default CLIR E911 Yes Other services No Value Range No Yes Maintenance Console Location 3 31 1 1 Slot Port Property PRI Port Programming Manual References None Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation 13 1 21 Private Network Features QSIG CCBS Completion of Calls to Busy Subscriber 13 1 22 Private Network Features QSIG CF Call Forwarding 13 1 ...

Page 273: ...Port Property PRI Port Feature Manual References None OUS Takes the port out of service This enables a temporary non use of the port for example for the purpose of repair Default Not applicable Value Range Not applicable Maintenance Console Location 3 32 1 1 Slot Port Property PRI Port Connection Command Programming Manual References 3 31 1 1 Slot Port Property PRI Port Feature Manual References N...

Page 274: ... None Feature Manual References None Frame Sequence Selects the type of frame sequence used for communications Default ESF Value Range D4 ESF Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None ESF Frame Sequence Selects the values for C bit and D bit To enable this setting Frame Sequence on this screen should be set to...

Page 275: ...ing level Transmit Pulse Amplitude of LIU Default Mode 1 Value Range Mode 1 Mode 8 Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None LIU Receive Option Selects the receiving level Receive Equalization of LIU Default Automatic Value Range Automatic 6 dB 12 dB 18 dB 24 dB Document Version 2009 12 PC Programming Manual 2...

Page 276: ... Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None First Dial Timer DID TIE Specifies the minimum time that the PBX waits after seizing a DID or TIE line before sending the dialed digits to the telephone company or to another PBX This allows the telephone company or the other PBX to have enough time to accept the dial...

Page 277: ...s Value Range 32 n n 1 255 ms Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None Wink Signal Width Specifies the length of a wink signal Default 224 ms Value Range 32 n n 4 9 ms Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None Document Ve...

Page 278: ...gramming Manual References None Feature Manual References None DTMF Tone DTMF Transmit Specifies the volume of the DTMF tone to be transmitted Default 3 dB Value Range 3 n n 0 15 dB Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None DTMF Tone DTMF Receive Specifies the volume of the DTMF tone to be received Default 26 ...

Page 279: ... hook signal in a pulse dial Default 60 Value Range 60 67 Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None Pulse Dial Pulse Type Selects the type of pulse dial transmission appropriate to your area Default Normal Value Range Normal Sweden New Zealand Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Do...

Page 280: ...e Programming Manual References None Feature Manual References None Pulse Dial CO Feed Back Tone Specifies whether the pulse feedback tone is turned on or not For outgoing CO line calls audible tones can be heard as the dialed number is sent out which informs the extension user that the number has been dialed Default Yes Value Range No Yes Maintenance Console Location 3 33 1 1 Slot Card Property T...

Page 281: ...MAKE Width Specifies the minimum length of the make signal in a pulse dial Default 8 ms Value Range 8 n n 1 5 ms Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None Flash Flash Signal Detection OPX Enables the PBX to detect hookswitch flash signals from an SLT connected to an OPX Default Enable Value Range Disable Enabl...

Page 282: ...ce Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None Flash Flash Width OPX Specifies the maximum length of a flash signal sent from an SLT connected to an OPX that the PBX can recognize as a hookswitch flash signal Default 800 ms Value Range 8 n n 3 191 ms Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programmi...

Page 283: ...inimum BREAK Width TIE Specifies the minimum length of the break signal in a flash signal sent from a TIE line Default 200 ms Value Range 8 n n 3 63 ms Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References None Flash Flash Width TIE Specifies the maximum length of a flash signal received from a TIE line that the PBX can recogn...

Page 284: ...ect the beginning of a Caller ID series Default Value Range A D Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References 3 1 3 Caller ID Caller ID Caller ID Information End Code Selects the delimiter used to separate multiple parameters in a Caller ID series Default Value Range A D 284 PC Programming Manual Document Version 2009 ...

Page 285: ...ller ID Caller ID End Code Selects the DTMF code used to detect the end of a Caller ID series Default Value Range A D Maintenance Console Location 3 33 1 1 Slot Card Property T1 type Programming Manual References None Feature Manual References 3 1 3 Caller ID Document Version 2009 12 PC Programming Manual 285 3 33 1 1 Slot Card Property T1 type ...

Page 286: ...1 Slot Port Property T1 Port Programming Manual References None Feature Manual References None CH Indicates the channel number reference only Default Current channel number Value Range Channel number Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port Programming Manual References None Feature Manual References None Connection Indicates the channel status reference only 286 PC Program...

Page 287: ...lot Port Property T1 Port Programming Manual References None Feature Manual References None Subscriber Number Specifies the number used as the CLIP number Default Not stored Value Range Max 16 digits consisting of 0 9 and Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port Programming Manual References None Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation...

Page 288: ...ffice LCOT Loop Start Central Office DID Direct Inward Dialing TIE TIE Line OPX Off Premise Extension Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port Programming Manual References None Feature Manual References 17 1 1 T1 Line Service Trunk Property Selects the CO line property of the TIE channel Default Public Value Range Public Use the DIL DID method to distribute incoming CO lin...

Page 289: ...ected This setting is only available when Channel Type on this screen is set to DID Default 160 ms Value Range None 80 n n 2 75 ms Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port Programming Manual References None Feature Manual References 3 1 22 CPC Calling Party Control Signal Detection CPC Signal Detection LCO GCO Outgoing Incoming Specifies the length of time required by the P...

Page 290: ... T1 channel Default 80 ms Value Range 80 ms 160 ms Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port Programming Manual References None Feature Manual References None CO Pulse Speed Selects the speed at which pulse dials are sent to the T1 channel Default 10 pulse s Value Range 10 pulse s 20 pulse s Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port 290 PC Programming ...

Page 291: ...n 3 34 1 1 Slot Port Property T1 Port Programming Manual References None Feature Manual References None Start Signal Type Selects the type of the start signal Default Wink Value Range Immediate Sends the dialed digits to the CO line when the First Dial Timer expires Wink Sends the dialed digits to the CO line when the wink signal is received Maintenance Console Location 3 34 1 1 Slot Port Property...

Page 292: ...formation is received when the channel type is TIE Default Yes Value Range Yes No Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port Programming Manual References None Feature Manual References None Ringback Tone to Outside Caller Enables the PBX to send a ringback tone to an outside caller when the network cannot send the tone This setting is only available when Channel Type on this...

Page 293: ... the network cannot send the tone Default Disable Value Range Disable Enable Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port Programming Manual References None Feature Manual References None Pause Time Specifies the length of a pause Default 1 5 s Value Range 1 5 s 2 5 s 3 5 s 4 5 s Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port Document Version 2009 12 PC Progra...

Page 294: ...ot Port Property T1 Port Programming Manual References None Feature Manual References 5 1 1 EFA External Feature Access Disconnect Time Specifies the length of time after a CO line is disconnected during which the PBX cannot seize the line Default 1 5 s Value Range 0 5 s 1 5 s 2 0 s 4 0 s 12 0 s Maintenance Console Location 3 34 1 1 Slot Port Property T1 Port Programming Manual References None Fea...

Page 295: ...t Port Property T1 Port Feature Manual References None OUS Takes the channel out of service This enables a temporary non use of the port for example for the purpose of repair Default Not applicable Value Range Not applicable Maintenance Console Location 3 35 1 1 Slot Port Property T1 Port Connection Command Programming Manual References 3 34 1 1 Slot Port Property T1 Port Feature Manual References...

Page 296: ...ndicates the slot position reference only Default Current slot number Value Range Slot number Maintenance Console Location 3 36 1 1 Slot OPB3 Card Property Programming Manual References None Feature Manual References None Sub Slot Indicates the sub slot number reference only Default Current sub slot number Value Range Sub slot number Maintenance Console Location 3 36 1 1 Slot OPB3 Card Property Pr...

Page 297: ...Feature Manual References None Status Indicates the status of the option card in each slot reference only This column offers two ways to open the screen to select the card command Click the desired cell in the column Select the desired cell in the column and then click Command Default Current status Value Range INS The card is in service OUS The card is out of service Fault The card has been remov...

Page 298: ... References None Feature Manual References None Port Status Indicates the port status of the mounted option card reference only Default Current port status Value Range INS The card is in service OUS The card is out of service Fault The card is pulled out from the sub slot or is not communicating with the PBX Maintenance Console Location 3 36 1 1 Slot OPB3 Card Property Programming Manual Reference...

Page 299: ... Time Specifies the length of time after the sensor has been triggered during which any further input from the sensor will be ignored Default 10 s Value Range 10 n n 1 255 s Maintenance Console Location 3 36 1 1 Slot OPB3 Card Property Programming Manual References 7 7 5 5 External Sensor Feature Manual References 5 1 9 External Sensor SVM Feature Specifies whether or not to use the ESVM card for ...

Page 300: ...or not to use the ESVM card as an MSG card It is possible to use the ESVM card for the SVM feature as an MSG card OGM feature or both Default Enable Value Range Disable Enable Maintenance Console Location 3 36 1 1 Slot OPB3 Card Property Programming Manual References 3 5 1 1 Slot OPB3 Card Property MSG Feature Feature Manual References 12 1 2 OGM Outgoing Message 16 1 8 SVM Simplified Voice Messag...

Page 301: ... 37 1 1 Slot OPB3 Card Property Card Command Programming Manual References None Feature Manual References None OUS Takes the card out of service Default Not applicable Value Range Not applicable Maintenance Console Location 3 37 1 1 Slot OPB3 Card Property Card Command Programming Manual References None Feature Manual References None Document Version 2009 12 PC Programming Manual 301 3 37 1 1 Slot...

Page 302: ...37 1 1 Slot OPB3 Card Property Card Command Installation Manual References 1 2 1 Optional Equipment Programming Manual References None Feature Manual References None Delete Assigns the card type to be deleted from the sub slot Default Not applicable Value Range Not applicable Maintenance Console Location 3 37 1 1 Slot OPB3 Card Property Card Command Programming Manual References None Feature Manua...

Page 303: ... Input Output Card ESVM4 4 Channel Simplified Voice Message Card Maintenance Console Location 3 38 1 1 Slot OPB3 Option Card Setup Installation Manual References 1 2 1 Optional Equipment Programming Manual References 3 36 1 1 Slot OPB3 Card Property Feature Manual References None Slot 1 Slot 3 Selects the slot on the OPB3 card to install or remove the option card for Default Slot 1 Value Range Not...

Page 304: ... Card DPH4 4 Port Doorphone Card ECHO16 16 Channel Echo Canceller Card EIO4 4 Port External Input Output Card ESVM4 4 Channel Simplified Voice Message Card Maintenance Console Location 3 38 1 1 Slot OPB3 Option Card Setup Programming Manual References 3 1 1 1 Slot 3 36 1 1 Slot OPB3 Card Property Feature Manual References None 304 PC Programming Manual Document Version 2009 12 3 38 1 1 Slot OPB3 O...

Page 305: ...e registration Follow the steps below to de register the PS 1 Click De registration A dialog box will appear Registered extension numbers and names are displayed on the left 2 Highlight numbers and names and click the right arrow to select them for de registration Click Next A dialog box will appear 3 Click Confirm If the de registration is successful the dialog box will show De registration succe...

Page 306: ...e only Default Not applicable Value Range 1 64 Maintenance Console Location 3 39 1 2 Portable Station Programming Manual References None Feature Manual References 13 1 26 PS Connection Extension No Specifies the extension number of the PS In Wireless XDP Parallel Mode the PS can be used as a sub telephone with a wired main telephone PT SLT and two of them will share one extension number of the mai...

Page 307: ...ies the name of the PS Default Not stored Value Range Max 20 characters Maintenance Console Location 3 39 1 2 Portable Station Programming Manual References 6 10 4 2 1 Portable Station Extension Settings Main Extension Name Feature Manual References 13 1 26 PS Connection Status Indicates whether a certain PS is registered reference only Default None Value Range None Registered Document Version 200...

Page 308: ...nance Console Location 3 39 1 2 Portable Station Programming Manual References None Feature Manual References 13 1 26 PS Connection 308 PC Programming Manual Document Version 2009 12 3 39 1 2 Portable Station ...

Page 309: ...matically when a CS is connected to the PBX Without the Radio System ID PSs cannot be registered System Wireless System ID Indicates the radio system ID used to register a PS reference only Default Not stored Value Range Not applicable Maintenance Console Location 3 40 1 3 Option Programming Manual References None Feature Manual References None New Card Installation Card Status for any Card Select...

Page 310: ...mode or T1 LCOT mode when it is installed for the first time Default ISDN Standard mode Value Range ISDN Standard mode The CCBS CF CT and Centralized VM features are supported DIL and DID call distribution are available for the D channel T1 LCOT mode DIL and DID call distribution are available for all 23B channels The CCBS CF CT and Centralized VM features are not available in this mode Maintenanc...

Page 311: ...res QSIG CF Call Forwarding 13 1 24 Private Network Features QSIG CT Call Transfer 13 1 21 Private Network Features QSIG CCBS Completion of Calls to Busy Subscriber Document Version 2009 12 PC Programming Manual 311 3 40 1 3 Option ...

Page 312: ...ish a private network TIE line service QSIG network etc without being connected through the telephone company assign only one PBX as the clock source on the network That PBX should have a card connected to a telephone company line selected as its clock source All other PBXs should have cards connected to the network selected as the clock source This enables all PBXs on the network to synchronize t...

Page 313: ...Section 4 2 System Document Version 2009 12 PC Programming Manual 313 ...

Page 314: ...red by clicking the parameter you want to change and typing the new value or by clicking the up down arrows beside the date and time Default Current date and time Value Range Year 2000 2099 Month 01 12 Day 01 31 Hour 00 23 Minute 00 59 Second 00 59 Maintenance Console Location 4 1 2 1 1 Date Time Date Time Settings Programming Manual References None Feature Manual References None 314 PC Programmin...

Page 315: ...he time information provided by the network Default Disable Value Range Disable ISDN Caller ID FSK SNTP Maintenance Console Location 4 2 2 1 2 Date Time SNTP Daylight Saving Programming Manual References None Feature Manual References 1 1 7 Automatic Time Adjustment SNTP SNTP Server IP Address Specifies the IP address of an SNTP server Default Not stored Value Range 1 0 0 0 223 255 255 255 Mainten...

Page 316: ...our local UTC Coordinated Universal Time time zone using the up and down arrows Default 0 00 Value Range 14 00 14 00 Maintenance Console Location 4 2 2 1 2 Date Time SNTP Daylight Saving Programming Manual References None Feature Manual References 1 1 7 Automatic Time Adjustment SNTP Time Zone Time Zone for PC Indicates the UTC Coordinated Universal Time time zone of the PC reference only Default ...

Page 317: ...on 4 2 2 1 2 Date Time SNTP Daylight Saving Programming Manual References None Feature Manual References 1 1 7 Automatic Time Adjustment Document Version 2009 12 PC Programming Manual 317 4 2 2 1 2 Date Time SNTP Daylight Saving ...

Page 318: ...References 4 2 2 1 2 Date Time SNTP Daylight Saving Feature Manual References 1 1 7 Automatic Time Adjustment Start Date Year Month Day Specifies the start date of daylight savings time Default Year 2008 For Daylight Saving Time number 1 The year advances by one for the subsequent Daylight Saving Times Month 3 Day Day of the second Sunday of the month Value Range Year 2000 2099 Month 1 12 Day 1 31...

Page 319: ...t Saving Times Month 11 Day Day of the first Sunday of the month Value Range Year 2000 2099 Month 1 12 Day 1 31 Maintenance Console Location 4 3 2 1 2 Date Time SNTP Daylight Saving Daylight Saving Programming Manual References 4 2 2 1 2 Date Time SNTP Daylight Saving Feature Manual References 1 1 7 Automatic Time Adjustment Document Version 2009 12 PC Programming Manual 319 4 3 2 1 2 Date Time SN...

Page 320: ...isting of 0 9 Maintenance Console Location 4 4 2 2 Operator BGM Programming Manual References 4 6 2 4 Week Table 4 9 2 6 1 Numbering Plan Main 5 12 3 5 1 Incoming Call Distribution Group Group Settings Feature Manual References 12 1 5 Operator Features BGM and Music on Hold Music Source of BGM Selects the audio source of BGM Default Internal BGM 1 Value Range External BGM Internal BGM 1 Internal B...

Page 321: ...1 BGM Background Music 11 1 4 Music on Hold 12 1 2 OGM Outgoing Message BGM and Music on Hold Music Source of BGM2 7 Card Selects the card IPCMPR ESVM Circuit or ESVM of the audio source of BGM Cards must have the MSG Feature setting enabled to be available for selection Default None Value Range Available cards Maintenance Console Location 4 4 2 2 Operator BGM Programming Manual References 3 5 1 1...

Page 322: ...4 Music on Hold BGM and Music on Hold Sound on Transfer Selects the audio source for Music for Transfer either the same music source chosen for the Music on Hold or ringback tone Default Same as Music on Hold Value Range Same as Music on Hold Ringback Tone Maintenance Console Location 4 4 2 2 Operator BGM Programming Manual References None Feature Manual References 3 1 10 Call Transfer 322 PC Prog...

Page 323: ... Manual References 15 1 1 Redial Last Number Automatic Redial Redial Call Ring Duration Specifies the length of time that the PBX waits for the called party to answer an Automatic Redial attempt This is the length of time that the called party s extension will ring for each attempt Default 30 s Value Range 10 n n 1 30 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual Refere...

Page 324: ...Dial Hot Line Pickup Dial Start Specifies the length of time between going off hook and the start of automatic dialing when the Hot Line feature is set Default 1 s Value Range 0 15 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References 8 1 6 Hot Line Dial Extension First Digit Specifies the length of time after going off hook within whic...

Page 325: ... s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References 1 1 5 Automatic Extension Release Dial Analog CO First Digit Specifies the length of time within which the first digit of a telephone number must be sent to an analog CO line If no digit is sent before this time expires the PBX recognizes end of dialing and stops muting the caller s...

Page 326: ... dialing and stops muting the caller s voice over the analog CO line Default 5 s Value Range 1 15 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References None Dial Analog CO Call Duration Start Specifies the length of time between the end of dialing and the start of the SMDR timer for outgoing analog CO line calls Default 0 s Value Range ...

Page 327: ... 1 240 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Intercept No Answer Time Intercept No Answer Time Day Lunch Break Night Feature Manual References 9 1 11 Intercept Routing Recall Hold Recall Specifies the length of time until the holding extension receives a Hold Recall ring or alarm tone when a held call remai...

Page 328: ... Portable Station Extension Settings Feature Manual References 3 1 10 Call Transfer Recall Call Park Recall Specifies the length of time that a parked call waits to be retrieved before the Transfer Recall destination assigned to the extension that parked the call hears a Call Park Recall ring Default 60 s Value Range 1 240 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual R...

Page 329: ...hen a call is made to an extension in busy status or DND mode A reorder tone will be sent when this timer expires For a call through DISA the call will be disconnected when this timer expires Default 10 s Value Range 0 continuous 15 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References 4 1 10 DND Do Not Disturb Tone Length Reorder Tone ...

Page 330: ...he PT will return to idle status when this timer expires This setting is applied to PSs as well as PTs Default 3 s Value Range 1 15 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References 1 1 5 Automatic Extension Release 8 1 2 Hands free Operation DISA Door Reminder U Conf DISA Delayed Answer Timer Specifies the length of time that the c...

Page 331: ...8 s Value Range 0 0 12 0 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 7 4 5 3 2 Voice Message DISA Message Feature Manual References 4 1 8 DISA Direct Inward System Access DISA No Dial Intercept Timer Specifies the length of time after the OGM finishes playing in which the caller must begin dialing before the call is redirected to the operator Default 10 s V...

Page 332: ...rd System Access DISA Intercept Timer Day Lunch Break Night Specifies the length of time until an unanswered DISA call is intercepted and redirected to the intercept routing destination after the original destination receives the call in each time mode Default 40 s Value Range 0 60 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 6 1 4 1 1 Wired Extension Extens...

Page 333: ...es 7 4 5 3 2 Voice Message DISA Message Feature Manual References 4 1 8 DISA Direct Inward System Access DISA CO to CO Call Prolong Counter Specifies the number of times that the caller can prolong a CO to CO line call on a DISA line Selecting 0 enables the caller to prolong the CO to CO line call without restriction Default 10 Value Range 0 15 Maintenance Console Location 4 5 2 3 Timers Counters ...

Page 334: ...SA Direct Inward System Access DISA Progress Tone Continuation Time before Recording Message Specifies the length of time that a progress tone is sent to the manager extension before recording an OGM Default 5 s Value Range 0 7 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 7 4 5 3 2 Voice Message DISA Message Feature Manual References 12 1 2 OGM Outgoing Mess...

Page 335: ...l the call is canceled when there is no answer Default 30 s Value Range 10 n n 1 15 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 7 1 5 1 Doorphone Feature Manual References 4 1 12 Doorphone Call Doorphone Call Duration Specifies the length of time until an answered doorphone call is disconnected Default 60 s Value Range 10 n n 0 30 s Maintenance Console Loca...

Page 336: ... Console Location 4 5 2 3 Timers Counters Programming Manual References 7 1 5 1 Doorphone Feature Manual References 4 1 11 Door Open Timed Reminder Repeat Counter Specifies the number of times that an alarm is repeated Default 3 Value Range 1 15 Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References 17 1 4 Timed Reminder 336 PC Programming...

Page 337: ...Duration Specifies the length of time that an alarm rings Default 30 s Value Range 10 n n 1 30 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References 17 1 4 Timed Reminder Unattended Conference Recall Start Timer Specifies the length of time until the conference originator receives an Unattended Conference Recall tone Default 10 Value Ra...

Page 338: ... the conference Default 30 s Value Range 0 240 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References 3 1 18 Conference Unattended Conference Disconnect Timer Specifies the length of time until an Unattended Conference is disconnected after the parties involved in the conference receive a warning tone but the conference originator does n...

Page 339: ...sole Location 4 5 2 3 Timers Counters Programming Manual References 8 1 6 1 System Speed Dial 5 3 3 1 3 Caller ID Modification Feature Manual References 3 1 3 Caller ID Caller ID Visual Caller ID Display Specifies the length of time that a Caller ID number with the Call Waiting tone offered by an analog line from the telephone company is shown on the display The Caller ID number flashes on the dis...

Page 340: ...fault None Value Range None 1 15 Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References 20 1 1 Walking COS 19 1 1 Verification Code Entry 5 1 6 Extension PIN Personal Identification Number External Sensor Ring Duration Specifies the length of time that the PBX waits for the called party to answer before canceling a sensor call Default 30 s...

Page 341: ...References 12 3 10 3 DID Table Feature Manual References 4 1 6 DID Direct Inward Dialing Incoming Call Inter digit Timer TIE Specifies the length of time between digits when receiving a dialed number from a TIE line The call will be redirected to a PBX operator when this timer expires Default 10 s Value Range 3 30 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References...

Page 342: ...n an ongoing call after air synchronization is lost Default 300 Value Range 60 n n 0 300 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 5 26 3 10 Air Synchronization Group 13 6 11 5 Air Synchronization Feature Manual References None Voice Mail Caller from VM to CO On hook Wait Time Specifies the length of time from when the VPS seizes a CO line for example to ...

Page 343: ...m a PT or PS during a conversation Default 160 ms Value Range 80 ms 160 ms 240 ms 320 ms Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References None Feature Manual References None During Conversation DTMF Inter digit Pause Specifies the length of time between DTMF signals when numbers are dialed in succession from a PT or PS during a conversation Default 112 ms Value Ra...

Page 344: ...ual References None Feature Manual References 13 1 4 Pause Insertion System Wireless PS Out of Range Timer When the destination of an incoming call is a PS specifies the length of time the PBX searches for the PS before setting its status to Out of Range If 0 is assigned the timer is controlled by the cell station Default 0 s Value Range 0 s 4 s 8 s Maintenance Console Location 4 5 2 3 Timers Coun...

Page 345: ... Message Feature Manual References 16 1 8 SVM Simplified Voice Message SVM Dial Tone Continuous Time Specifies the length of time that dial tone 3 is heard after all messages stored by the SVM feature for an extension are finished playing Default 5 s Value Range 1 60 s Maintenance Console Location 4 5 2 3 Timers Counters Programming Manual References 6 9 4 1 7 Wired Extension Simplified Voice Mess...

Page 346: ...Select the desired Time Table from the Time Table No list When in Automatic Switching mode the time modes of the tenant are switched as programmed in the corresponding Time Table Manual switching is possible only from an authorized extension determined by COS To adjust the currently displayed Time Table click and drag the divisions between two time periods To program the time blocks of the current...

Page 347: ...e Console Location 4 7 2 4 Week Table Time Setting Programming Manual References None Feature Manual References 17 1 3 Tenant Service 17 1 5 Time Service 1 Day Lunch Night Day1 Start Lunch Start Day2 Start Night Start Hour Minute Specifies the start time for each time block Times can only be set when 1 Day Lunch Night Day1 Start Lunch Start Day2 Start Night Start Setting is set to Enable Default D...

Page 348: ...re Manual References 17 1 3 Tenant Service 17 1 5 Time Service 2 Break Break 1 3 Start Hour Minute Specifies the start time for each break period Times can only be set when 2 Break Break 1 3 Start Setting is set to Enable Default 00 00 Value Range 00 00 23 59 Maintenance Console Location 4 7 2 4 Week Table Time Setting Programming Manual References None Feature Manual References 17 1 3 Tenant Serv...

Page 349: ...k 1 3 Start Setting is set to Enable Default 00 00 Value Range 00 01 23 59 Maintenance Console Location 4 7 2 4 Week Table Time Setting Programming Manual References None Feature Manual References 17 1 3 Tenant Service 17 1 5 Time Service Document Version 2009 12 PC Programming Manual 349 4 7 2 4 Week Table Time Setting ...

Page 350: ... the holiday Default Disable Value Range Disable Enable Maintenance Console Location 4 8 2 5 Holiday Table Programming Manual References None Feature Manual References 17 1 5 Time Service Holiday Table Start Date Month Specifies the month of the holiday start date Default 1 Value Range 1 12 Maintenance Console Location 4 8 2 5 Holiday Table Programming Manual References None Feature Manual Referen...

Page 351: ...1 5 Time Service Holiday Table End Date Month Specifies the month of the holiday end date Default 1 Value Range 1 12 Maintenance Console Location 4 8 2 5 Holiday Table Programming Manual References None Feature Manual References 17 1 5 Time Service Holiday Table End Date Day Specifies the day of the holiday end date Default 1 Value Range 1 31 Document Version 2009 12 PC Programming Manual 351 4 8 ...

Page 352: ...aintenance Console Location 4 8 2 5 Holiday Table Programming Manual References None Feature Manual References 17 1 5 Time Service 352 PC Programming Manual Document Version 2009 12 4 8 2 5 Holiday Table ...

Page 353: ...ing Scheme 03 3 Extension Numbering Scheme 04 4 Extension Numbering Scheme 21 5 Extension Numbering Scheme 22 6 Extension Numbering Scheme 05 20 23 64 Not stored Value Range Max 3 digits consisting of 0 9 Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 5 12 3 5 1 Incoming Call Distribution Group Group Settings 5 19 3 7 2 VM DPT Group Unit Settings 5 22 3 8 ...

Page 354: ...dial tone Operator Call Specifies the feature number used to call the operator Default 0 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 4 2 2 Operator BGM 8 6 6 6 Tenant Feature Manual References 12 1 5 Operator Features Idle Line Access Local Access Specifies the feature number used to make a CO line call b...

Page 355: ...e a CO line call using an idle CO line from a certain trunk group Default 8 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 12 1 10 1 CO Line Settings Feature Manual References 3 1 16 CO Line Access TIE Line Access Specifies the feature number used to make a TIE line call Default 7 Value Range Max 4 digits cons...

Page 356: ...1 Numbering Plan Main Programming Manual References None Feature Manual References 15 1 1 Redial Last Number System Speed Dialing Personal Speed Dialing Specifies the feature number used to make a call using a System Personal Speed Dialing number Default Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 6 4 4 1 3...

Page 357: ...mming Manual References None Feature Manual References 16 1 6 Speed Dialing Personal Doorphone Call Specifies the feature number used to make a call to a doorphone Default 31 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 7 1 5 1 Doorphone Feature Manual References 4 1 12 Doorphone Call Group Paging Specifies ...

Page 358: ... Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 4 2 2 Operator BGM 4 12 2 7 1 Class of Service COS Settings Programming Manager Manager Feature Manual References 2 1 1 BGM Background Music OGM Record Clear Playback Specifies the feature number available for manager extensions used to record clear or play back a ce...

Page 359: ...consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 12 1 10 1 CO Line Settings Feature Manual References 3 1 16 CO Line Access Parallel Telephone Ring Mode Set Cancel Specifies the feature number used to set or cancel an SLT connected in parallel with a DPT to ring when receiving an incoming call Default 39 Value Range Max 4 digits consist...

Page 360: ...pecifies the feature number used to answer a call ringing at a certain extension Default 41 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 3 Call Pickup Deny 6 10 4 2 1 Portable Station Extension Settings Option 3 Call Pickup Deny Feature Manual References 3 ...

Page 361: ...r used to answer a page to a paging group Default 43 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 5 9 3 4 Paging Group Feature Manual References 13 1 1 Paging Automatic Callback Busy Cancel Specifies the feature number used to cancel Automatic Callback Busy Default 46 Value Range Max 4 digits consisting of 0...

Page 362: ...e Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 12 2 7 1 Class of Service COS Settings Optional Device Other Extensions Remote Operation by Other Extension Feature Manual References 20 1 1 Walking COS 19 1 1 Verification Code Entry Wireless XDP Parallel Mode Set Cancel Specifies the feature number used to set or cancel...

Page 363: ...ntenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References None Feature Manual References 1 1 2 Account Code Entry Call Hold Call Hold Retrieve Specifies the feature number used to hold a call or retrieve a call on hold from the holding extension Default 50 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programmi...

Page 364: ...all Park Retrieve Specifies the feature number used to hold a call in a parking zone or retrieve a call held in a parking zone Default 52 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References None Feature Manual References 3 1 7 Call Park Hold Retrieve Specified with a Held CO Line Number Specifies the feature number...

Page 365: ...nge Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 7 1 5 1 Doorphone Feature Manual References 4 1 11 Door Open External Relay Access Specifies the feature number used to activate a relay Default 56 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Document Version 2...

Page 366: ... EFA External Feature Access COLR Set Cancel Specifies the feature number used to set or cancel COLR which suppresses the presentation of the called party s number to the caller Default 7 0 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 3 31 1 1 Slot Port Property PRI Port Supplementary Service COLP CLIR COLR ...

Page 367: ... 1 15 CLIP Calling Line Identification Presentation 13 1 23 Private Network Features QSIG CLIP COLP Calling Connected Line Identification Presentation and CNIP CONP Calling Connected Name Identification Presentation Switch CLIP of CO Line Extension Specifies the feature number used to send either the CLIP number of the CO line in use subscriber s number or the extension to the network Default 7 2 ...

Page 368: ...g Manual References None Feature Manual References None Message Waiting Set Cancel Call Back Specifies the feature number used to set or cancel Message Waiting or call back the caller Default 70 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References None Feature Manual References 11 1 3 Message Waiting FWD DND Set Can...

Page 369: ...for incoming CO line calls Default 711 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 6 3 4 1 2 Wired Extension FWD DND 6 12 4 2 2 Portable Station FWD DND Feature Manual References 6 1 6 FWD Call Forwarding FWD DND Set Cancel Call from Extension Specifies the feature number used to set or cancel FWD DND for i...

Page 370: ...intenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 6 3 4 1 2 Wired Extension FWD DND 6 12 4 2 2 Portable Station FWD DND Feature Manual References 6 1 6 FWD Call Forwarding Group FWD Set Cancel Call from CO Extension Specifies the feature number used to set or cancel FWD for incoming CO line and intercom calls to an incoming call distribution group Default 714 V...

Page 371: ...nual References 5 12 3 5 1 Incoming Call Distribution Group Group Settings Feature Manual References 6 1 6 FWD Call Forwarding Group FWD Set Cancel Call from Extension Specifies the feature number used to set or cancel FWD for incoming intercom calls to an incoming call distribution group Default 716 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Pl...

Page 372: ...Pickup Paging Deny Set Cancel Specifies the feature number used to set or cancel Paging Deny i e preventing other extensions from paging your extension Default 721 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 5 9 3 4 Paging Group Feature Manual References 13 1 1 Paging Walking Extension Specifies the feature...

Page 373: ...ions during data transmission Default 730 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References None Feature Manual References 4 1 1 Data Line Security Manual Call Waiting for Extension Call Specifies the feature number used to set or change the method of receiving a Call Waiting notification from an extension Defaul...

Page 374: ...ation 4 9 2 6 1 Numbering Plan Main Programming Manual References None Feature Manual References 3 1 11 CALL WAITING FEATURES Executive Override Deny Set Cancel Specifies the feature number used to set or cancel Executive Busy Override i e preventing other extensions from joining your conversation Default 733 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Num...

Page 375: ...eferences 5 12 3 5 1 Incoming Call Distribution Group Group Settings Feature Manual References 9 1 3 ICD Group Features Log in Log out Log in Log out Specifies the feature number used to join or leave an incoming call distribution group Default 736 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 5 12 3 5 1 Inco...

Page 376: ...ferences 9 1 7 ICD Group Features Supervisory Hot Line Pickup Dial Program Set Cancel Specifies the feature number used to set cancel the Hot Line feature or program the number to be automatically dialed Default 740 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 5 2 3 Timers Counters Dial IRNA Recall Tone Di...

Page 377: ...Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 4 2 2 Operator BGM Feature Manual References 2 1 1 BGM Background Music Remote Timed Reminder Remote Wakeup Call Specifies the feature number used to set or cancel a Timed Reminder remotely Wake up Call Default 76 Value Range Max 4 digits consisting of 0 9 and Mainten...

Page 378: ...erences None Feature Manual References 17 1 4 Timed Reminder Printing Message Specifies the feature number used to select a Printing Message to be output on SMDR Default 761 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 8 2 6 2 Hotel Main SMDR for External Hotel Application 2 Printing Message 1 8 Feature Manu...

Page 379: ...ber available for manager extensions used to change the time mode manually Default 780 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 12 2 7 1 Class of Service COS Settings Programming Manager Time Service Switch 4 12 2 7 1 Class of Service COS Settings Programming Manager Manager Feature Manual References 1...

Page 380: ...l Lock feature Default 783 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 4 12 2 7 1 Class of Service COS Settings Programming Manager Manager Feature Manual References 5 1 4 Extension Dial Lock Extension Feature Clear Specifies the feature number used to reset certain features of an extension to the default v...

Page 381: ...References None Feature Manual References 5 1 6 Extension PIN Personal Identification Number Dial Information CTI Specifies the feature number used to send dial information to the CTI feature instead of the PBX Default Not stored Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References None Feature Manual References 3 1...

Page 382: ...cord listen to and delete messages Default 38 Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 6 9 4 1 7 Wired Extension Simplified Voice Message 6 16 4 2 5 Portable Station Simplified Voice Message Feature Manual References 16 1 8 SVM Simplified Voice Message Other PBX Extension Other PBX extension numbers can ...

Page 383: ...x 3 digits consisting of 0 9 and Maintenance Console Location 4 9 2 6 1 Numbering Plan Main Programming Manual References 11 1 9 1 TIE Table Leading Number Feature Manual References 13 1 15 PRIVATE NETWORK FEATURES Document Version 2009 12 PC Programming Manual 383 4 9 2 6 1 Numbering Plan Main ...

Page 384: ...t work Specifies whether to check if the quick dial numbering plan is compatible does not overlap with the main numbering plan Default Disable Value Range Disable Checks whether the quick dial numbering plan is compatible with the main numbering plan Enable Does not check whether the quick dial numbering plan is compatible with the main numbering plan Maintenance Console Location 4 10 2 6 2 Number...

Page 385: ...Dialing number is used Default Not stored Value Range Max 32 digits consisting of 0 9 T Transfer Secret P Pause and F Flash Maintenance Console Location 4 10 2 6 2 Numbering Plan Quick Dial Programming Manual References None Feature Manual References 13 1 25 Private Network Features VoIP Voice over Internet Protocol 6 1 4 Flexible Numbering Fixed Numbering 14 1 1 Quick Dialing Document Version 200...

Page 386: ...rogramming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 2 Manual C Waiting for Extension Call 6 10 4 2 1 Portable Station Extension Settings Option 2 Manual C Waiting for Extension Call Feature Manual References 3 1 11 CALL WAITING FEATURES 3 1 12 Call Waiting Tone 4 1 10 DND Do Not Disturb 12 1 3 OHCA Off hook Call Announcement 20 1 4 Whisper OHCA Executive Busy Override ...

Page 387: ...fault Value Range 1 digit 0 9 or Maintenance Console Location 4 11 2 6 3 Numbering Plan B NA DND Call Feature Programming Manual References None Feature Manual References 9 1 13 Intercom Call Message Waiting Set Specifies the feature number used to leave a Message Waiting notification Default 4 Value Range 1 digit 0 9 or Maintenance Console Location 4 11 2 6 3 Numbering Plan B NA DND Call Feature ...

Page 388: ...e and receive callback ringing when the line becomes idle Default 6 Value Range 1 digit 0 9 or Maintenance Console Location 4 11 2 6 3 Numbering Plan B NA DND Call Feature Programming Manual References None Feature Manual References 1 1 4 Automatic Callback Busy Camp on BSS OHCA Whisper OHCA DND Override 2 Specifies the feature number used to notify a busy extension of a second call by Call Waitin...

Page 389: ...n 2 Manual C Waiting for Extension Call 6 10 4 2 1 Portable Station Extension Settings Option 2 Manual C Waiting for Extension Call Feature Manual References 3 1 11 CALL WAITING FEATURES 3 1 12 Call Waiting Tone 4 1 10 DND Do Not Disturb 12 1 3 OHCA Off hook Call Announcement 20 1 4 Whisper OHCA Document Version 2009 12 PC Programming Manual 389 4 11 2 6 3 Numbering Plan B NA DND Call Feature ...

Page 390: ...20 characters Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References None Feature Manual References 3 1 21 COS Class of Service TRS Level Day Lunch Break Night Specifies the Toll Restriction TRS level for making CO line calls in each time mode Default COS No 1 1 COS No 2 2 COS No 3 3 COS No 4 4 COS No 5 5 COS No 6 6 COS No 7 7 COS No 8 64 1 Value Range ...

Page 391: ... Extension Dial Lock feature Default 7 Value Range 1 Allows all CO line calls 2 6 Restricts CO line calls according to the combination of the Denied and Exception Code Tables 7 Restricts all CO line calls Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Set...

Page 392: ...ystem Speed Dialing Feature Manual References 16 1 7 Speed Dialing System 17 1 6 TRS Toll Restriction CO SMDR COS Name Specifies the name of the COS Default Not stored Value Range Max 20 characters Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References None Feature Manual References 3 1 21 COS Class of Service Extension CO Line Call Duration Limit Enabl...

Page 393: ...ure Manual References 3 1 17 CO Line Call Limitation Transfer to CO Enables the transferring of calls to CO lines Default Enable Value Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Manual References 3 1 10 C...

Page 394: ...ccount code is optional or mandatory when making a CO line call Default Option Value Range Option Forced Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Manual References 1 1 2 Account Code Entry Outgoing CO Call Printout SMDR Ena...

Page 395: ... to extension operations can be programmed for each COS COS Name Specifies the name of the COS Default Not stored Value Range Max 20 characters Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References None Feature Manual References 3 1 21 COS Class of Service Executive Busy Override Enables interrupting an existing call to establish a three party conferen...

Page 396: ...on 4 12 2 7 1 Class of Service COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 3 4 1 2 Wired Extension FWD DND 6 10 4 2 1 Portable Station Extension Settings Main COS 6 12 4 2 2 Portable Station FWD DND Feature Manual References 4 1 10 DND Do Not Disturb OHCA Whisper OHCA Enables using OHCA Whisper OHCA as a method of second call notification by e...

Page 397: ...ension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Manual References 3 1 6 Call Monitor Call Pickup by DSS Enables using a DSS button to pick up a call to a specified extension Default Enable Value Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extensi...

Page 398: ...1 COS Class of Service Executive Busy Override Deny Enables preventing other extensions from interrupting calls Default Disable Value Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Manual References 3 1 21 CO...

Page 399: ...COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Manual References 6 1 6 FWD Call Forwarding Programming Mode Level Specifies the level of authorization for performing PT programming Default COS No 1 63 PROG Only COS No 64 PROG Value Range Disable A PT user cannot perform any programming PROG Only A PT user can perform only personal programming PROG A PT user can perform both pe...

Page 400: ...le Value Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 4 6 2 4 Week Table 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Manual References 17 1 5 Time Service PDN SDN An SDN button allows a PT user to see the current status of the corresponding PDN exten...

Page 401: ...nsion is called Standard SDN A dial tone is heard Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References None Feature Manual References 13 1 7 PDN Primary Directory Number SDN Secondary Directory Number Extension Making call by COS of SDN key s owner Selects whether an extension that uses an SDN button to make calls is given the COS of the SDN button s ...

Page 402: ...PT users can create SDN buttons on their own extensions using PT programming Default Enable Value Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References None Feature Manual References 13 1 7 PDN Primary Directory Number SDN Secondary Directory Number Extension Optional Device Other Extensions COS Name Specifies the name of the COS D...

Page 403: ... COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Manual References 4 1 11 Door Open External Relay Access Enables access to external relays Default Enable Value Range Disable Enable Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 7 6 5...

Page 404: ...ge Feature Manual References 4 1 8 DISA Direct Inward System Access Remote Operation by Other Extension Allows the Walking COS feature to be used from a remote location inside the PBX or outside the PBX using DISA Default Allow Value Range Allow Deny Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main...

Page 405: ...nge Allow Deny Maintenance Console Location 4 12 2 7 1 Class of Service COS Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Main COS Feature Manual References 20 1 5 Wireless XDP Parallel Mode Document Version 2009 12 PC Programming Manual 405 4 12 2 7 1 Class of Service COS Settings ...

Page 406: ...unk groups Default All Trunk groups Non Block Value Range Block blue Non Block Maintenance Console Location 4 13 2 7 2 Class of Service External Call Block Programming Manual References 4 6 2 4 Week Table 6 1 4 1 1 Wired Extension Extension Settings 6 10 4 2 1 Portable Station Extension Settings 12 1 10 1 CO Line Settings Feature Manual References 3 1 16 CO Line Access 406 PC Programming Manual Do...

Page 407: ... the combinations of COS levels for which intercom calls are blocked Default All extensions Non Block Value Range Block blue Non Block Maintenance Console Location 4 14 2 7 3 Class of Service Internal Call Block Programming Manual References 5 12 3 5 1 Incoming Call Distribution Group Group Settings Main COS 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extensio...

Page 408: ...g tone pattern for incoming CO line calls Default Single Value Range Single Double Triple Maintenance Console Location 4 15 2 8 1 Ring Tone Patterns Call from CO Programming Manual References 12 1 10 1 CO Line Settings Trunk Group Number 6 1 4 1 1 Wired Extension Extension Settings Option 1 Ring Pattern Table 6 10 4 2 1 Portable Station Extension Settings Option 1 Ring Pattern Table Feature Manual...

Page 409: ...ne pattern for incoming doorphone calls Default Triple Value Range Single Double Triple S Double Maintenance Console Location 4 16 2 8 2 Ring Tone Patterns Call from Doorphone Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 1 Ring Pattern Table 6 10 4 2 1 Portable Station Extension Settings Option 1 Ring Pattern Table 7 1 5 1 Doorphone Feature Manual References 15...

Page 410: ...ation 4 17 2 8 3 Ring Tone Patterns Call from Others Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 1 Ring Pattern Table 6 10 4 2 1 Portable Station Extension Settings Option 1 Ring Pattern Table Feature Manual References None Timed Reminder Ring Tone Pattern Plan 1 8 Specifies the ring tone pattern for Timed Reminder alarms Default Triple Value Range Single Doub...

Page 411: ...n Live Call Screening Ring Tone Pattern Plan 1 8 Specifies the ring tone pattern for LCS warning tones Default Triple Value Range Single Double Triple Maintenance Console Location 4 17 2 8 3 Ring Tone Patterns Call from Others Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 1 Ring Pattern Table 6 10 4 2 1 Portable Station Extension Settings Option 1 Ring Pattern T...

Page 412: ...mming Manual References 6 1 4 1 1 Wired Extension Extension Settings Option 1 Ring Pattern Table 6 10 4 2 1 Portable Station Extension Settings Option 1 Ring Pattern Table Feature Manual References 5 1 9 External Sensor 412 PC Programming Manual Document Version 2009 12 4 17 2 8 3 Ring Tone Patterns Call from Others ...

Page 413: ...ions Programming Manual References None Feature Manual References None PT LCD Time Display Selects the time format shown on the displays of extensions The time display format assigned here applies when setting the Timed Reminder feature Default 12H Value Range 12H 24H Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 17 1 4 Timed Remi...

Page 414: ...DND Fwd LED Selects the light pattern of the FWD DND button while the FWD feature is activated Default Flash Value Range On Solid Red on Flash Slow red flashing Maintenance Console Location 4 18 2 9 System Options Programming Manual References 6 3 4 1 2 Wired Extension FWD DND 6 12 4 2 2 Portable Station FWD DND Feature Manual References 6 1 7 FWD DND Button Group FWD Button 10 1 1 LED Indication ...

Page 415: ...nged Default FWD DND Setting Mode Value Range FWD DND Setting Mode Enter programming mode for the FWD DND setting FWD DND Cycle Switch Switch the FWD on DND on Off mode instead of entering the programming mode for the FWD DND setting When there are separate FWD DND settings for calls from CO lines and calls from extensions mode switching cannot be performed Maintenance Console Location 4 18 2 9 Sy...

Page 416: ...e Value Range Disable The PT user s voice is sent through the handsfree microphone The other party s voice is heard through the hands free speaker Enable The PT user s voice is sent through the handset microphone The other party s voice is heard through both the hands free speaker and the handset Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual...

Page 417: ...ects the speed at which items scroll on the display when the Jog Dial is used Default Normal Value Range Normal High Speed Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References None PT Operation PT Ring Off Setting Specifies whether incoming call ringing can be turned off at individual extensions If disabled users cannot prevent incoming ...

Page 418: ...1 Ring 2 Rings 3 Rings Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 8 1 1 Hands free Answerback PT Operation Automatic Hold by ICM CO ICD Group key Selects whether calls are disconnected or held when an INTERCOM PDN CO or ICD Group button is pressed while having a conversation Default Disconnect Value Range Disable Disconnect Ena...

Page 419: ... Only the holding extension can retrieve a held call Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1 4 Call Hold Option 2 Extension Clear Call Waiting Specifies whether the Call Waiting setting is cleared when Extension Feature Clear is performed Default Clear Value Range Clear Do not clear Maintenance Console Location 4 18 2 9 ...

Page 420: ...eature Manual References 5 1 5 Extension Feature Clear Extension Clear Hot Line Pickup Dial Specifies whether the Hot Line setting is cleared when Extension Feature Clear is performed Default Clear Value Range Clear Do not clear Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 5 1 5 Extension Feature Clear CODEC System CODEC Selects ...

Page 421: ...intenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References None End of Dial Plan as End of Dial for en Bloc mode Specifies whether to automatically send as an end code when dialing to an ISDN line if used as the end code will not be dialed out as part of a number even when the key is pressed Default Enable Value Range Disable Enable Document Ver...

Page 422: ...able Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References 4 5 2 3 Timers Counters Automatic Redial Redial Call Ring Duration Feature Manual References 15 1 1 Redial Last Number Redial Save Dial After Connection to Redial Memory Specifies whether any digits dialed after the called party answers for example to access a specific extension within another company ar...

Page 423: ...imit for extension to CO line calls applies to outgoing calls only or for both outgoing and incoming calls COS determines the use of this feature and the length of the time limit can be assigned on a trunk group basis Default Disable Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References 4 12 2 7 1 Class of Service COS Settings CO SMDR Extensi...

Page 424: ... 1 12 Doorphone Call 3 1 19 Confirmation Tone Confirmation Tone Tone 2 Paged Automatic Answer Enables the PBX to send Confirmation Tone 2 Confirmation Tone 2 is heard from a PT when it receives a call in Hands free Answerback mode or paging Default Enable Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1...

Page 425: ...e Confirmation Tone Tone 3 2 Start Talking after Answering Call Enables the PBX to send Confirmation Tone 3 2 Confirmation Tone 3 2 is heard from an extension when answering a call by for example the Call Pickup feature Default Enable Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1 19 Confirmation Tone...

Page 426: ...Tone 4 2 is heard from an extension when a party leaves a conference call Default Enable Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1 18 Conference 3 1 19 Confirmation Tone Confirmation Tone Tone 5 Hold Enables the PBX to send Confirmation Tone 5 Confirmation Tone 5 is heard from an extension when i...

Page 427: ... the extension Default Enable Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 4 1 4 Dial Tone Dial Tone Dial Tone for Extension Selects the dial tone the PBX sends to extensions to inform about the features activated on them Default Type A Value Range Type A Type B Maintenance Console Location 4 18 2 9 Sys...

Page 428: ...nce Console Location 4 18 2 9 System Options Programming Manual References 3 31 1 1 Slot Port Property PRI Port 10 1 8 1 System Setting Feature Manual References 1 1 3 ARS Automatic Route Selection 4 1 4 Dial Tone Echo Cancel Conference Enables the use of the ECHO card for conference calls Default Enable Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Ma...

Page 429: ...nalog Line Enables the use of the ECHO card for extension to analog CO line calls Default Disable Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References None Echo Cancel Extension to Digital Line Enables the use of the ECHO card for extension to ISDN T1 line calls If set to Enable the echo canceller card is used ...

Page 430: ...r extension or an ICD group Default OFF Value Range ON or Flash OFF Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1 8 Call Pickup 10 1 1 LED Indication DSS Key Call Pick up by DSS key for Direct Incoming Call Specifies whether a DSS button will light up or flash when a call rings at the specified extension To enable this setting...

Page 431: ...ting DSS Key DSS key mode for Incoming Call on this screen must be set to ON or Flash Default Disable Value Range Disable The DSS button will light up when a call arrives but pressing it will not pick up the call Enable The DSS button will flash when a call arrives and pressing it will pick up the call Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature ...

Page 432: ...destination has enabled the call waiting notification feature it is possible to inform the destination about the call transfer Enable The transferred call is queued for the time period specified in Recall Transfer Recall in 4 5 2 3 Timers Counters Maintenance Console Location 4 18 2 9 System Options Programming Manual References 4 5 2 3 Timers Counters Recall Transfer Recall Feature Manual Referen...

Page 433: ...cation 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation Send CLIP of CO Caller to ISDN when ICD Group with Cellular Phone Selects whether the CLIP number of the calling party or of the virtual PS is sent to the virtual PS s forwarding destination to identify the origin of a CO line call received at an ICD Grou...

Page 434: ...ion 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1 3 Caller ID Private Network TIE Call by Extension Numbering Activation Key Required Enables extensions at two PBXs connected in a network not including a VoIP network to have the same leading number For example extension 101 is registered at PBX 1 and extension 102 is registered at PBX 2 Only the Extension...

Page 435: ...ut of Range Timer Feature Manual References 13 1 19 Private Network Features PS Roaming by Network ICD Group System Wireless SDN Delayed Ringing with LCD Selects whether call information such as Caller ID is shown on the display of a PDN extension PS i e a PS with one or more PDN buttons when a call is received while delayed ringing is set Default Disable Value Range Disable Enable Maintenance Con...

Page 436: ...T APT KX T72xx Enables the use of Whisper OHCA to SLTs and IP PTs and DPTs other than KX T7400 series KX T7600 series or KX DT300 series Default Disable Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 20 1 4 Whisper OHCA Call Waiting Automatic Call Waiting for Extension Call Selects whether Busy Station Si...

Page 437: ...ne Call System Feature Access Menu 5 Door Open System Feature Access Menu 6 External BGM System Feature Access Menu 7 Paging System Feature Access Menu 8 Relay On Value Range None Call Back Cancel Call Pickup Direct Call Pickup Group Doorphone Call Door Open Relay On External BGM Paging Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual Reference...

Page 438: ...alue Range 0 60 s Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1 23 CTI Computer Telephony Integration Built in Communication Assistant System status retry counter Specifies the number of times that the alive check is repeated for First Party Call Control CTI such as Communication Assistant CA When the alive check has been atte...

Page 439: ... s Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1 23 CTI Computer Telephony Integration 3rd Party CTI System status retry counter Specifies the number of times that the alive check is repeated for Third Party Call Control CTI When the alive check has been attempted the programmed number of times without success the PBX assumes ...

Page 440: ...sole Location 4 18 2 9 System Options Programming Manual References None Feature Manual References 3 1 23 CTI Computer Telephony Integration 3rd Party CTI CDR retry counter Specifies the number of times that the alive check of CDR is repeated for Third Party Call Control CTI When the alive check has been attempted the programmed number times the association is released automatically Default 1 Valu...

Page 441: ...e Range 1 8 Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References None CTI Make Call SLT Ring Specifies whether to ring an SLT when a call is made from CTI instead of the SLT Default Enable Value Range Disable Enable Maintenance Console Location 4 18 2 9 System Options Programming Manual References None Feature Manual References None Docu...

Page 442: ...g Manual References None Feature Manual References 3 1 3 Caller ID Channel Seizure Signal Bits Specifies the number of seizure bits to send when sending Caller ID information to an SLT Default 300 bits Value Range 10 n n 3 40 bits Maintenance Console Location 4 19 2 10 Extension CID Settings Programming Manual References None Feature Manual References 3 1 3 Caller ID Mark Signal Bits Specifies the...

Page 443: ...nal following the first ring when sending Caller ID information to an SLT Default 512 ms Value Range 64 n n 5 35 ms Maintenance Console Location 4 19 2 10 Extension CID Settings Programming Manual References None Feature Manual References 3 1 3 Caller ID Caller ID Signal Type Specifies the type of signal modulation to be used when sending Caller ID information to an SLT reference only Default FSK ...

Page 444: ... an SLT Default Enable Value Range Disable Enable Maintenance Console Location 4 19 2 10 Extension CID Settings Programming Manual References None Feature Manual References 3 1 3 Caller ID Send Caller ID Date Time to Extension Enables the PBX to send the date and time of an incoming call when sending Caller ID information to an SLT Default Enable Value Range Disable Enable Maintenance Console Loca...

Page 445: ...1 3 Caller ID Send Caller ID Long Distance to Extension Enables the PBX to send a call qualifier Long Distance if received from the CO line when sending Caller ID information to an SLT Default Enable Value Range Disable Enable Maintenance Console Location 4 19 2 10 Extension CID Settings Programming Manual References None Feature Manual References 3 1 3 Caller ID FSK Transmission Level Specifies t...

Page 446: ... dB 6 dB 4 dB 2 dB 0 dB Maintenance Console Location 4 19 2 10 Extension CID Settings Programming Manual References None Feature Manual References 3 1 3 Caller ID 446 PC Programming Manual Document Version 2009 12 4 19 2 10 Extension CID Settings ...

Page 447: ...g Group Feature Manual References 13 1 1 Paging Paging Paging Level from PT Speaker Specifies the volume when paging is broadcast through the speaker of a PT Default 0 dB Value Range 15dB 12dB 9dB 6dB 3dB 0dB 3dB 6dB Maintenance Console Location 4 20 2 11 1 Audio Gain Paging MOH Programming Manual References 5 9 3 4 Paging Group Feature Manual References 13 1 1 Paging MOH MOH Music On Hold Specifi...

Page 448: ...e Location 4 20 2 11 1 Audio Gain Paging MOH Programming Manual References 4 4 2 2 Operator BGM Feature Manual References 11 1 4 Music on Hold 2 1 1 BGM Background Music 448 PC Programming Manual Document Version 2009 12 4 20 2 11 1 Audio Gain Paging MOH ...

Page 449: ...ation 4 21 2 11 2 Audio Gain Card Programming Manual References None Feature Manual References None Down Gain From PBX Specifies the volume for audio signals from the PBX to the selected type of card Default Depends on card type Value Range 15 15 dB Maintenance Console Location 4 21 2 11 2 Audio Gain Card Programming Manual References None Feature Manual References None Document Version 2009 12 PC...

Page 450: ...450 PC Programming Manual Document Version 2009 12 4 21 2 11 2 Audio Gain Card ...

Page 451: ...Section 5 3 Group Document Version 2009 12 PC Programming Manual 451 ...

Page 452: ...G Settings Programming Manual References 12 1 10 1 CO Line Settings Feature Manual References None COS Specifies the COS of the trunk group applied when making a call from a CO line to another CO line with TIE Line Service If you wish to prevent such calls from being made ensure that the COS specified here has a TRS level of 7 assigned for all relevant time modes in 4 12 2 7 1 Class of Service COS...

Page 453: ... CO Line Settings Feature Manual References 3 1 16 CO Line Access CO CO Duration Time 60s Specifies the length of time that a CO to CO line call can be maintained before being disconnected Default 10 Value Range None 60 n n 1 60 s Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings Programming Manual References 12 1 10 1 CO Line Settings Feature Manual References 3 1 17 CO Line Call Li...

Page 454: ...on Table Specifies the table to be used for modifying caller information telephone number Default 1 Value Range 1 4 Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings Programming Manual References 5 3 3 1 3 Caller ID Modification 12 1 10 1 CO Line Settings Feature Manual References 3 1 3 Caller ID Tone Detection Group Name Specifies the name of the trunk group for programming referenc...

Page 455: ...Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings Programming Manual References 7 3 5 3 1 Voice Message DISA System 12 1 10 1 CO Line Settings Feature Manual References 4 1 8 DISA Direct Inward System Access DISA Tone Detection Continuous Enables the disconnection of a DISA originated CO to CO line call by continuous signal detection Default Enable Value Range Disable Enable Maintena...

Page 456: ...s Programming Manual References 7 3 5 3 1 Voice Message DISA System 12 1 10 1 CO Line Settings Feature Manual References 4 1 8 DISA Direct Inward System Access Simplified Voice Message Tone Detection Silence Enables the disconnection of an SVM originated CO to CO line call by silence detection Default Enable Value Range Disable Enable Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings...

Page 457: ...sage Simplified Voice Message Tone Detection Cyclic Enables the disconnection of an SVM originated CO to CO line call by cyclic signal detection Default Enable Value Range Disable Enable Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings Programming Manual References None Feature Manual References 16 1 8 SVM Simplified Voice Message Host PBX Access Code Group Name Specifies the name o...

Page 458: ... number used to access a CO line from the host PBX Default Not stored Value Range Max 10 digits consisting of 0 9 and Maintenance Console Location 5 1 3 1 1 Trunk Group TRG Settings Programming Manual References 12 1 10 1 CO Line Settings Feature Manual References 8 1 5 Host PBX Access Code Access Code to the Telephone Company from a Host PBX 458 PC Programming Manual Document Version 2009 12 5 1 ...

Page 459: ... the trunk group assigned to the corresponding priority level Select the blank option to not assign a trunk group to the priority Default Priority 1 64 Trunk Group No 1 64 Value Range Trunk Group No 1 64 Maintenance Console Location 5 2 3 1 2 Trunk Group Local Access Priority Programming Manual References 12 1 10 1 CO Line Settings Feature Manual References 3 1 16 CO Line Access Document Version 2...

Page 460: ...es each containing 10 local international call data and 1 long distance code can be programmed Each trunk group can select a table for use Select the desired table from the Modification Table list If the modified number does not contain an area code programmed here the PBX applies the Long Distance Code settings to the modified number Area Code for Local International Call Data 1 10 Specifies the ...

Page 461: ...certain number of digits to the caller s number depending on the length of digits as programmed in the Length of Digits Modification Tables assigned to the trunk group This modification is applied to incoming CO line calls routed through public networks when the type of network numbering plan is Unknown or not specified A maximum of 4 Length of Digits Modification Tables can be programmed Select t...

Page 462: ...alue specified here must be smaller than Minimum Caller ID Digits for International Default 8 Value Range 0 30 Maintenance Console Location 5 3 3 1 3 Caller ID Modification Programming Manual References 3 31 1 1 Slot Port Property PRI Port Calling Party Number Type of Number Public Private 3 31 1 1 Slot Port Property PRI Port Called Party Number Type of Number Public Private Feature Manual Referen...

Page 463: ...e Location 5 3 3 1 3 Caller ID Modification Programming Manual References 3 31 1 1 Slot Port Property PRI Port Calling Party Number Type of Number Public Private 3 31 1 1 Slot Port Property PRI Port Called Party Number Type of Number Public Private Feature Manual References 3 1 3 Caller ID CLIP When incoming caller information is sent through an ISDN line and the type of the network numbering plan...

Page 464: ...ure Manual References 3 1 3 Caller ID Added Number Specifies the number to be added to the incoming caller s number in the place of the removed digits for each type of network numbering plan Default International 011 National 1 Subscriber Not stored Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 5 3 3 1 3 Caller ID Modification Programming Manual References 3 31 1 1 Sl...

Page 465: ...t To assign a set of leading numbers automatically click Auto Assign Leading Number Specifies the leading number to be regarded as the beginning of dialing Default No 1 in Dialing Plan Table 1 N11 No 2 in Dialing Plan Table 1 NXX NXX XXXX No 3 in Dialing Plan Table 1 1NXX NXX XXXX Others Not stored Value Range Max 32 digits consisting of 0 9 N 2 3 4 5 6 7 8 9 P 0 1 and X 0 9 and Maintenance Consol...

Page 466: ...umber dialed by en bloc dialing in the place of the removed digits Default Not stored Value Range Max 32 digits consisting of 0 9 Maintenance Console Location 5 4 3 1 4 Dialing Plan Programming Manual References None Feature Manual References 9 1 16 ISDN INTEGRATED SERVICES DIGITAL NETWORK FEATURES 466 PC Programming Manual Document Version 2009 12 5 4 3 1 4 Dialing Plan ...

Page 467: ...ult Type A Value Range Type A 1 N11 2 NXX XXXX 3 1NXX NXX XXXX 4 50 Not stored Type B 1 N11 2 NNX XXXX 3 1NPX NXX XXXX 4 50 Not stored Type C 1 N11 2 NXX XXXX 3 1NNX XXXX 4 1NPX NXX XXXX 5 50 Not stored Type D 1 47 Not stored 48 N11 49 NXX XXXX 50 1NXX NXX XXXX Type E 1 N11 2 NXX NXX XXXX 3 1NXX NXX XXXX 4 50 Not stored Maintenance Console Location 5 5 3 1 4 Dialing Plan Auto Assign Programming Ma...

Page 468: ...tenance Console Location 5 6 3 2 Extension Group Programming Manual References 5 7 3 3 Call Pickup Group 5 9 3 4 Paging Group 6 1 4 1 1 Wired Extension Extension Settings Main Extension Group 6 10 4 2 1 Portable Station Extension Settings Main Extension Group Feature Manual References 7 1 1 GROUP FEATURES Tenant Number Specifies the tenant to which the extension user group belongs Default 1 Value ...

Page 469: ...Feature Manual References 7 1 1 GROUP FEATURES 17 1 3 Tenant Service Document Version 2009 12 PC Programming Manual 469 5 6 3 2 Extension Group ...

Page 470: ...References 6 1 4 1 1 Wired Extension Extension Settings 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 3 1 8 Call Pickup 7 1 1 GROUP FEATURES Pickup Group 1st 8th Selects the call pickup groups that the extension user group belongs to One extension user group can be assigned to a maximum of 8 call pickup groups on this screen To assign an extension user group to more than...

Page 471: ...Feature Manual References 3 1 8 Call Pickup 7 1 1 GROUP FEATURES Document Version 2009 12 PC Programming Manual 471 5 7 3 3 Call Pickup Group ...

Page 472: ... Settings 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 3 1 8 Call Pickup 7 1 1 GROUP FEATURES Extension Group 1 32 Specifies whether the extension user group belongs to the corresponding pickup group Default ON for the same numbered call pickup group Value Range ON blue OFF Maintenance Console Location 5 8 3 3 Call Pickup Group All Setting Programming Manual References ...

Page 473: ...s Maintenance Console Location 5 9 3 4 Paging Group Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 13 1 1 Paging 7 1 1 GROUP FEATURES Paging Group 1st 8th Selects the paging groups that the extension user group belongs to One extension user group can be assigned to a maximum of 8 paging groups on t...

Page 474: ...Feature Manual References 13 1 1 Paging 7 1 1 GROUP FEATURES 474 PC Programming Manual Document Version 2009 12 5 9 3 4 Paging Group ...

Page 475: ...nsion Settings 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 13 1 1 Paging 7 1 1 GROUP FEATURES Extension Group 1 32 Specifies whether the extension user group belongs to the corresponding paging group Default ON for same numbered paging group Value Range ON blue OFF white Maintenance Console Location 5 10 3 4 Paging Group All Setting Programming Manual References 6 1 4 ...

Page 476: ...ension Settings 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 13 1 1 Paging 7 1 1 GROUP FEATURES External Pager 1 Specifies whether the external pager belongs to the corresponding paging group Default ON Value Range ON blue OFF Maintenance Console Location 5 11 3 4 Paging Group External Pager Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings 6 10...

Page 477: ...intenance Console Location 5 11 3 4 Paging Group External Pager Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 13 1 1 Paging 7 1 1 GROUP FEATURES Document Version 2009 12 PC Programming Manual 477 5 11 3 4 Paging Group External Pager ...

Page 478: ...ee 9 1 1 ICD GROUP FEATURES in the Feature Manual Main Floating Extension Number Specifies the floating extension number of the incoming call distribution group Default Groups 001 064 601 664 Groups 065 128 Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual R...

Page 479: ...Feature Manual References 9 1 2 ICD Group Features Group Call Distribution Call Waiting Distribution Selects the call waiting distribution method for busy extensions of the incoming call distribution group Default Distribution Value Range All Distribution Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual Refere...

Page 480: ...ll is received at the incoming call distribution group Default No Ring Value Range No Ring Ring Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References 6 3 4 1 2 Wired Extension FWD DND 6 12 4 2 2 Portable Station FWD DND Feature Manual References 9 1 2 ICD Group Features Group Call Distribution Tenant Number Specifies the tenant to whi...

Page 481: ... or overflowed to a CO line the TRS assigned for the COS of the incoming call distribution group applies Default 1 Value Range 1 64 Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References 4 12 2 7 1 Class of Service COS Settings 4 13 2 7 2 Class of Service External Call Block 4 14 2 7 3 Class of Service Internal Call Block Feature Manua...

Page 482: ...of the incoming call distribution group Default Groups 001 064 601 664 Groups 065 128 Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References None Group Name Specifies the name of the incoming call distribution group Default ICD Group 001 ICD Group 128 ...

Page 483: ... P Pause Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References 4 6 2 4 Week Table Feature Manual References 9 1 5 ICD Group Features Overflow Queuing Busy Queue Call Capacity Specifies the number of calls that can wait in a queue Default 30 Value Range None 1 30 Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group ...

Page 484: ...3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References None Group Name Specifies the name of the incoming call distribution group Default ICD Group 001 ICD Group 128 Value Range Max 20 characters Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual Refere...

Page 485: ...5 ICD Group Features Overflow Time out Manual Queue Redirection Overflow Time Specifies the length of time calls wait in a queue before they are redirected to the overflow destination Default None Value Range None 10 n n 1 125 s Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References 9 1 6 ICD Group Featur...

Page 486: ...ecifies the floating extension number of the incoming call distribution group Default Groups 001 064 601 664 Groups 065 128 Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References None Group Name Specifies the name of the incoming call distribution grou...

Page 487: ...tion Group Group Settings Programming Manual References 4 6 2 4 Week Table Feature Manual References 9 1 6 ICD Group Features Queuing Queuing Time Table When Extension Ringing Enables the PBX to play messages BGM to the caller according to the Queuing Time Table when the call arrives at an extension without being queued or after being queued Default Enable Value Range Disable Ringback Tone Enable ...

Page 488: ...le Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References None Group Name Specifies the name of the incoming call distribution group Default ICD Group 001 ICD Group 128 Value Range Max 20 characters Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None 488 ...

Page 489: ...ne Feature Manual References 9 1 2 ICD Group Features Group Call Distribution 9 1 6 ICD Group Features Queuing No of Unanswered Calls for Automatic Log out Specifies the number of consecutive unanswered calls before a member extension is automatically logged out from the incoming call distribution group Default None Value Range None 1 15 Maintenance Console Location 5 12 3 5 1 Incoming Call Distri...

Page 490: ...rences 9 1 2 ICD Group Features Group Call Distribution Last Extension Log out Specifies whether the last extension logged in to the incoming call distribution group is allowed to log out Default Enable Value Range Disable Enable Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References 9 1 3 ICD Group Featu...

Page 491: ... supervisor extension need not belong to the group Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References 9 1 7 ICD Group Features Supervisory Programmed Mailbox No Specifies the mailbox number of the incoming call distribution group s mailbox ...

Page 492: ...on group Default Groups 001 064 601 664 Groups 065 128 Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References None Group Name Specifies the name of the incoming call distribution group Default ICD Group 001 ICD Group 128 Value Range Max 20 characters M...

Page 493: ...oup Settings Programming Manual References None Feature Manual References 3 1 5 Call Log Incoming Group FWD Call from CO Setting Indicates the current FWD status for incoming CO line calls reference only Default Off Value Range Off On Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References 6 1 6 FWD Call F...

Page 494: ...Setting Indicates the current FWD status for incoming intercom calls reference only Default Off Value Range Off On Maintenance Console Location 5 12 3 5 1 Incoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References 6 1 6 FWD Call Forwarding Group FWD Call from Extension Destination Specifies the forward destination of incoming intercom calls directe...

Page 495: ...ncoming Call Distribution Group Group Settings Programming Manual References None Feature Manual References 6 1 6 FWD Call Forwarding Document Version 2009 12 PC Programming Manual 495 5 12 3 5 1 Incoming Call Distribution Group Group Settings ...

Page 496: ...tension Number Setting To copy the members to another group click Member list copy select the group and click OK Extension Number Specifies the extension number of each member In addition to the extension numbers of PT SLT PS and T1 OPX extensions floating extension numbers of PS Ring groups can also be specified Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Loc...

Page 497: ... 5 1 Incoming Call Distribution Group Group Settings Main Distribution Method Feature Manual References 9 1 2 ICD Group Features Group Call Distribution Wrap up Timer Specifies the length of time that must pass after completing a call before the member extension can accept another call This timer is used when Options Wrap up Timer based on is set to ICD Group Member in 5 15 3 5 3 Incoming Call Dis...

Page 498: ...Timer 6 10 4 2 1 Portable Station Extension Settings Option 8 Wrap up Timer Feature Manual References 9 1 3 ICD Group Features Log in Log out 498 PC Programming Manual Document Version 2009 12 5 13 3 5 1 Incoming Call Distribution Group Group Settings Member List ...

Page 499: ...nnect Disconnects the line Sequence 01 16 Redirects the call to a different sequence Wait 5 n n 1 16 s If preceded by an OGM plays the Music on Hold for the specified period of time if not preceded by an OGM sends a ringback tone for the specified period of time OGM 01 64 Sends a certain OGM Maintenance Console Location 5 14 3 5 2 Incoming Call Distribution Group Queuing Time Table Programming Man...

Page 500: ...OUP FEATURES Options ICD Group Key Mode Selects whether ICD Group buttons at extensions operate as normal or in Enhanced Phantom button mode When set to Enhanced Phantom mode creating an ICD Group button at an extension using PT personal programming automatically registers the extension as a member of the relevant ICD Group The extension user can also specify the delayed ringing settings Default G...

Page 501: ...on Group Group Settings Member List becomes unavailable If ICD Group Member is selected Wrap up Timer on 6 1 4 1 1 Wired Extension Extension Settings and 6 10 4 2 1 Portable Station Extension Settings become unavailable Default Extension Value Range Extension The timer is activated after all calls to or from the extension including a retrieved call on hold ICD Group Member The timer is only activa...

Page 502: ...Feature Manual References 9 1 3 ICD Group Features Log in Log out 502 PC Programming Manual Document Version 2009 12 5 15 3 5 3 Incoming Call Distribution Group Miscellaneous ...

Page 503: ...st To assign extensions as overflow destinations easily click Destination Setting see 2 1 6 Extension Number Setting Hunting Group Name Specifies the name of the hunting group Default Not stored Value Range Max 20 characters Maintenance Console Location 5 16 3 6 Extension Hunting Group Programming Manual References None Feature Manual References 9 1 9 Idle Extension Hunting Hunting Type Specifies ...

Page 504: ... call in each time mode Default Not stored Value Range Max 32 digits consisting of 0 9 T Transfer Secret P Pause and F Flash Maintenance Console Location 5 16 3 6 Extension Hunting Group Programming Manual References None Feature Manual References 9 1 9 Idle Extension Hunting 504 PC Programming Manual Document Version 2009 12 5 16 3 6 Extension Hunting Group ...

Page 505: ...Range Max 5 digits consisting of 0 9 Maintenance Console Location 5 17 3 6 Extension Hunting Group Member List Programming Manual References 5 16 3 6 Extension Hunting Group Feature Manual References 9 1 9 Idle Extension Hunting Extension Name Indicates the name of the extension when an extension number is specified in Extension Number above reference only Default Not stored Value Range Max 20 cha...

Page 506: ...ion Port Feature Manual References 9 1 6 ICD Group Features Queuing 19 1 3 Voice Mail VM Group Intercept to Mailbox Enables the PBX to send the mailbox number of the called extension to the VPS when a call is redirected to the VM DPT group by Intercept Routing When the VPS receives the mailbox number the VPS answers the call with the appropriate mailbox Default Enable Value Range Disable Enable Ma...

Page 507: ...feature using the Automated Attendant AA service of the VPS and the call is not answered within a programmed time period 2 when the VPS is assigned as the Transfer Recall destination of a certain extension When the VPS receives the mailbox number the VPS answers the call with the appropriate mailbox Default Enable Value Range Disable Enable Maintenance Console Location 5 18 3 7 1 VM DPT Group Syst...

Page 508: ...ocation 5 19 3 7 2 VM DPT Group Unit Settings Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Manual References 19 1 3 Voice Mail VM Group 19 1 4 Voice Mail DPT Digital Integration Group Name Specifies the name of the VM DPT group which will be shown on the display of extensions that call the VM DPT group Default VM Unit No x Voicemail x Value Range Max 20 characte...

Page 509: ...19 1 4 Voice Mail DPT Digital Integration Document Version 2009 12 PC Programming Manual 509 5 19 3 7 2 VM DPT Group Unit Settings ...

Page 510: ...t slot number Value Range Slot number Maintenance Console Location 5 20 3 7 2 VM DPT Group Unit Settings Member List Programming Manual References DPT Type Type 5 19 3 7 2 VM DPT Group Unit Settings Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 5 20 3 7 2 VM DPT Group Unit Settings Membe...

Page 511: ... 5 19 3 7 2 VM DPT Group Unit Settings Feature Manual References 19 1 3 Voice Mail VM Group VM Port No Indicates the VM port number for the port reference only Default 1 Value Range 1 12 Maintenance Console Location 5 20 3 7 2 VM DPT Group Unit Settings Member List Programming Manual References DPT Type Type 5 19 3 7 2 VM DPT Group Unit Settings Feature Manual References 19 1 3 Voice Mail VM Group...

Page 512: ...ature Manual References 19 1 3 Voice Mail VM Group 19 1 4 Voice Mail DPT Digital Integration Extension Name Indicates the name of the extension reference only Default Not stored Value Range Max 20 characters Maintenance Console Location 5 20 3 7 2 VM DPT Group Unit Settings Member List Programming Manual References DPT Type Type 5 19 3 7 2 VM DPT Group Unit Settings Feature Manual References 19 1 ...

Page 513: ...gnal the PBX sends to the VPS when the called extension is ringing Default 1 Value Range Max 4 digits consisting of 0 9 and P pause Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Manual References None VM DTMF Status Signal Busy Tone Specifies the DTMF status signal the PBX sends to the VPS when the called extension is busy Default ...

Page 514: ...TMF status signal the PBX sends to the VPS when the called extension is in DND mode Default 4 Value Range Max 4 digits consisting of 0 9 and P pause Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Manual References None VM DTMF Status Signal Answer Specifies the DTMF status signal the PBX sends to the VPS when the called extension ha...

Page 515: ...digits consisting of 0 9 and P pause Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Manual References None VM DTMF Status Signal Disconnect Specifies the DTMF status signal the PBX sends to the VPS when the caller hangs up Default 9 Value Range Max 4 digits consisting of 0 9 and P pause Maintenance Console Location 5 21 3 8 1 VM DTM...

Page 516: ...tem Settings Programming Manual References None Feature Manual References None VM DTMF Status Signal FWD to VM Busy Tone Specifies the DTMF status signal the PBX sends to the VPS when the call has been forwarded to the VPS and all ports of the VPS are busy Default 7 Value Range Max 4 digits consisting of 0 9 and P pause Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programm...

Page 517: ...ll is forwarded intercepted or transferred to the VPS so that the caller can leave a message in a certain mailbox Default H Value Range Max 16 digits consisting of 0 9 H mailbox number and P pause Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Manual References None VM DTMF Command Listening Message Specifies the DTMF command the PB...

Page 518: ...ode to AA Service Mode Default 8 Value Range Max 16 digits consisting of 0 9 H mailbox number and P pause Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Manual References None VM DTMF Command Switching to VM Specifies the DTMF command the PBX sends to the VPS to switch from AA Service Mode to VM Service Mode Default 6 Value Range Ma...

Page 519: ...nance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Manual References None Timing Inter digit Time Specifies the length of pause time between DTMF signals the PBX sends to the VPS Default 80 ms Value Range 80 ms 160 ms Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References None Document Version 2009...

Page 520: ...gramming Manual References None Feature Manual References None Timing Waiting Time before Sending VM DTMF Status Signal Specifies the length of time that the PBX waits before sending the DTMF status signal to the VPS after the VPS has finished dialing Default 1 5 s Value Range 0 5 s 1 0 s 1 5 s 2 0 s Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual Reference...

Page 521: ...n answer the call either with a mailbox or in the AA service mode It is also possible to send no DTMF signal to the VPS Default Answer by Mailbox Value Range None Answer by Mailbox AA Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Manual References 6 1 6 FWD Call Forwarding Others Intercept Routing to the VPS Sequence Specifies whic...

Page 522: ...umber Maintenance Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References 5 12 3 5 1 Incoming Call Distribution Group Group Settings Miscellaneous Programmed Mailbox No 6 1 4 1 1 Wired Extension Extension Settings Option 1 Programmed Mailbox No 6 10 4 2 1 Portable Station Extension Settings Option 1 Programmed Mailbox No Feature Manual References None Others Message...

Page 523: ...ce Console Location 5 21 3 8 1 VM DTMF Group System Settings Programming Manual References None Feature Manual References 11 1 3 Message Waiting Document Version 2009 12 PC Programming Manual 523 5 21 3 8 1 VM DTMF Group System Settings ...

Page 524: ...Max 5 digits consisting of 0 9 Maintenance Console Location 5 22 3 8 2 VM DTMF Group Group Settings Programming Manual References None Feature Manual References 19 1 3 Voice Mail VM Group Group Name Specifies the name of the VM DTMF group which will be shown on the display of extensions that call the VM DTMF group Default Not stored Value Range Max 20 characters Maintenance Console Location 5 22 3...

Page 525: ...t AA Value Range AA VM Maintenance Console Location 5 22 3 8 2 VM DTMF Group Group Settings Programming Manual References None Feature Manual References 19 1 5 Voice Mail DTMF Integration Document Version 2009 12 PC Programming Manual 525 5 22 3 8 2 VM DTMF Group Group Settings ...

Page 526: ...f 0 9 Maintenance Console Location 5 23 3 8 2 VM DTMF Group Group Settings Member List Programming Manual References 3 24 1 1 Slot Port Property Extension Port Extension Number 5 22 3 8 2 VM DTMF Group Group Settings Feature Manual References 19 1 5 Voice Mail DTMF Integration Extension Name Indicates the name of the extension reference only Default Not stored Value Range Max 20 characters Mainten...

Page 527: ...Feature Manual References 19 1 5 Voice Mail DTMF Integration Document Version 2009 12 PC Programming Manual 527 5 23 3 8 2 VM DTMF Group Group Settings Member List ...

Page 528: ...e Range Max 5 digits consisting of 0 9 Maintenance Console Location 5 24 3 9 PS Ring Group Programming Manual References None Feature Manual References 13 1 29 PS Ring Group Group Name Specifies the name of the PS ring group which will be shown on the display of extensions that call the PS ring group when Incoming Trunk Call Information Display on this screen is set to Called Number Default Not st...

Page 529: ...roup If the caller s name or called party s name is not recognized the telephone number will be shown Default Caller ID Value Range Caller ID Called Number Maintenance Console Location 5 24 3 9 PS Ring Group Programming Manual References None Feature Manual References 13 1 29 PS Ring Group Document Version 2009 12 PC Programming Manual 529 5 24 3 9 PS Ring Group ...

Page 530: ...o the PS Ring Group Default Not stored Value Range Max 5 digits Maintenance Console Location 5 25 3 9 PS Ring Group Member List Programming Manual References 5 24 3 9 PS Ring Group 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 13 1 29 PS Ring Group Extension Name Indicates the name of the PS reference only Default Not stored Value Range Max 20 characters Maintenance Cons...

Page 531: ...Feature Manual References 13 1 29 PS Ring Group Document Version 2009 12 PC Programming Manual 531 5 25 3 9 PS Ring Group Member List ...

Page 532: ...chronization Group Programming Manual References 13 6 11 5 Air Synchronization Feature Manual References None Group Name Specifies a name for the Air Synchronization Group Default Not stored Value Range Max 20 characters Maintenance Console Location 5 26 3 10 Air Synchronization Group Programming Manual References 13 6 11 5 Air Synchronization Feature Manual References None 532 PC Programming Manu...

Page 533: ...Section 6 4 Extension Document Version 2009 12 PC Programming Manual 533 ...

Page 534: ...lexible button settings To assign a set of CLIP numbers automatically click CLIP Generate Main Shelf Indicates the shelf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Slot Indicates the slot position of each extension card referen...

Page 535: ... References None Extension Number Specifies the extension number of the extension Default Starting at 101 Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Name Specifies the name of the extension Doc...

Page 536: ... port DHLC S Hybrid S DPT Digital XDP port of Super Hybrid port DHLC DPT S DPT Digital XDP port of DPT port DLC ISDN ISDN port PRI OPX T1 OPX port T1 IP EXT Virtual IP Extension port V IPEXT SIP Virtual SIP Extension port V SIPEXT Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References 5 1 7 Extension Port Configuration...

Page 537: ...IPEXT card is connected SIP SIP Extension is connected Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Extension Group Specifies the extension user group to which the extension belongs Extension user groups are used to compose tenants call pickup groups and paging groups Default For Extensions connected wit...

Page 538: ... be made if a third party discovers a personal identification number PIN verification code PIN or extension PIN of the PBX The cost of such calls will be billed to the owner renter of the PBX To protect the PBX from this kind of fraudulent use we strongly recommend a Keeping PINs secret b Selecting complex random PINs that cannot be easily guessed c Changing PINs frequently Default Not stored Valu...

Page 539: ...gs Programming Manual References None Feature Manual References None Slot Indicates the slot position of each extension card reference only Default Current slot number Value Range Slot number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Port Indicates the port number reference only Document Version 2009 ...

Page 540: ...tarting at 101 Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Name Specifies the name of the extension Value Range Max 20 characters Maintenance Console Location 6 1 4 1 1 Wired Extension Extension...

Page 541: ... 1 1 Wired Extension Extension Settings Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Intercept Destination Intercept Destination When Called Party is Busy Feature Manual References 9 1 11 Intercept Routing Intercept Destination When Called Party is Busy Specifies the Intercept Routing destination of calls when the extension is busy Value Range Max 32 digits consisting...

Page 542: ...l References None Slot Indicates the slot position of each extension card reference only Default Current slot number Value Range Slot number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number 542 PC Programming Manual Document Version 20...

Page 543: ...nge Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Name Specifies the name of the extension Default Not stored Value Range Max 20 characters Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Set...

Page 544: ...ion 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 4 5 2 3 Timers Counters Dial IRNA Recall Tone Intercept Routing No Answer IRNA Day Lunch Break Night Feature Manual References 9 1 11 Intercept Routing ISDN CLIP Shelf Indicates the shelf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console Location 6 1 4 1 1 Wired Extension Ex...

Page 545: ...eature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension Document Version 2009 12 PC P...

Page 546: ... the extension Default Not stored Value Range Max 20 characters Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None CLIP ID Specifies the CLIP number sent to the public network to show on the called party s telephone display when making a CO line call Default Not stored Value Range Max 16 digits consisting of 0...

Page 547: ...ort Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 31 1 1 Slot Port Property PRI Port CO Setting Subscriber Number 6 1 4 1 1 Wired Extension Extension Settings ISDN CLIP CLIP ID Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation CLIR Specifies whether to restrict the display of the CLIP number on the called part...

Page 548: ...ntenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation Option 1 Shelf Indicates the shelf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References ...

Page 549: ...ot Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension Document Version 2009 12 ...

Page 550: ...Manual References None Wireless XDP Specifies the extension number of the PS with which Wireless XDP Parallel Mode is established To enable Wireless XDP Parallel Mode the PS must be turned off once and then turned on after assigning this setting This setting is not available when the software is in Batch mode In addition a PS with PDN or SDN buttons cannot be used for Wireless XDP Parallel Mode Wh...

Page 551: ...tension Settings Programming Manual References 4 15 2 8 1 Ring Tone Patterns Call from CO 4 16 2 8 2 Ring Tone Patterns Call from Doorphone 4 17 2 8 3 Ring Tone Patterns Call from Others Feature Manual References 15 1 2 Ring Tone Pattern Selection Programmed Mailbox No Specifies the mailbox number of the extension s mailbox for Voice Processing Systems VPS with DTMF Integration Default Same number...

Page 552: ...e Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References 3 1 10 Call Transfer ARS Itemized Code Specifies the itemized billing code used by the ARS feature for identifying calls made from the extension for accounting and billing purposes Default Not stored Value Range Max 10 digits consis...

Page 553: ...sion Extension Settings Programming Manual References None Feature Manual References None Slot Indicates the slot position of each extension card reference only Default Current slot number Value Range Slot number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 1 1 1 Slot Feature Manual References None Document Version 2009 12 PC Programming...

Page 554: ...ies the extension number of the extension Default Starting at 101 Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Name Specifies the name of the extension Default Not stored Value Range Max 20 chara...

Page 555: ... in speaker W OHCA Voice from the handset Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References 3 1 11 CALL WAITING FEATURES Automatic C Waiting Specifies whether to receive call waiting notifications for calls from a CO line doorphone calls and calls via an incoming call distribution group Default On Value Range Off ...

Page 556: ...ual References 4 5 2 3 Timers Counters Dial IRNA Recall Tone Dial Hot Line Pickup Dial Start Feature Manual References 8 1 6 Hot Line Pickup Dial No Specifies the number to be dialed automatically after going off hook when the Hot Line feature is active Default Not stored Value Range Max 32 digits consisting of 0 9 T Transfer Secret P Pause and F Flash Maintenance Console Location 6 1 4 1 1 Wired ...

Page 557: ...ences 4 1 1 Data Line Security Option 3 Shelf Indicates the shelf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Slot Indicates the slot position of each extension card reference only Default Current slot number Document Version 20...

Page 558: ...tenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension Default Starting at 101 Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings 558 PC Programming M...

Page 559: ...eature Manual References None Call Pickup Deny Specifies whether calls can be picked up by other extensions Default Disable Value Range Disable Allows other extension users to pick up calls to your extension Enable Prevents other extension users from picking up calls to your extension Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Featu...

Page 560: ...pecifies the Personal Absent Message which unlike the System Absent Message can be customized for each extension Default Not stored Value Range Max 16 characters Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References 1 1 1 Absent Message Intercom Call by Voice Selects the method of receiving intercom calls When Deny Vo...

Page 561: ...elf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Slot Indicates the slot position of each extension card reference only Default Current slot number Value Range Slot number Document Version 2009 12 PC Programming Manual 561 6 1 4 ...

Page 562: ...on Settings Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension Default Starting at 101 Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Conne...

Page 563: ...le CO line is seized automatically from the programmed trunk groups ICM PDN An extension line is seized or for a PDN extension an idle PDN button is selected F 1 F 84 A CO line programmed for a flexible button F 1 F 84 is seized A flexible button customized as a Single CO Group CO Loop CO or ICD Group button must be selected Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings...

Page 564: ...button F 1 F 84 is selected A flexible button customized as a Single CO Group CO Loop CO or ICD Group button must be selected Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 6 5 4 1 4 Wired Extension Flexible Button Feature Manual References 10 1 2 Line Preference Incoming Call Waiting Tone Type Selects the type of Call Waiting tone sent to t...

Page 565: ...r Mode Specifies whether the extension s mailbox is monitored in Hands free or Private mode Default Hands free Value Range Hands free Monitor through the built in speaker Private Monitor through the handset or the built in speaker after hearing a warning tone Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References 8 1 2...

Page 566: ...of each extension card reference only Default Current slot number Value Range Slot number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 1 1 1 Slot Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number 566 PC Programming Manual Document Version 2009 12 6 1 4 1 1 Wir...

Page 567: ... 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Name Specifies the name of the extension Default Not stored Value Range Max 20 characters Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual Refer...

Page 568: ... caller information is shown on the first line of the extension s display Default Caller ID Name Value Range Caller ID Name CO Line Name DID Name Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References 4 1 9 Display Information Automatic LCD Switch when Start Talking Enables the first line of the display to show the cal...

Page 569: ...red Extension Extension Settings Programming Manual References None Feature Manual References None Automatic Answer for CO Call Enables the extension to answer an incoming CO line call automatically after a certain number of rings without going off hook when Hands free Answerback has been set on the extension This setting is only effective when Forced Automatic Answer on this screen has been set t...

Page 570: ...Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Slot Indicates the slot position of each extension card reference only Default Current slot number Value Range Slot number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 1 1 1 Slot 570 PC Programming M...

Page 571: ... References None Extension Number Specifies the extension number of the extension Default Starting at 101 Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Name Specifies the name of the extension Doc...

Page 572: ...alue Range Off On Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Flexible Button Programming Mode Specifies whether the extension user can modify all flexible buttons without limitation or only the One touch Dialing buttons When the mode is set to One touch Dial there is no need to enter 2 before the numbe...

Page 573: ... 30 is selected ring tone 1 is heard Other telephones 1 8 Even if ring tone 9 30 is selected ring tone 2 is heard Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Display Lock SVM Lock Locks or unlocks the Incoming Call Log and Simplified Voice Message Log display i e specifies whether other extension users ...

Page 574: ...nance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References 13 1 1 Paging Option 7 Shelf Indicates the shelf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None 574 PC Programming Manual Document Ve...

Page 575: ...ot Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 24 1 1 Slot Port Property Extension Port Feature Manual References None Extension Number Specifies the extension number of the extension Document Version 2009 12 ...

Page 576: ...me Specifies the name of the extension Default Not stored Value Range Max 20 characters Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Character Input Mode Selects the character table to be used for entering characters Default Table 1 Value Range Table 1 Standard mode Table 2 Option mode 576 PC Programming...

Page 577: ... 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References 5 1 1 EFA External Feature Access 6 1 2 Flash Recall Terminate Incoming Call Log Memory Specifies the number of incoming CO line calls that are retained in the extension s Incoming Call Log memory Default 10 Value Range 0 100 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Sett...

Page 578: ...References 15 1 1 Redial Last Number ISDN Bearer Selects the ISDN bearer mode When Automatic is selected the bearer mode is set automatically depending on the extension s telephone type as follows PT Speech SLT Audio Default Automatic Value Range Automatic Speech Audio Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual Refere...

Page 579: ...nces None Slot Indicates the slot position of each extension card reference only Default Current slot number Value Range Slot number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Document Version 2009 12 PC Programming Manual 579 6 ...

Page 580: ...nge Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Name Specifies the name of the extension Default Not stored Value Range Max 20 characters Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Set...

Page 581: ...le Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Extension Caller ID Enables the extension to send Caller ID information to an SLT Default Enable Value Range Disable Enable Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual Reference...

Page 582: ...erences 3 1 3 Caller ID Wrap up Timer Specifies the length of time that must pass after completing a call before an extension will accept another call when logged in as a member of an Incoming Call Distribution Group This timer is used when Options Wrap up Timer based on is set to Extension in 5 15 3 5 3 Incoming Call Distribution Group Miscellaneous Default 0 s Value Range 0 3000 s Maintenance Co...

Page 583: ...nces None Slot Indicates the slot position of each extension card reference only Default Current slot number Value Range Slot number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Document Version 2009 12 PC Programming Manual 583 6 ...

Page 584: ...nge Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Name Specifies the name of the extension Default Not stored Value Range Max 20 characters Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Set...

Page 585: ...SDN Secondary Directory Number Extension Built in Communication Assistant Specifies whether to enable or disable the Communication Assistant CA application for each extension This setting is not available when the corresponding extension is a SIP extension Default Enable Value Range Disable Basic Only Enable Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manu...

Page 586: ...tion 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References None Feature Manual References None Slot Indicates the slot position of each extension card reference only Default Current slot number Value Range Slot number Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 1 1 1 Slot Feature Manual References None Port Indicate...

Page 587: ...r of the extension Default Starting at 101 Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 3 25 1 1 Slot Port Property Extension Port Connection Command Feature Manual References None Extension Name Specifies the name of the extension Default Not stored Value Range Max 20 characters Document Version ...

Page 588: ...red Extension Extension Settings Programming Manual References 6 3 4 1 2 Wired Extension FWD DND Feature Manual References 6 1 6 FWD Call Forwarding DND Set for Call from CO Indicates the current DND status for incoming CO line calls reference only Default Off Value Range Off On Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 6 3 4 1 2 Wired ...

Page 589: ...Forwarding FWD Destination for Call from CO Indicates the forwarding destination of incoming CO line calls reference only Default Not stored Value Range Max 32 digits consisting of 0 9 Secret and P Pause Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 6 3 4 1 2 Wired Extension FWD DND Feature Manual References 6 1 6 FWD Call Forwarding FWD Se...

Page 590: ...calls reference only Default Off Value Range Off On Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 6 3 4 1 2 Wired Extension FWD DND Feature Manual References 4 1 10 DND Do Not Disturb FWD Mode for Call from Extension Indicates the forwarding type of incoming intercom calls reference only Default None Value Range None FWD All FWD Busy FWD N ...

Page 591: ...Maintenance Console Location 6 1 4 1 1 Wired Extension Extension Settings Programming Manual References 6 3 4 1 2 Wired Extension FWD DND Feature Manual References 6 1 6 FWD Call Forwarding FWD No Answer Time Indicates the length of time that an incoming call rings at the extension before the call is forwarded reference only Default 15 s Value Range 0 120 s Maintenance Console Location 6 1 4 1 1 W...

Page 592: ...Feature Manual References 6 1 6 FWD Call Forwarding 592 PC Programming Manual Document Version 2009 12 6 1 4 1 1 Wired Extension Extension Settings ...

Page 593: ... Extension Extension Settings CLIP Generate Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation Location Entry Number to Generate Specifies the number of locations to be programmed A CLIP number will only be assigned to connected wired extensions even if the number entered here is larger than the ...

Page 594: ...15 CLIP Calling Line Identification Presentation Parameter Head of ID Specifies a prefix number to be applied to all generated CLIP numbers Default Not stored Value Range Max 16 digits consisting of 0 9 and Maintenance Console Location 6 2 4 1 1 Wired Extension Extension Settings CLIP Generate Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Feature Manual References 3 1 ...

Page 595: ...red Extension Extension Settings CLIP Generate Programming Manual References 6 1 4 1 1 Wired Extension Extension Settings Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation Document Version 2009 12 PC Programming Manual 595 6 2 4 1 1 Wired Extension Extension Settings CLIP Generate ...

Page 596: ...f Maintenance Console Location 6 3 4 1 2 Wired Extension FWD DND Programming Manual References None Feature Manual References 4 1 10 DND Do Not Disturb 6 1 6 FWD Call Forwarding Forward DND For internal calls Specifies the FWD DND setting for internal calls If Always All Busy No Answer or Busy No Answer is selected the FWD destination field can be set If For both external calls and internal calls ...

Page 597: ... an incoming call rings at the extension before the call is forwarded Default 15 s Value Range 0 120 s Maintenance Console Location 6 3 4 1 2 Wired Extension FWD DND Programming Manual References None Feature Manual References 6 1 6 FWD Call Forwarding Document Version 2009 12 PC Programming Manual 597 6 3 4 1 2 Wired Extension FWD DND ...

Page 598: ...ll using the Personal Speed Dialing Directory shown on the extension s display Default Not stored Value Range Max 20 characters Maintenance Console Location 6 4 4 1 3 Wired Extension Speed Dial Programming Manual References None Feature Manual References 16 1 6 Speed Dialing Personal Dialing Number Specifies the number to be dialed by the Personal Speed Dialing number Default Not stored Value Rang...

Page 599: ...ible buttons see 6 1 3 Flexible Buttons in the Feature Manual Display Option Key Setting Type Specifies the feature to be assigned to the flexible button Default Single CO Value Range Not Stored Loop CO Single CO Group CO DSS One touch G DN Message Waiting FWD DND Both FWD DND External FWD DND Internal Group Fwd Both Group Fwd External Group Fwd Internal Account Conference Terminate EFA Call Park ...

Page 600: ...red Extension Flexible Button Programming Manual References None Feature Manual References 3 1 16 CO Line Access Parameter Selection for Call Park Specifies whether a call is parked in an idle parking zone automatically or in a specific parking zone Default Automatic Value Range Automatic Specific Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References ...

Page 601: ...ribution group Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References 9 1 3 ICD Group Features Log in Log out Parameter Selection for Time Service Selects which time modes are switched manually Default All Value Range All Day Night Lunch Break Day Night Break Day Night Lunch Day Night Maintenance Console Location 6 5 4 1 ...

Page 602: ...er Selection for Time Service Automatic Manual Specifies the Time Table to be used when the Time Service Switching Mode is set to Automatic Default 1 Value Range 1 8 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References 17 1 5 Time Service Parameter Selection for SDN Specifies the delayed ringing setting for calls arrivi...

Page 603: ... accessed Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References None Ext No Floating Ext No for G DN Specifies the floating extension number of an incoming call distribution group to be accessed Default Not stored Value Range Max 5 digits consisting of 0 9 Mai...

Page 604: ...cation 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References None Ext No Floating Ext No for Group Fwd Both Specifies the floating extension number of an incoming call distribution group for which both intercom and CO line calls are forwarded Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 5 4 1 4 Wired E...

Page 605: ...mber of an incoming call distribution group for which intercom calls are forwarded Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References 6 1 6 FWD Call Forwarding Ext No Floating Ext No for Call Log Specifies the extension s own number or the floating extensio...

Page 606: ...stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References 9 1 3 ICD Group Features Log in Log out Ext No Floating Ext No for Hurry up Specifies the floating extension number of the incoming call distribution group whose longest waiting call will be redirected Manual Queue Red...

Page 607: ...intenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References 19 1 4 Voice Mail DPT Digital Integration Ext No Floating Ext No for Two way Transfer Specifies the floating extension number of the VM DPT group containing the desired mailbox Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 ...

Page 608: ...ion 19 1 4 Voice Mail DPT Digital Integration Ext No Floating Ext No for SDN Specifies the floating extension number of the PDN extension corresponding to this SDN button Note that the extension specified here must have a PDN button registered for the SDN button to function Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible...

Page 609: ...Note that only extension numbers that have been previously registered in 11 4 9 4 NDSS Key Table can be specified here Default Not stored Value Range Max 16 digits consisting of 0 9 T Transfer Secret P Pause and F Flash Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References 13 1 17 Private Network Features NDSS Network Di...

Page 610: ...omatic Switching mode Default 1 Value Range 1 8 Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References 17 1 5 Time Service Optional Parameter Ringing Tone Type Number for Loop CO Single CO Group CO G DN SDN Specifies the ring tone type Default 1 Value Range KX DT300 series except KX DT321 KX T7600 series IP PT except NT26...

Page 611: ...le Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References 3 1 7 Call Park Ext No of Mailbox for Two way Transfer Specifies the number of the extension whose mailbox will be used to record conversations using One touch Two way Transfer For example a secretary can record a conversation into the mailbox of a boss If the cell is left empty the e...

Page 612: ... None Extension Number This parameter is equivalent to Ext No Floating Ext No on the Key Setting screen Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References 6 5 4 1 4 Wired Extension Flexible Button Display Option Key Setting Ext No Floating Ext No for DSS Ext No Floating Ext No for G DN Ext No Floating Ext No for Message Waiting Ext No Floating Ext ...

Page 613: ...ion 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References 6 5 4 1 4 Wired Extension Flexible Button Display Option Key Setting Parameter Selection for Single CO Parameter Selection for Group CO Parameter Selection for Call Park Parameter Selection for Log in Log out Parameter Selection for Time Service Parameter Selection for TRS Level Change Parameter Selection for Time Service ...

Page 614: ...t to Ext No of Mailbox on the Key Setting screen Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References 6 5 4 1 4 Wired Extension Flexible Button Display Option Key Setting Ext No of Mailbox for Two way Transfer Feature Manual References None Label Specifies the label that will be printed next to the corresponding button Default Not stored Value Range ...

Page 615: ...of Background Specifies the color used for the label background for the corresponding button Click Choose to select a color Default White Value Range Any color Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References None Font Size Specifies the size of the font on the label for the corresponding button Default 8 Value Rang...

Page 616: ...u want to print a key label template Default T7633 T7636 Value Range T7633 T7636 T7625 T7630 NT136 T7665 NT265 NT321 T7667 NT343 NT346 DT346 DT343 DT333 NT343 NT346 with 60CO Other Maintenance Console Location 6 5 4 1 4 Wired Extension Flexible Button Programming Manual References None Feature Manual References None 616 PC Programming Manual Document Version 2009 12 6 5 4 1 4 Wired Extension Flexi...

Page 617: ...can be selected To select all extensions at once click Select All When selecting multiple extensions note that if the source extension has an SDN button the copy operation cannot be performed Maintenance Console Location 6 6 4 1 4 Wired Extension Flexible Button Flexible button data copy Programming Manual References 6 5 4 1 4 Wired Extension Flexible Button Feature Manual References None Document...

Page 618: ...Value Range Not Stored One Touch Maintenance Console Location 6 7 4 1 5 Wired Extension PF Button Programming Manual References None Feature Manual References 6 1 3 Flexible Buttons Dial Specifies the number to be dialed Default Not stored Value Range Max 32 digits consisting of 0 9 T Transfer Secret P Pause and F Flash Maintenance Console Location 6 7 4 1 5 Wired Extension PF Button Programming M...

Page 619: ...the network for the selected extension This setting is automatically set to ON when the feature is used and can only be manually changed from ON to OFF to cancel data transmission Default OFF Value Range OFF ON Maintenance Console Location 6 8 4 1 6 Wired Extension NDSS Link Data Send Programming Manual References 11 1 9 1 TIE Table Feature Manual References 13 1 17 Private Network Features NDSS N...

Page 620: ...anual Shelf Indicates the shelf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console Location 6 9 4 1 7 Wired Extension Simplified Voice Message Programming Manual References None Feature Manual References None Slot Indicates the slot position reference only Default Current slot number Value Range Slot number Maintenance Console Location 6 9 4 1 7 Wired E...

Page 621: ...ces None Extension Number Indicates the extension number reference only Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 9 4 1 7 Wired Extension Simplified Voice Message Programming Manual References 3 39 1 2 Portable Station Feature Manual References None Extension Name Indicates the name of the extension reference only Document Version 2009 12 PC Progr...

Page 622: ... use the assigned card block If two cards are used in the PBX you should assign a number of extensions to each card to ensure that the necessary resources such as message recording space are available for each extension Default Card1 A Value Range None Card1 A Card1 B Card2 A Card2 B Maintenance Console Location 6 9 4 1 7 Wired Extension Simplified Voice Message Programming Manual References None ...

Page 623: ...nsole Location 6 9 4 1 7 Wired Extension Simplified Voice Message Programming Manual References None Feature Manual References None Document Version 2009 12 PC Programming Manual 623 6 9 4 1 7 Wired Extension Simplified Voice Message ...

Page 624: ... for more details Main Extension Number Indicates the extension number of the PS reference only Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Extension No Feature Manual References None Extension Name Specifies the name of the PS Default Not stored Val...

Page 625: ...one Extension Group Specifies the extension user group to which the PS belongs The extension user group is used to compose tenants call pickup groups and paging groups Default 1 Value Range 1 32 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 7 1 1 GROUP FEATURES 17 1 3 Tenant Service Document Version 2009 12 ...

Page 626: ...tion code PIN or extension PIN of the PBX The cost of such calls will be billed to the owner renter of the PBX To protect the PBX from this kind of fraudulent use we strongly recommend a Keeping PINs secret b Selecting complex random PINs that cannot be easily guessed c Changing PINs frequently Default Not stored Value Range Max 10 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 P...

Page 627: ...Max 20 characters Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Extension Name Feature Manual References None Intercept Destination When called party does not answer Day Lunch Break Night Specifies the Intercept Routing destination of calls in each time mode for Intercept Routing No Answer and Intercept Routing D...

Page 628: ...rty is Busy Specifies the Intercept Routing destination of calls when the extension is busy Default Not stored Value Range Max 32 digits consisting of 0 9 Secret and P Pause Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 9 1 11 Intercept Routing Intercept No Answer Time Extension Number Indicates the extensio...

Page 629: ...ettings Programming Manual References 3 39 1 2 Portable Station Extension Name Feature Manual References None Intercept No Answer Time Day Lunch Break Night Specifies the length of time until an unanswered call is redirected to the intercept routing destination in each time mode When this setting is set to 0 the system timer is used Default 0 Value Range 0 240 s Maintenance Console Location 6 10 4...

Page 630: ... of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Extension No Feature Manual References None Extension Name Specifies the name of the PS Default Not stored Value Range Max 20 characters Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable...

Page 631: ...IP number to show on the called party s telephone Default Extension Value Range Extension Show the CLIP number specified in CLIP ID on the Option 1 tab CO Show the CLIP number specified in Subscriber Number in 3 31 1 1 Slot Port Property PRI Port Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 31 1 1 Slot Port Property PRI Port CO Setting...

Page 632: ...n Presentation COLR Specifies whether to restrict the display of the CLIP number of the PS on the caller s telephone display when answering a call Default Disable Value Range Disable Enable Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation Option 1 Extension N...

Page 633: ...s the name of the PS Default Not stored Value Range Max 20 characters Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Extension Name Feature Manual References None Ring Pattern Table Specifies the Ring Tone Pattern Table to be used by the PS Default 1 Value Range 1 8 Document Version 2009 12 PC Programming Manual 6...

Page 634: ...6 digits consisting of 0 9 and Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 19 1 5 Voice Mail DTMF Integration Transfer Recall Destination Specifies the transfer recall destination when an extension user transfers a call with the Call Transfer without Announcement feature and the transferred call is not ans...

Page 635: ...ortable Station Extension Settings Programming Manual References 10 6 8 5 Carrier Feature Manual References 19 1 1 Verification Code Entry 1 1 3 ARS Automatic Route Selection Option 2 Extension Number Indicates the extension number of the PS reference only Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Progr...

Page 636: ... References None Manual C Waiting for Extension Call Selects the method of receiving call waiting notification from other extensions Default BSS Value Range Off No notification BSS Tone from the handset or built in speaker Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 3 1 11 CALL WAITING FEATURES 636 PC Prog...

Page 637: ...umber specified in Pickup Dial No on this screen is dialed automatically after going off hook when the Hot Line feature is active Default Off Value Range Off On Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 4 5 2 3 Timers Counters Dial IRNA Recall Tone Dial Hot Line Pickup Dial Start Feature Manual References 8 1 6 Hot Line Pickup Dial No...

Page 638: ...ates the extension number of the PS reference only Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Feature Manual References None Extension Name Specifies the name of the PS Default Not stored Value Range Max 20 characters 638 PC Programming Manual Docum...

Page 639: ...S Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 3 1 8 Call Pickup Executive Override Deny Specifies whether calls can be interrupted by other extensions Default Disable Value Range Disable Allows other extension users to interrupt an existing call Enable Prevents other extension users from interrupting an ex...

Page 640: ...Settings Programming Manual References None Feature Manual References 1 1 1 Absent Message Option 4 Extension Number Indicates the extension number of the PS reference only Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Feature Manual References None 64...

Page 641: ...n an idle PDN button is selected F 1 F 12 A CO line programmed for a flexible button F 1 F 12 is seized A flexible button customized as a Single CO Group CO Loop CO or ICD Group button must be selected Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 6 13 4 2 3 Portable Station Flexible Button Feature Manual References 10 1 3 Line Preference...

Page 642: ...Manual References 6 13 4 2 3 Portable Station Flexible Button Feature Manual References 10 1 2 Line Preference Incoming Call Waiting Tone Type Selects the type of Call Waiting tone sent to the busy extension Default CW Tone 1 Value Range CW Tone 1 CW Tone 2 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 3 1 1...

Page 643: ...on number of the PS reference only Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Extension No Feature Manual References None Extension Name Specifies the name of the PS Default Not stored Value Range Max 20 characters Document Version 2009 12 PC Progra...

Page 644: ... 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 4 1 9 Display Information Incoming Call Display Selects which caller information is shown on the first line of the PS s display Default Caller ID Name Value Range Caller ID Name CO Line Name DID Name Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual Refer...

Page 645: ...ming Manual References None Feature Manual References 4 1 9 Display Information Option 6 Extension Number Indicates the extension number of the PS reference only Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Feature Manual References None Extension Nam...

Page 646: ...s set to One touch Dial there is no need to enter 2 before the number when customizing a One touch Dialing button Default No Limitation Value Range No Limitation One touch Dial Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 12 1 4 One touch Dialing SVM Lock Selects whether Simplified Voice Message Log informa...

Page 647: ...e Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Feature Manual References None Extension Name Specifies the name of the PS Default Not stored Value Range Max 20 characters Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 ...

Page 648: ...ne Feature Manual References None Flash Mode during CO Conversation Selects the function of the FLASH RECALL button during a CO line conversation Default EFA Value Range EFA Terminate Flash Recall Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 6 1 2 Flash Recall Terminate 5 1 1 EFA External Feature Access 648...

Page 649: ...es the number of telephone numbers dialed by the PS that are retained in the PS s Outgoing Call Log memory Default 5 Value Range 1 100 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References 15 1 1 Redial Last Number ISDN Bearer Selects the ISDN bearer mode When Automatic is selected the bearer mode is set automatical...

Page 650: ...es the extension number of the PS reference only Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Feature Manual References None Extension Name Specifies the name of the PS Default Not stored Value Range Max 20 characters 650 PC Programming Manual Documen...

Page 651: ...Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References None Feature Manual References None Wrap up Timer Specifies the length of time that must pass after completing a call before a PS will accept another call when logged in as a member of an Incoming Call Distribution Group This timer is used when Options Wrap up Timer based on is set to Extension in 5 15 3 5 3 Inco...

Page 652: ...ult Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Feature Manual References None Extension Name Specifies the name of the PS Default Not stored Value Range Max 20 characters Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programmin...

Page 653: ...cifies whether to enable or disable the Communication Assistant CA application for each extension Default Enable Value Range Disable Basic Only Enable Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 4 1 1 Slot Card Property IPCMPR Port Number Built in Communication Assistant Server Feature Manual References 3 1 1 CA Communication Assistan...

Page 654: ...Extension Name Specifies the name of the PS Default Not stored Value Range Max 20 characters Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 3 39 1 2 Portable Station Extension Name Feature Manual References None FWD Set for Call from CO Indicates the current FWD status for incoming CO line calls reference only Default Off Value Range Off O...

Page 655: ...2 1 Portable Station Extension Settings Programming Manual References 6 12 4 2 2 Portable Station FWD DND Feature Manual References 4 1 10 DND Do Not Disturb FWD Mode for Call from CO Indicates the forwarding type of incoming CO line calls reference only Default None Value Range None FWD All FWD Busy FWD N A FWD Busy N A Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings P...

Page 656: ...eature Manual References 6 1 6 FWD Call Forwarding FWD Set for Call from Extension Indicates the current FWD status for incoming intercom calls reference only Default Off Value Range Off On Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 6 12 4 2 2 Portable Station FWD DND Feature Manual References 6 1 6 FWD Call Forwarding DND Set for Call...

Page 657: ...alue Range None FWD All FWD Busy FWD N A FWD Busy N A Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 6 12 4 2 2 Portable Station FWD DND Feature Manual References 6 1 6 FWD Call Forwarding FWD Destination for Call from Extension Indicates the forwarding destination of incoming intercom calls reference only Default Not stored Value Range Ma...

Page 658: ...the length of time that an incoming call rings at the PS before the call is forwarded reference only Default 15 s Value Range 0 120 s Maintenance Console Location 6 10 4 2 1 Portable Station Extension Settings Programming Manual References 6 12 4 2 2 Portable Station FWD DND Feature Manual References 6 1 6 FWD Call Forwarding 658 PC Programming Manual Document Version 2009 12 6 10 4 2 1 Portable S...

Page 659: ... Settings CLIP Generate Programming Manual References 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation Location Entry Number to Generate Specifies the number of locations to be programmed A CLIP number will only be assigned to registered PS extensions even if the number entered here is larger than the total number of PS e...

Page 660: ...5 CLIP Calling Line Identification Presentation Parameter Head of ID Specifies a prefix number to be applied to all generated CLIP numbers Default Not stored Value Range Max 16 digits consisting of 0 9 and Maintenance Console Location 6 11 4 2 1 Portable Station Extension Settings CLIP Generate Programming Manual References 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 3...

Page 661: ...able Station Extension Settings CLIP Generate Programming Manual References 6 10 4 2 1 Portable Station Extension Settings Feature Manual References 3 1 15 CLIP Calling Line Identification Presentation Document Version 2009 12 PC Programming Manual 661 6 11 4 2 1 Portable Station Extension Settings CLIP Generate ...

Page 662: ...nsole Location 6 12 4 2 2 Portable Station FWD DND Programming Manual References None Feature Manual References 4 1 10 DND Do Not Disturb 6 1 6 FWD Call Forwarding Forward DND For internal calls Specifies the FWD DND setting for internal calls If Always All Busy No Answer or Busy No Answer is selected the FWD destination field can be set If For both external calls and internal calls is checked thi...

Page 663: ...at an incoming call rings at the PS before the call is forwarded Default 15 s Value Range 0 120 s Maintenance Console Location 6 12 4 2 2 Portable Station FWD DND Programming Manual References None Feature Manual References 6 1 6 FWD Call Forwarding Document Version 2009 12 PC Programming Manual 663 6 12 4 2 2 Portable Station FWD DND ...

Page 664: ...DND External FWD DND Internal Group Fwd Both Group Fwd External Group Fwd Internal Account Conference Terminate EFA Call Park Log in Log out Hurry up Wrap up Time Service TRS Level Change CLIR COLR Time Service Automatic Manual Two way Record Two way Transfer LCS Voice Mail Transfer NDSS CTI PDN SDN Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual Referen...

Page 665: ...or Call Park Specifies whether a call is parked in an idle parking zone automatically or in a specific parking zone Default Automatic Value Range Automatic Specific Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References None Feature Manual References 3 1 7 Call Park Parameter Selection for Log in Log out Specifies which incoming call distribution gro...

Page 666: ... in Log out Parameter Selection for Time Service Selects which time modes are switched manually Default All Value Range All Day Night Lunch Break Day Night Break Day Night Lunch Day Night Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 4 6 2 4 Week Table Feature Manual References 17 1 5 Time Service Parameter Selection for TRS Level Change Spe...

Page 667: ...ation 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 4 6 2 4 Week Table Feature Manual References 17 1 5 Time Service Parameter Selection for SDN Specifies the delayed ringing setting for calls arriving at an SDN button The value specified here is only used when System Wireless SDN Delayed Ringing with LCD on 4 18 2 9 System Options is set to Enable Default Immediate Val...

Page 668: ...3 Portable Station Flexible Button Programming Manual References None Feature Manual References None Ext No Floating Ext No for G DN Specifies the floating extension number of an incoming call distribution group to be accessed Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 5 12 3 5...

Page 669: ... Specifies the floating extension number of an incoming call distribution group for which both intercom and CO line calls are forwarded Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 5 12 3 5 1 Incoming Call Distribution Group Group Settings Group Log Group FWD Feature Manual Refer...

Page 670: ...ed Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 5 12 3 5 1 Incoming Call Distribution Group Group Settings Group Log Group FWD Feature Manual References 6 1 6 FWD Call Forwarding Ext No Floating Ext No for Log in Log out Specifies the floating extension number of an incoming call distribution group...

Page 671: ... Button Programming Manual References 5 12 3 5 1 Incoming Call Distribution Group Group Settings Overflow No Answer Feature Manual References 9 1 6 ICD Group Features Queuing Ext No Floating Ext No for Two way Record Specifies the floating extension number of the VM DPT group containing the PS s mailbox Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 13...

Page 672: ...ontaining the desired mailbox Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 5 19 3 7 2 VM DPT Group Unit Settings 5 22 3 8 2 VM DTMF Group Group Settings Feature Manual References 19 1 5 Voice Mail DTMF Integration 19 1 4 Voice Mail DPT Digital Integration Ext No Floating Ext No f...

Page 673: ...9 T Transfer Secret P Pause and F Flash Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References None Feature Manual References 12 1 4 One touch Dialing Dial for NDSS Specifies the network extension number of the extension to be accessed using Network Direct Station Selection Note that only extension numbers that have been previously registered in 11 4...

Page 674: ... Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 4 6 2 4 Week Table Feature Manual References 17 1 5 Time Service Optional Parameter or Ringing Tone Type Number for Call Park Specifies the number of the parking zone a call is to be parked in when a Call Park button with Parameter Selection for Call Park on this screen set to Specific is pressed Default 0 ...

Page 675: ...ible Button Programming Manual References None Feature Manual References 19 1 4 Voice Mail DPT Digital Integration Display Option Key Setting Key Label Name Type This parameter is equivalent to Type on the Key Setting screen Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 6 13 4 2 3 Portable Station Flexible Button Display Option Key Setting T...

Page 676: ... None Dial This parameter is equivalent to Dial on the Key Setting screen Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 6 13 4 2 3 Portable Station Flexible Button Display Option Key Setting Dial for One touch Dial for NDSS Feature Manual References None Parameter 1 This parameter is equivalent to Parameter Selection on the Key Setting scree...

Page 677: ...e Button Display Option Key Setting Optional Parameter or Ringing Tone Type Number for Time Service Optional Parameter or Ringing Tone Type Number for Call Park Feature Manual References None Mailbox Number This parameter is equivalent to Ext No of Mailbox on the Key Setting screen Maintenance Console Location 6 13 4 2 3 Portable Station Flexible Button Programming Manual References 6 13 4 2 3 Por...

Page 678: ...ll PSs at once click Select All When selecting multiple extensions note that if the source extension has an SDN button the copy operation cannot be performed Maintenance Console Location 6 14 4 2 3 Portable Station Flexible Button Flexible button data copy Programming Manual References 6 13 4 2 3 Portable Station Flexible Button Feature Manual References None 678 PC Programming Manual Document Ver...

Page 679: ... network for the selected extension This setting is automatically set to ON when the feature is used and can only be manually changed from ON to OFF to cancel data transmission Default OFF Value Range OFF ON Maintenance Console Location 6 15 4 2 4 Portable Station NDSS Link Data Send Programming Manual References 11 4 9 4 NDSS Key Table Feature Manual References 13 1 17 Private Network Features ND...

Page 680: ...red Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 16 4 2 5 Portable Station Simplified Voice Message Programming Manual References 3 39 1 2 Portable Station Feature Manual References None Extension Name Indicates the name of the extension reference only Default Not stored Value Range Max 20 characters Maintenance Console Location 6 16 4 2 5 Portable Station Simplified V...

Page 681: ...ard1 A Value Range None Card1 A Card1 B Card2 A Card2 B Maintenance Console Location 6 16 4 2 5 Portable Station Simplified Voice Message Programming Manual References None Feature Manual References 16 1 8 SVM Simplified Voice Message Maximum of SVM Log Specifies the maximum number of voice messages not including greeting messages that can be stored for the extension Default 10 Value Range 1 100 M...

Page 682: ...Key Label File drop down list Note that it is necessary to save these settings separately from system data For more information on flexible buttons see 6 1 3 Flexible Buttons in the Feature Manual Pair Extension Specifies the extension number of the PT to be used in pair with the DSS Console Note that if one or more SDN buttons have been set at the DSS Console they must be deleted before this sett...

Page 683: ...anual References 6 1 3 Flexible Buttons Parameter Selection for Single CO Specifies the CO line to be accessed Default 1 Value Range 1 128 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References 6 18 4 3 DSS Console DSS key data copy Feature Manual References 3 1 16 CO Line Access Parameter Selection for Group CO Specifies the trunk group to be accessed Default 1 Value Rang...

Page 684: ...ture Manual References 3 1 7 Call Park Parameter Selection for Log in Log out Specifies which incoming call distribution groups that the paired extension belongs to are logged in to or logged out from Default None Value Range None The incoming call distribution group is selected manually All All incoming call distribution groups that the paired extension belongs to Incoming Group A pre specified i...

Page 685: ...ual References 4 6 2 4 Week Table Feature Manual References 17 1 5 Time Service Parameter Selection for TRS Level Change Specifies the TRS level to be used temporarily on a certain extension Default 1 Value Range 1 7 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References 4 12 2 7 1 Class of Service COS Settings TRS Section 9 7 TRS Feature Manual References 17 1 6 TRS Toll ...

Page 686: ... delayed ringing setting for calls arriving at an SDN button Default Immediate Value Range Immediate 1 Ring 2 Rings 3 Rings 4 Rings 5 Rings 6 Rings No Ring Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Manual References 13 1 7 PDN Primary Directory Number SDN Secondary Directory Number Extension Ext No Floating Ext No for DSS Specifies the number of a...

Page 687: ... 12 3 5 1 Incoming Call Distribution Group Group Settings Feature Manual References 9 1 1 ICD GROUP FEATURES Ext No Floating Ext No for Message Waiting Specifies the number of an extension or floating extension number of an incoming call distribution group for which messages are checked If this cell is left empty the paired extension will check its own messages only Default Not stored Value Range ...

Page 688: ...ion Group Group Settings Group Log Group FWD Feature Manual References 6 1 6 FWD Call Forwarding Ext No Floating Ext No for Group Fwd External Specifies the floating extension number of an incoming call distribution group for which CO line calls are forwarded Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual Reference...

Page 689: ...ifies the paired extension s number or the floating extension number of an incoming call distribution group for which call log information is displayed If the cell is left empty the paired extension will display its own call log information Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Manu...

Page 690: ...ue Redirection Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References 5 12 3 5 1 Incoming Call Distribution Group Group Settings Overflow No Answer Feature Manual References 9 1 6 ICD Group Features Queuing Ext No Floating Ext No for Two way Record Specifies the floating extension number of the VM DPT group cont...

Page 691: ...DPT Group Unit Settings Feature Manual References 19 1 4 Voice Mail DPT Digital Integration Ext No Floating Ext No for Voice Mail Transfer Specifies the floating extension number of the VM DTMF DPT group containing the desired mailbox Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References 5 19 3 7 2 VM DPT Group...

Page 692: ...One touch Specifies the number to be dialed The PBX can have a maximum of 2000 One touch Dialing buttons for extensions and DSS Consoles Default Not stored Value Range Max 32 digits consisting of 0 9 T Transfer Secret P Pause and F Flash Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Manual References 12 1 4 One touch Dialing Dial for NDSS Specifies th...

Page 693: ... Switching mode Default 1 Value Range 1 8 Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References 4 6 2 4 Week Table Feature Manual References 17 1 5 Time Service Optional Parameter Ringing Tone Type Number for Loop CO Single CO Group CO G DN SDN Specifies the ring tone type Default 1 Value Range KX DT300 series except KX DT321 KX T7600 series IP PT except KX NT265 KX NT321...

Page 694: ... Location 6 17 4 3 DSS Console Programming Manual References None Feature Manual References 3 1 7 Call Park Ext No of Mailbox for Two way Transfer Specifies the number of the extension whose mailbox will be used to record conversations using One touch Two way Transfer For example a secretary can record a conversation into the mailbox of a boss If the cell is left empty the extension user must spec...

Page 695: ...ual References None Extension Number This parameter is equivalent to Ext No Floating Ext No on the Key Setting screen Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References 6 17 4 3 DSS Console Display Option Key Setting Ext No Floating Ext No for DSS Ext No Floating Ext No for G DN Ext No Floating Ext No for Message Waiting Ext No Floating Ext No for Group Fwd Both Ext No...

Page 696: ...sole Location 6 17 4 3 DSS Console Programming Manual References 6 17 4 3 DSS Console Display Option Key Setting Parameter Selection for Single CO Parameter Selection for Group CO Parameter Selection for Call Park Parameter Selection for Log in Log out Parameter Selection for Time Service Parameter Selection for TRS Level Change Parameter Selection for Time Service Automatic Manual Parameter Selec...

Page 697: ...arameter is equivalent to Ext No of Mailbox on the Key Setting screen Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References 6 17 4 3 DSS Console Display Option Key Setting Ext No of Mailbox for Two way Transfer Feature Manual References None Label Specifies the label that will be printed next to the corresponding button Default Not stored Value Range Max 20 characters Mai...

Page 698: ...one Color of Background Specifies the color used for the label background for the corresponding button Click Choose to select a color Default White Value Range Any color Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Manual References None Font Size Specifies the size of the font on the label for the corresponding button Default 8 Value Range 4 15 698 ...

Page 699: ...pe DSS Type Selects the type of DSS Console for which you want to print a key label template Default T7640 Value Range T7640 DT390 Other Maintenance Console Location 6 17 4 3 DSS Console Programming Manual References None Feature Manual References None Document Version 2009 12 PC Programming Manual 699 6 17 4 3 DSS Console ...

Page 700: ...ole Select the number of the DSS Console and paired extension Multiple DSS Consoles can be selected To select all DSS Consoles at once click Select All When selecting multiple extensions note that if the source extension has an SDN button the copy operation cannot be performed Maintenance Console Location 6 18 4 3 DSS Console DSS key data copy Programming Manual References 6 17 4 3 DSS Console Fea...

Page 701: ...Section 7 5 Optional Device Document Version 2009 12 PC Programming Manual 701 ...

Page 702: ...ue Range Slot and sub slot number Maintenance Console Location 7 1 5 1 Doorphone Programming Manual References None Feature Manual References 4 1 12 Doorphone Call Physical Location Port Indicates the port number to which the doorphone is connected reference only Default Current port number Value Range Port number Maintenance Console Location 7 1 5 1 Doorphone Programming Manual References None Fe...

Page 703: ...hone calls for each port in each time mode Default Not stored Value Range Max 32 digits consisting of 0 9 Secret and P Pause Maintenance Console Location 7 1 5 1 Doorphone Programming Manual References 4 6 2 4 Week Table Feature Manual References 4 1 12 Doorphone Call Tenant Number Specifies the tenant number for the doorphone port in order to apply the Time Table day lunch break night Default 1 V...

Page 704: ...hone Programming Manual References 4 12 2 7 1 Class of Service COS Settings TRS TRS Level Day Lunch Break Night 4 14 2 7 3 Class of Service Internal Call Block Feature Manual References 9 1 14 Internal Call Block 4 1 12 Doorphone Call VM Trunk Group Number Specifies the number of the VM trunk group sent to the VPS when the doorphone call destination is the floating extension number of a VM DPT gro...

Page 705: ...Programming Manual References None Feature Manual References 4 1 12 Doorphone Call 19 1 4 Voice Mail DPT Digital Integration Document Version 2009 12 PC Programming Manual 705 7 1 5 1 Doorphone ...

Page 706: ...stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 7 2 5 2 External Pager Programming Manual References None Feature Manual References 13 1 1 Paging 17 1 2 TAFAS Trunk Answer From Any Station 2 1 1 BGM Background Music Page Number 1 Page Number 2 Name Specifies the name of the external pager Default Not stored Value Range Max 20 characters Maintenance Console Location 7...

Page 707: ...17 1 2 TAFAS Trunk Answer From Any Station 2 1 1 BGM Background Music Document Version 2009 12 PC Programming Manual 707 7 2 5 2 External Pager ...

Page 708: ... and CO line calls can be made Trunk Intercom calls and TIE line calls without PBX code can be made TIE line calls with PBX code and CO line calls are restricted All All calls are restricted Maintenance Console Location 7 3 5 3 1 Voice Message DISA System Programming Manual References None Feature Manual References 19 1 1 Verification Code Entry 20 1 1 Walking COS DISA Security Remote Walking COS ...

Page 709: ...ion 7 3 5 3 1 Voice Message DISA System Programming Manual References None Feature Manual References None DISA Intercept Intercept when all DISA ports are busy Selects how DISA calls are handled if all DISA ports are currently in use Default to Operator Value Range to Operator to AA 0 to AA 9 Disable Busy Tone Maintenance Console Location 7 3 5 3 1 Voice Message DISA System Programming Manual Refe...

Page 710: ... Transfer to Public CO on this screen should be set to Enable Setting this to Disable will free up DISA ports faster but prevent DISA being used to detect the end of a call and disconnect the CO line quickly Default Enable Value Range Disable Release DISA The DISA port of the message card is released when a CO to CO line call using DISA is established Enable DISA stays connected for the duration o...

Page 711: ...ection of the end of the call Maintenance Console Location 7 3 5 3 1 Voice Message DISA System Programming Manual References 7 3 5 3 1 Voice Message DISA System Option 1 CO CO with DISA Fwd Transfer to Private Network Feature Manual References None CO CO with DISA Fwd Transfer to Public CO Enables CO to CO line calls to be established using DISA Default Disable Value Range Disable CO to CO line ca...

Page 712: ...ey Required Specifies whether an outside party such as a cellular phone can transfer a CO line call to an extension within the PBX by dialing extension number Default Disable Value Range Disable is ignored if dialed Enable as Flash The current CO line call will be placed on hold then transferred to the extension whose number is entered Maintenance Console Location 7 3 5 3 1 Voice Message DISA Syst...

Page 713: ...eps below 1 Change this setting 2 Set the status of the OPB3 card to OUS then INS Default Fixed Value Range Fixed The number of times of a tone pattern a set of tone on and tone off that the PBX receives is fixed to 4 times in the ranges of A B C D C C D D A B 100 1300 ms C A 90 ms D B 90 ms Option The tone pattern that the PBX receives is optional as specified in DISA Cyclic Tone Option on this s...

Page 714: ... System Programming Manual References 3 1 1 1 Slot 3 36 1 1 Slot OPB3 Card Property Feature Manual References None DISA Cyclic Tone Option Tone Off Maximum Time Specifies the maximum time that the PBX waits for a cyclic tone to be sent from the telephone company before recognizing it as a tone off When no tone is detected within the time set here the PBX recognizes it as a tone off Note that this ...

Page 715: ...e Detection on this screen is set to Option Default 3 Value Range 3 16 Maintenance Console Location 7 3 5 3 1 Voice Message DISA System Programming Manual References None Feature Manual References None Timed Reminder Message Day Lunch Break Night Specifies the prerecorded message to play when a Timed Reminder call is answered in each time mode Default None Value Range None 1 64 Maintenance Console...

Page 716: ...nge this setting 2 Set the status of the OPB3 card to OUS then INS Default High Value Range Low About 120 minutes of messages can be recorded per card Middle About 60 minutes of messages can be recorded per card High About 20 minutes of messages can be recorded per card Maintenance Console Location 7 3 5 3 1 Voice Message DISA System Programming Manual References None Feature Manual References 16 ...

Page 717: ...GM 01 64 501 564 Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 7 4 5 3 2 Voice Message DISA Message Programming Manual References None Feature Manual References 12 1 2 OGM Outgoing Message 4 1 8 DISA Direct Inward System Access Name Specifies the name of the OGM Default OGM 01 xx DISA 01 DISA xx Value Range Max 20 characters Maintenance Console Location 7 4 5 3 2 Voice Me...

Page 718: ... 12 1 2 OGM Outgoing Message 4 1 8 DISA Direct Inward System Access Busy DND Message No Selects the OGM to be played for the caller when the destination party is busy or sets DND Default None Value Range None 1 64 Maintenance Console Location 7 4 5 3 2 Voice Message DISA Message Programming Manual References 7 3 5 3 1 Voice Message DISA System Feature Manual References 4 1 8 DISA Direct Inward Sys...

Page 719: ... Maintenance Console Location 7 4 5 3 2 Voice Message DISA Message Programming Manual References None Feature Manual References 1 1 6 Automatic Fax Transfer Document Version 2009 12 PC Programming Manual 719 7 4 5 3 2 Voice Message DISA Message ...

Page 720: ...ssage SVM Programming Manual References None Feature Manual References 16 1 8 SVM Simplified Voice Message SVM Card No 1 2 Floating Extension Number Specifies the floating extension number used to access the SVM feature Default Card No 1 591 Card No 2 592 Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 7 5 5 3 3 Voice Message SVM Programming Manual References None Feature M...

Page 721: ...Value Range Low About 120 minutes of messages can be recorded Middle About 60 minutes of messages can be recorded High About 40 minutes IPCMPR 20 minutes ESVM of messages can be recorded Maintenance Console Location 7 5 5 3 3 Voice Message SVM Programming Manual References 6 9 4 1 7 Wired Extension Simplified Voice Message 6 16 4 2 5 Portable Station Simplified Voice Message Feature Manual Referen...

Page 722: ...ox To apply changes to this setting follow the steps below 1 Change this setting 2 Set the status of the IPCMPR card or OPB3 card to OUS then INS See 3 5 1 1 Slot OPB3 Card Property or 3 36 1 1 Slot OPB3 Card Property Default Fixed Value Range Fixed The number of times of a tone pattern a set of tone on and tone off that the PBX receives is fixed to 4 times in the ranges of A B C D C C D D A B 100...

Page 723: ...7 5 5 3 3 Voice Message SVM Programming Manual References 3 1 1 1 Slot Feature Manual References 16 1 8 SVM Simplified Voice Message SVM Cyclic Tone Option Tone Off Maximum Time Specifies the maximum time that the PBX waits for a cyclic tone to be sent from the telephone company before recognizing it as a tone off When no tone is detected within the time set here the PBX recognizes it as a tone of...

Page 724: ...st be received to establish reception of the cyclic tone This determines the end of call Note that this option can only be set when SVM Cyclic Tone Detection on this screen is set to Option Default 3 Value Range 3 16 Maintenance Console Location 7 5 5 3 3 Voice Message SVM Programming Manual References None Feature Manual References 16 1 8 SVM Simplified Voice Message 724 PC Programming Manual Doc...

Page 725: ... References None Feature Manual References 5 1 8 External Relay Physical Location Slot Indicates the slot position reference only Default Current slot and sub slot number Value Range Slot and sub slot number Maintenance Console Location 7 6 5 4 External Relay Programming Manual References None Feature Manual References 5 1 8 External Relay Physical Location Port Indicates the port number reference...

Page 726: ...cifies the relay name Default Not stored Value Range Max 20 characters Maintenance Console Location 7 6 5 4 External Relay Programming Manual References None Feature Manual References 5 1 8 External Relay Relay Activate Time Specifies the length of time that the relay stays on when activated Default 5 s Value Range 1 7 s 726 PC Programming Manual Document Version 2009 12 7 6 5 4 External Relay ...

Page 727: ...tensions that are able to activate relays Default 1 Value Range 1 64 Maintenance Console Location 7 6 5 4 External Relay Programming Manual References 4 12 2 7 1 Class of Service COS Settings Optional Device Other Extensions External Relay Access Feature Manual References 3 1 21 COS Class of Service 5 1 8 External Relay 9 1 14 Internal Call Block Document Version 2009 12 PC Programming Manual 727 ...

Page 728: ...alue Range 1 16 Maintenance Console Location 7 7 5 5 External Sensor Programming Manual References None Feature Manual References 5 1 9 External Sensor Physical Location Slot Indicates the slot position reference only Default Current slot and sub slot number Value Range Slot and sub slot number Maintenance Console Location 7 7 5 5 External Sensor Programming Manual References None Feature Manual R...

Page 729: ...the sensor name Default Sensor Value Range Max 20 characters Maintenance Console Location 7 7 5 5 External Sensor Programming Manual References None Feature Manual References 5 1 9 External Sensor Destination Day Lunch Break Night Specifies the destination number of sensor calls for each port in each time mode Default Not stored Value Range Max 32 digits consisting of 0 9 Secret and P Pause Docume...

Page 730: ...nsor belongs to determine the Time Table for the sensor The tenant number corresponds to the Time Table number Default 1 Value Range 1 8 Maintenance Console Location 7 7 5 5 External Sensor Programming Manual References 4 6 2 4 Week Table Feature Manual References 5 1 9 External Sensor 17 1 3 Tenant Service 730 PC Programming Manual Document Version 2009 12 7 7 5 5 External Sensor ...

Page 731: ...Section 8 6 Feature Document Version 2009 12 PC Programming Manual 731 ...

Page 732: ...lects the System Speed Dialing Table to be programmed Whether a tenant uses the basic System Speed Dialing Table or the additional table depends on the setting of System Speed Dial in 8 6 6 6 Tenant Default Basic Memory Value Range Basic Memory the standard table Expansion for Tenant 1 8 additional tables Maintenance Console Location 8 1 6 1 System Speed Dial Programming Manual References 8 6 6 6 ...

Page 733: ... to which incoming calls from the programmed telephone number are routed If a Caller ID Modification Table is being used the modified number must match the telephone number above CO Line Access Number Telephone Number in order for the call to be routed correctly Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 8 1 6 1 System Speed Dial Programming Manual R...

Page 734: ...ences None Feature Manual References 8 1 4 HOSPITALITY FEATURES 15 1 3 Room Status Control SMDR for External Hotel Application 1 Room Status Control Selects whether check in and check out data is output on SMDR Default No Print Value Range No Print Print Maintenance Console Location 8 2 6 2 Hotel Programming Manual References 13 1 11 1 Main Feature Manual References 16 1 3 SMDR Station Message Det...

Page 735: ...cifies the text of the message output on SMDR when this Printing Message is selected from an extension The character can be used in a message and requires a number to be entered in its place when the message is selected from an extension This character can be used a maximum of seven times in a Printing Message Default Not stored Value Range Max 16 characters Maintenance Console Location 8 2 6 2 Ho...

Page 736: ...on Code Specifies the verification code Default Not stored Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 8 3 6 3 Verification Code Programming Manual References None Feature Manual References 19 1 1 Verification Code Entry User Name Specifies the user name assigned to the verification code Default Not stored Value Range Max 20 characters Maintenance Console Location 8...

Page 737: ... PINs that cannot be easily guessed c Changing PINs frequently Default Not stored Value Range Max 10 digits consisting of 0 9 Maintenance Console Location 8 3 6 3 Verification Code Programming Manual References None Feature Manual References 19 1 1 Verification Code Entry COS Number Specifies the COS that applies when making a CO line call with the verification code Default 1 Value Range 1 64 Main...

Page 738: ...for accounting and billing purposes Default Not stored Value Range Max 10 digits consisting of 0 9 and Maintenance Console Location 8 3 6 3 Verification Code Programming Manual References 10 6 8 5 Carrier Feature Manual References 1 1 3 ARS Automatic Route Selection 738 PC Programming Manual Document Version 2009 12 8 3 6 3 Verification Code ...

Page 739: ...cable tab Second Dial Tone Waiting Code Specifies the Second Dial Tone Waiting code Default Not stored Value Range Max 4 digits consisting of 0 9 and Maintenance Console Location 8 4 6 4 Second Dial Tone Programming Manual References None Feature Manual References 13 1 4 Pause Insertion Pause Repeating Counter Specifies the number of pauses to be inserted when waiting for the second dial tone Defa...

Page 740: ...e of them Absent Message Specifies the message for display Default 1 Will Return Soon 2 Gone Home 3 At Ext Extension Number 4 Back at Hour Minute 5 Out until Month Day 6 In a Meeting 7 and 8 Not stored Value Range Max 16 characters Maintenance Console Location 8 5 6 5 Absent Message Programming Manual References None Feature Manual References 1 1 1 Absent Message 740 PC Programming Manual Document...

Page 741: ... BGM5 BGM6 BGM7 Tone Maintenance Console Location 8 6 6 6 Tenant Programming Manual References 4 4 2 2 Operator BGM Feature Manual References 11 1 4 Music on Hold 17 1 3 Tenant Service Operator Extension Number Specifies the extension number or the floating extension number of an incoming call distribution group to be designated as the tenant operator When this parameter is left unspecified the PB...

Page 742: ...d in ARS Mode in 10 1 8 1 System Setting is applied Maintenance Console Location 8 6 6 6 Tenant Programming Manual References 10 1 8 1 System Setting Feature Manual References 1 1 3 ARS Automatic Route Selection 17 1 3 Tenant Service System Speed Dial Specifies which system speed dialing table is used by the tenant Default Same as System Setting Value Range Same as System Setting PBX common system...

Page 743: ...Feature Manual References 16 1 7 Speed Dialing System 17 1 3 Tenant Service Document Version 2009 12 PC Programming Manual 743 8 6 6 6 Tenant ...

Page 744: ...744 PC Programming Manual Document Version 2009 12 8 6 6 6 Tenant ...

Page 745: ...Section 9 7 TRS Document Version 2009 12 PC Programming Manual 745 ...

Page 746: ...r are not found in the applicable Denied Code Tables the call is made A maximum of 100 denied codes can be programmed for each level 20 codes are displayed at a time To display other sets of codes click the applicable tab Denied Code Tables Level 2 Level 6 Specifies the leading digits of toll restricted numbers for each level Default Not stored Value Range Max 16 digits consisting of 0 9 and X Mai...

Page 747: ...licable Exception Code Tables and if a match is found the call is made A maximum of 100 exception codes can be programmed for each level 20 codes are displayed at a time To display other sets of codes click the applicable tab Exception Code Tables Level 2 Level 6 Specifies the leading digits of the numbers to be exempted from Toll Restriction for each level Default Not stored Value Range Max 16 di...

Page 748: ...e dialed number TRS will look only at the following digits A maximum of 20 Special Carrier Access Codes can be programmed Special Carrier Access Code Specifies a Special Carrier Access Code Special Carrier Access Codes and Host PBX Access codes should be unique Default Not stored Value Range Max 16 digits consisting of 0 9 and Maintenance Console Location 9 3 7 3 Special Carrier Programming Manual...

Page 749: ...mbers can be programmed Emergency Number Specifies the numbers used for making emergency calls It is not necessary to start the emergency number with a CO Line Access number Default 1 911 2 10 Not stored Value Range Max 32 digits consisting of 0 9 T Transfer P Pause and F Flash Maintenance Console Location 9 4 7 4 Emergency Dial Programming Manual References None Feature Manual References 5 1 2 Em...

Page 750: ...ntenance Console Location 9 5 7 5 Miscellaneous Programming Manual References 8 1 6 1 System Speed Dial Feature Manual References 17 1 6 TRS Toll Restriction TRS Check for Dial Enables a TRS check for the user dialed and This is useful in preventing unauthorized calls which could possibly be made through certain telephone company exchanges Default No Check Value Range No Check Check Maintenance Co...

Page 751: ...Restriction Dial Digits Limitation After Answering Dial Digits Specifies a limit to be placed on the number of digits which can be dialed after an extension user receives a CO line call If the number of dialed digits exceeds the programmed limit the line will be disconnected Default None Value Range None 1 7 Maintenance Console Location 9 5 7 5 Miscellaneous Programming Manual References None Feat...

Page 752: ...de Tables Default Deny Table 2_N Except Table N_6 Value Range Deny Table 2_N Except Table N_6 The Denied Code Tables for the higher levels are applied to all levels below it and the Exception Code Tables for the lower levels are applied to all levels above it Deny Table N Except Table N Each level has its own separate set of denied codes and exception codes which are only applied to that level Mai...

Page 753: ...Section 10 8 ARS Document Version 2009 12 PC Programming Manual 753 ...

Page 754: ...hen an extension user makes a call using Idle Line Access CO Line Access or S CO Line Access method Maintenance Console Location 10 1 8 1 System Setting Programming Manual References None Feature Manual References 3 1 16 CO Line Access 1 1 3 ARS Automatic Route Selection Mode When Any Carrier is not programmed for the Dial Selects what happens when the dialed number is not found in Leading Number ...

Page 755: ...Feature Manual References 1 1 3 ARS Automatic Route Selection Document Version 2009 12 PC Programming Manual 755 10 1 8 1 System Setting ...

Page 756: ...er of digits of the user dialed number excluding the leading number 100 leading numbers are displayed at a time To display other sets of leading numbers click the applicable tab Leading Number Specifies the leading number Default Not stored Value Range Max 16 digits consisting of 0 9 and X Maintenance Console Location 10 2 8 2 Leading Number Programming Manual References None Feature Manual Refere...

Page 757: ...ing Plan Table number used for each leading number Default 1 Value Range 1 16 Maintenance Console Location 10 2 8 2 Leading Number Programming Manual References None Feature Manual References 1 1 3 ARS Automatic Route Selection Document Version 2009 12 PC Programming Manual 757 10 2 8 2 Leading Number ...

Page 758: ...its own time blocks Select the desired Routing Plan Table number from the Routing Plan list To adjust the currently displayed Routing Plan click and drag the divisions between two time periods To program the time blocks of the currently displayed Routing Plan including adding or deleting time blocks click Time Setting 758 PC Programming Manual Document Version 2009 12 10 3 8 3 Routing Plan Time ...

Page 759: ...e Maintenance Console Location 10 4 8 3 Routing Plan Time Time Setting Programming Manual References None Feature Manual References 1 1 3 ARS Automatic Route Selection Time A D Hour Minute Specifies the start time for each time block Default Time A 8 00 Time B 17 00 Time C 21 00 Time D Not applicable Value Range 00 00 23 59 Maintenance Console Location 10 4 8 3 Routing Plan Time Time Setting Progr...

Page 760: ...ng the applicable tab Time A Time D Specifies the carrier to be given priority for each time zone Default Routing Plan 1 10 Priority 1 Routing Plan No Priority 2 6 None Routing Plan 11 16 Priority 1 6 None Value Range None 1 10 Maintenance Console Location 10 5 8 4 Routing Plan Priority Programming Manual References None Feature Manual References 1 1 3 ARS Automatic Route Selection 760 PC Programm...

Page 761: ... characters Maintenance Console Location 10 6 8 5 Carrier Programming Manual References None Feature Manual References 1 1 3 ARS Automatic Route Selection Removed Number of Digits Specifies the number of leading digits to remove from the user dialed number Default 0 Value Range 0 15 Maintenance Console Location 10 6 8 5 Carrier Programming Manual References None Feature Manual References 1 1 3 ARS...

Page 762: ...omatic Route Selection Carrier Access Code Specifies the carrier access code The carrier access code can be added to the user dialed number by specifying C in Modify Command on this screen Default Not stored Value Range Max 32 digits consisting of 0 9 and P Pause Maintenance Console Location 10 6 8 5 Carrier Programming Manual References None Feature Manual References 1 1 3 ARS Automatic Route Sel...

Page 763: ...or Tenant Specifies an Authorization code for each tenant The Authorization codes can be added to the user dialed number by specifying A command in Modify Command on the Carrier tab Authorization Code for Tenant Tenant 1 Tenant 8 Specifies the Authorization code of each carrier for each tenant Default Not stored Value Range Max 16 digits consisting of 0 9 and Maintenance Console Location 10 6 8 5 ...

Page 764: ...er exceptions can be programmed 40 leading number exception entries are displayed on the screen at a time To display other sets click the applicable tab Leading Number Exception Specifies the leading number exception Default Not stored Value Range Max 16 digits consisting of 0 9 and X Maintenance Console Location 10 7 8 6 Leading Number Exception Programming Manual References None Feature Manual R...

Page 765: ... display other groups click the applicable tab Authorization Code for Trunk Group TRG 01 TRG 64 Specifies the Authorization code of each carrier for each trunk group Default Not stored Value Range Max 10 digits consisting of 0 9 and Maintenance Console Location 10 8 8 7 Authorization Code for TRG Programming Manual References 10 6 8 5 Carrier Carrier Modify Command Feature Manual References 1 1 3 ...

Page 766: ...766 PC Programming Manual Document Version 2009 12 10 8 8 7 Authorization Code for TRG ...

Page 767: ...Section 11 9 Private Network Document Version 2009 12 PC Programming Manual 767 ...

Page 768: ... time To display other priority sets click the applicable tab Using a private network up to 8 PBXs can share one VPS centralized VM connected to another PBX This VPS can provide voice mail for extensions attached to any of the PBXs in the network Only extension numbers of 4 digits or less using the Extension Number Method are supported Own PBX Code Specifies the PBX code of the local PBX when usin...

Page 769: ... Maintenance Console Location 11 1 9 1 TIE Table Programming Manual References None Feature Manual References 13 1 15 PRIVATE NETWORK FEATURES Added Number Specifies the number to be added to the dialed number in place of the removed digits for each priority Default Not stored Value Range Max 32 digits consisting of 0 9 and P Pause Maintenance Console Location 11 1 9 1 TIE Table Programming Manual...

Page 770: ...Manual References 13 1 15 PRIVATE NETWORK FEATURES Centralized VM Leading Number Specifies the leading number for other PBX extension numbers or the PBX code of other PBXs in the TIE line network Default Not stored Value Range Max 3 digits consisting of 0 9 and Maintenance Console Location 11 1 9 1 TIE Table Programming Manual References None Feature Manual References 13 1 15 PRIVATE NETWORK FEATU...

Page 771: ...is attached to extensions connected to other PBXs in the network Default Enable Value Range Disable Enable Maintenance Console Location 11 1 9 1 TIE Table Programming Manual References None Feature Manual References 13 1 16 Private Network Features Centralized Voice Mail Document Version 2009 12 PC Programming Manual 771 11 1 9 1 TIE Table ...

Page 772: ...o one PBX each within a network Assigning the same Network ID to two PBXs will cause network data transmission problems Changing this value in Interactive mode will automatically clear any NDSS Link Data Default 0 Value Range 0 The PBX retransmits BLF data sent by other PBXs 1 The PBX receives BLF data sent by other PBXs 2 8 The PBX transmits BLF data over the network Maintenance Console Location ...

Page 773: ...e Location 11 2 9 2 Network Data Transmission Programming Manual References 11 3 9 3 Network Operator VoIP IP GW Card Slot No to notify BLF data to Network Operator Feature Manual References 13 1 17 Private Network Features NDSS Network Direct Station Selection Network Data Transmission for Centralized Operator Feature Data Transmission Counter Specifies the maximum number of hops or transmissions...

Page 774: ...e Feature Manual References 13 1 17 Private Network Features NDSS Network Direct Station Selection Network MSW Data Transmission for Centralized VM Feature Data Re transmission Repeat Counter Specifies the number of times re transmission of network message waiting notifications is repeated before being canceled Default 3 Value Range 0 10 Maintenance Console Location 11 2 9 2 Network Data Transmiss...

Page 775: ...otifications Default 30 s Value Range 10 240 s Maintenance Console Location 11 2 9 2 Network Data Transmission Programming Manual References 11 1 9 1 TIE Table Enhanced QSIG Call Information Activation Key Required Feature Manual References 13 1 16 Private Network Features Centralized Voice Mail Document Version 2009 12 PC Programming Manual 775 11 2 9 2 Network Data Transmission ...

Page 776: ...ension at the monitor PBX can be specified here Default Not stored Value Range Max 16 digits consisting of 0 9 and Maintenance Console Location 11 3 9 3 Network Operator VoIP Programming Manual References 11 2 9 2 Network Data Transmission Network Data Transmission for Centralized Operator Feature Network PBX ID Feature Manual References 13 1 17 Private Network Features NDSS Network Direct Station...

Page 777: ...mming Manual References None Feature Manual References 13 1 17 Private Network Features NDSS Network Direct Station Selection Document Version 2009 12 PC Programming Manual 777 11 3 9 3 Network Operator VoIP ...

Page 778: ... extension attached to another PBX that will be monitored The number input here can use either Extension Number Method or PBX Code Method Default Not stored Value Range Max 16 digits consisting of 0 9 and Maintenance Console Location 11 4 9 4 NDSS Key Table Programming Manual References None Feature Manual References 13 1 17 Private Network Features NDSS Network Direct Station Selection 13 1 15 PR...

Page 779: ...at the extension is connected to reference only Default Not stored Value Range None 1 8 Maintenance Console Location 11 4 9 4 NDSS Key Table Programming Manual References 11 2 9 2 Network Data Transmission Network Data Transmission for Centralized Operator Feature Network PBX ID Feature Manual References 13 1 17 Private Network Features NDSS Network Direct Station Selection Document Version 2009 1...

Page 780: ...780 PC Programming Manual Document Version 2009 12 11 4 9 4 NDSS Key Table ...

Page 781: ...Section 12 10 CO Incoming Call Document Version 2009 12 PC Programming Manual 781 ...

Page 782: ...cation 12 1 10 1 CO Line Settings Programming Manual References None Feature Manual References None Slot Indicates the slot position of each CO line card reference only Default Current slot number Value Range Slot number Maintenance Console Location 12 1 10 1 CO Line Settings Programming Manual References None Feature Manual References None Port Indicates the port number reference only 782 PC Prog...

Page 783: ...tension s display when receiving a call from the CO line Default Not stored Value Range Max 20 characters Maintenance Console Location 12 1 10 1 CO Line Settings Programming Manual References None Feature Manual References 4 1 9 Display Information Trunk Group Number Specifies the trunk group number to which the CO line belongs Default 1 Value Range 1 64 Document Version 2009 12 PC Programming Man...

Page 784: ...ance Console Location 12 1 10 1 CO Line Settings Programming Manual References None Feature Manual References 7 1 1 GROUP FEATURES 784 PC Programming Manual Document Version 2009 12 12 1 10 1 CO Line Settings ...

Page 785: ...eak night Generally DIL distribution is used for CO line calls from analog CO lines Tenant number and VM trunk group number can also be programmed for each CO line To assign DIL destination numbers enter directly or click Destination Setting see 2 1 6 Extension Number Setting Shelf Indicates the shelf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console L...

Page 786: ... Settings Programming Manual References None Feature Manual References None Card Type Indicates the CO line card type reference only Default Current card type Value Range Card type Maintenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References None Feature Manual References 9 1 10 INCOMING CALL FEATURES 786 PC Programming Manual Document Version 2009 12 12 2 10 2 DIL ...

Page 787: ...he value range of this setting depends on the card type and Trunk Property assigned for each CO line Default For PRI23 card DID For V IPGW card TIE Value Range DIL Distribution depends on the CO line through which the calls arrive DID Distribution depends on the DID number of the calls Maintenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References None Feature Manual ...

Page 788: ...e of day Default 1 Value Range 1 8 Maintenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References 4 6 2 4 Week Table Feature Manual References 4 1 7 DIL Direct In Line 17 1 3 Tenant Service 17 1 5 Time Service VM Trunk Group No Specifies the number of the VM trunk group sent to the VPS when the DIL destination is the floating extension number of a VM DPT Group The VM ...

Page 789: ...s if the caller s identification number is found in the System Speed Dialing Table CLI distribution can be enabled or disabled for each time mode day lunch break night on a CO line basis Shelf Indicates the shelf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References None Feature Manua...

Page 790: ...port number Value Range Port number Maintenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References None Feature Manual References None Card Type Indicates the CO line card type reference only Default Current card type Value Range Card type Maintenance Console Location 12 2 10 2 DIL Table Port Settings 790 PC Programming Manual Document Version 2009 12 12 2 10 2 DIL Ta...

Page 791: ...RES 13 1 15 PRIVATE NETWORK FEATURES Distribution Method Selects the distribution method for incoming CO line calls The value range of this setting depends on the card type and Trunk Property assigned for each CO line Default For PRI23 card DID For V IPGW card TIE Value Range DIL Distribution depends on the CO line through which the calls arrive DID Distribution depends on the DID number of the ca...

Page 792: ...ation Distribution 4 1 7 DIL Direct In Line DID TIE For each CO line to which DID distribution is set or for each CO line whose Trunk Property on this screen is Private TIE modification parameters for DID number and TIE line call numbers can be programmed Shelf Indicates the shelf type reference only Default Current shelf type Value Range Physical Virtual Maintenance Console Location 12 2 10 2 DIL...

Page 793: ...ng Manual References None Feature Manual References None Port Indicates the port number reference only Default Current port number Value Range Port number Maintenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References None Feature Manual References None Card Type Indicates the CO line card type reference only Document Version 2009 12 PC Programming Manual 793 12 2 10 ...

Page 794: ...e Location 12 2 10 2 DIL Table Port Settings Programming Manual References None Feature Manual References 9 1 10 INCOMING CALL FEATURES 13 1 15 PRIVATE NETWORK FEATURES Distribution Method Selects the distribution method for incoming CO line calls The value range of this setting depends on the card type and Trunk Property assigned for each CO line Default For PRI23 card DID For V IPGW card TIE Val...

Page 795: ...bution or for TIE line service Default 0 Value Range 0 15 Maintenance Console Location 12 2 10 2 DIL Table Port Settings Programming Manual References None Feature Manual References 4 1 6 DID Direct Inward Dialing 13 1 15 PRIVATE NETWORK FEATURES DID TIE Additional Dial Specifies the number to be added to the incoming called number in the place of the removed digits for DID distribution or for TIE...

Page 796: ... 2 DIL Table Port Settings Programming Manual References None Feature Manual References 4 1 6 DID Direct Inward Dialing 13 1 15 PRIVATE NETWORK FEATURES 796 PC Programming Manual Document Version 2009 12 12 2 10 2 DIL Table Port Settings ...

Page 797: ...mbers enter directly or click Destination Setting see 2 1 6 Extension Number Setting It is possible to program DID numbers and DID destinations in each time mode day lunch break night for a set of locations in series at once by clicking Automatic Registration or to program DID names for a set of locations in series at once by clicking Name Generate DID Number Specifies the DID number Default Not s...

Page 798: ...cation 12 3 10 3 DID Table Programming Manual References 4 9 2 6 1 Numbering Plan Main 12 4 10 3 DID Table Automatic Registration Feature Manual References 4 1 6 DID Direct Inward Dialing 13 1 15 PRIVATE NETWORK FEATURES Tenant Number Specifies the tenant number to determine the Time Table by which calls are distributed depending on the time of day Default 1 Value Range 1 8 Maintenance Console Loc...

Page 799: ...ion 12 3 10 3 DID Table Programming Manual References None Feature Manual References 4 1 6 DID Direct Inward Dialing 19 1 4 Voice Mail DPT Digital Integration CLI Ring for DID Day Lunch Break Night Enables CLI distribution in each time mode Default Disable Value Range Disable Enable Maintenance Console Location 12 3 10 3 DID Table Programming Manual References 8 1 6 1 System Speed Dial Feature Man...

Page 800: ...2 3 10 3 DID Table Feature Manual References 4 1 6 DID Direct Inward Dialing Generate DID Number From Specifies the DID number of the first location to be programmed DID numbers for subsequent locations will be generated automatically by adding one to the value of the previous location Default Not stored Value Range Max 32 digits consisting of 0 9 Maintenance Console Location 12 4 10 3 DID Table A...

Page 801: ...s to be used for all locations for a certain time mode click the appropriate Same all check box If the Same all check box for a certain time mode is not clicked the destination numbers for subsequent locations will be generated automatically by adding one to the value of the previous location for that time mode Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Locat...

Page 802: ... Maintenance Console Location 12 5 10 3 DID Table Name Generate Programming Manual References 12 3 10 3 DID Table Feature Manual References 4 1 6 DID Direct Inward Dialing Number to Generate Specifies the number of locations to be programmed Default Not stored Value Range 1 1000 Maintenance Console Location 12 5 10 3 DID Table Name Generate Programming Manual References 12 3 10 3 DID Table Feature...

Page 803: ...4 1 6 DID Direct Inward Dialing Name Prefix Specifies the text to be included at the start of each DID name Default Not stored Value Range Max 20 characters Maintenance Console Location 12 5 10 3 DID Table Name Generate Programming Manual References 12 3 10 3 DID Table Feature Manual References 4 1 6 DID Direct Inward Dialing Name Suffix Specifies the text to be included at the end of each DID nam...

Page 804: ...Console Location 12 5 10 3 DID Table Name Generate Programming Manual References 12 3 10 3 DID Table Feature Manual References 4 1 6 DID Direct Inward Dialing 804 PC Programming Manual Document Version 2009 12 12 5 10 3 DID Table Name Generate ...

Page 805: ...to the intercept destination Maintenance Console Location 12 6 10 4 Miscellaneous Programming Manual References None Feature Manual References 4 1 10 DND Do Not Disturb 9 1 11 Intercept Routing Intercept Routing to Operator No Destination Destination is not programmed Enables the Intercept Routing No Destination feature to activate when there is no destination for the call The Intercept Routing No...

Page 806: ...Intercept Routing feature to operate for extension calls Default Enable Value Range Disable Enable Maintenance Console Location 12 6 10 4 Miscellaneous Programming Manual References None Feature Manual References 9 1 12 Intercept Routing No Destination 806 PC Programming Manual Document Version 2009 12 12 6 10 4 Miscellaneous ...

Page 807: ...Section 13 11 Maintenance Document Version 2009 12 PC Programming Manual 807 ...

Page 808: ...e C 120 digits Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording SMDR Format Port Selects the Serial Interface port that is used to output the SMDR data Default RS 232C Value Range None LAN RS 232C Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual Referenc...

Page 809: ...il Recording SMDR Format Blank Footer Length Number of Lines Specifies the number of lines to be skipped at the end of every page The number of lines for the skip perforation should be shorter than the page length Default 0 Value Range 0 95 Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording SMDR Form...

Page 810: ...ault 12H Value Range 12H 24H Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording Print Information Outgoing Call Specifies whether the dialed digits of outgoing CO line calls are printed Class of Service COS programming determines the printable records Default Print Value Range No Print Print Maintena...

Page 811: ...o Print Value Range No Print Print Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording Print Information Intercom Call Specifies whether the dialed digits of outgoing intercom calls are printed Default No Print Value Range No Print Print Maintenance Console Location 13 1 11 1 Main Programming Manual R...

Page 812: ...l Recording Print Information Hotel Room Status Selects whether check in and check out data is output on SMDR Default No Print Value Range No Print Print Maintenance Console Location 13 1 11 1 Main Programming Manual References 8 2 6 2 Hotel Feature Manual References 16 1 3 SMDR Station Message Detail Recording 15 1 3 Room Status Control Print Information Error Log Specifies whether PBX error log ...

Page 813: ... Modification The user dialed number Dial after ARS Modification The ARS modified number Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 1 1 3 ARS Automatic Route Selection 8 1 5 Host PBX Access Code Access Code to the Telephone Company from a Host PBX 16 1 3 SMDR Station Message Detail Recording Option Caller ID Number Name Selects the prin...

Page 814: ...ces None Feature Manual References 16 1 3 SMDR Station Message Detail Recording Option Secret Dial Selects the printing format of calls with a secret dial The secret dial conceals all or part of the dialed number Note that selecting Dial before ARS Modification in Option ARS Dial on this screen indicates the dialed numbers as dots regardless of this setting Default Print Secret Value Range Print S...

Page 815: ... 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording Option Condition Code AN VA Specifies whether the time of answering an incoming CO line call is printed Default No Print Value Range No Print Print Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message ...

Page 816: ...ller ID Modification Feature Manual References 16 1 3 SMDR Station Message Detail Recording LAN SMDR Port Number Specifies the port number used to output SMDR data via the LAN Default 2300 Value Range 1 65535 Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording LAN SMDR Password Specifies the password ...

Page 817: ...fault CR LF Value Range CR LF CR Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording RS 232C Communication Baud Rate Specifies the data transmission speed from the PBX to the printer or personal computer To ensure stable transmission when changing this setting to 57600 or 115200 bps set Communication ...

Page 818: ... Line Feed Default CR LF Value Range CR LF CR Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording Communication Parity Bit Selects a parity bit code that indicates what type of parity is used to detect an error in the string of bits composing a character Make an appropriate selection depending on the ...

Page 819: ...it Notice Do not use the following combinations Word Length 8 bit Parity Bit Space Stop Bit 1 bit Word Length 8 bit Parity Bit Mark Stop Bit 2 bit Word Length 8 bit Parity Bit Space Stop Bit 2 bit Default 8 bit Value Range 7 bit 8 bit Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording Communication F...

Page 820: ...1 Main Programming Manual References None Feature Manual References 16 1 3 SMDR Station Message Detail Recording External Modem Command Automatic Initialization Specifies the command to automatically initialize an external modem when it is plugged into the Serial Interface RS 232C port of the PBX Default AT F0Q0E0V1S0 1X0 D0 Value Range Max 30 characters Maintenance Console Location 13 1 11 1 Main...

Page 821: ...sion 2 Specifies the extension numbers of PTs that will be notified by the PBX about local alarms When the PBX detects a PBX error the System Alarm button on the PT turns on red When this button is pressed the display will show the error number and the button light will turn off automatically Default Not stored Value Range Max 5 digits consisting of 0 9 Maintenance Console Location 13 1 11 1 Main ...

Page 822: ...ur Specifies the hour of the PBX daily self check start time Default 0 Value Range 0 23 Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 10 1 4 Local Alarm Information Daily Test Start Time Minute Specifies the minute of the PBX daily self check start time Default 0 Value Range 0 59 822 PC Programming Manual Document Version 2009 12 13 1 11 1...

Page 823: ...ble Maintenance Console Location 13 1 11 1 Main Programming Manual References 11 1 9 1 TIE Table Enhanced QSIG Call Information Activation Key Required 11 2 9 2 Network Data Transmission Network MSW Data Transmission for Centralized VM Feature Data Re transmission Repeat Counter Feature Manual References 13 1 16 Private Network Features Centralized Voice Mail Error Log for Centralized VM Network M...

Page 824: ... Range Disable Enable Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 9 Syslog Record Management Syslog Syslog Server IP Address Specifies the IP address of a syslog server Default Not stored Value Range 1 0 0 0 223 255 255 255 Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 ...

Page 825: ...on to a syslog server Default Enable Value Range Disable Enable Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 16 1 9 Syslog Record Management Remote Remote Analog Remote Modem Floating Extension Number Specifies the floating extension number for analog remote maintenance To enable this setting an RMT card must be installed and Remote Remot...

Page 826: ...ion Default Enable Value Range Disable Enable Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 13 1 6 PC Programming Remote Password Lock Counter for Remote Programming Specifies the number of successive incorrect password entries allowed before remote access is locked Default None Value Range None 1 15 Maintenance Console Location 13 1 11 1 ...

Page 827: ...of 0 9 and Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 14 1 2 Quick Setup Password Passwords authorize the user to program the extension and the PBX by a PT or a personal computer System Password PT Programming Prog User Level Specifies the user level system password to authorize the PT user to access only the permitted system programmin...

Page 828: ... Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 13 1 30 PT Programming Manager Password PT Programming Prog 1 Specifies the manager password to authorize the PT user to access manager programming Default 1234 Value Range 4 10 digits consisting of 0 9 and Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature ...

Page 829: ...ing Administrator Level Specifies the system password used to access Maintenance Console at Administrator Level Default 1234 Value Range 4 10 characters Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 13 1 6 PC Programming System Password PC Programming Installer Level Specifies the system password used to access Maintenance Console at Insta...

Page 830: ...Maintenance Console Location 13 1 11 1 Main Programming Manual References None Feature Manual References 13 1 6 PC Programming 830 PC Programming Manual Document Version 2009 12 13 1 11 1 Main ...

Page 831: ...e 000 999 Maintenance Console Location 13 2 11 2 PT Programming Access Programming Manual References None Feature Manual References 13 1 30 PT Programming PROG Selects whether User Level PT users can access each system programming item Default 000 009 020 099 Enable 010 019 100 999 Disable Value Range Disable Enable Maintenance Console Location 13 2 11 2 PT Programming Access Programming Manual Re...

Page 832: ...e CO line card to be used Default None Value Range None Small Free Slot 1 Small Free Slot 2 Small Free Slot 3 Small Free Slot 4 KX NCP1000 only Maintenance Console Location 13 3 11 3 Power Failure Transfer Programming Manual References None Feature Manual References 13 1 11 Power Failure Transfer Extension Card Slot No Specifies the position of the extension card to be used Default None Value Rang...

Page 833: ...ble Value Range Disable Enable Maintenance Console Location 13 4 11 4 1 SNMP System Setting Programming Manual References None Feature Manual References 16 1 4 SNMP Simple Network Management Protocol System Monitor Port Number Receive Specifies the port number used to receive SNMP data requests from an SNMP manager Default 161 Value Range 1 65535 Maintenance Console Location 13 4 11 4 1 SNMP Syste...

Page 834: ...l System Monitor MIB SysName Specifies an administrative name for the system Default Not stored Value Range Max 255 characters Maintenance Console Location 13 4 11 4 1 SNMP System Setting Programming Manual References None Feature Manual References 16 1 4 SNMP Simple Network Management Protocol System Monitor MIB SysLocation Specifies a physical location for the system Default Not stored Value Ran...

Page 835: ...4 11 4 1 SNMP System Setting Programming Manual References None Feature Manual References 16 1 4 SNMP Simple Network Management Protocol System Monitor Document Version 2009 12 PC Programming Manual 835 13 4 11 4 1 SNMP System Setting ...

Page 836: ...0 0 223 255 255 255 Maintenance Console Location 13 5 11 4 2 SNMP Manager Programming Manual References None Feature Manual References 16 1 4 SNMP Simple Network Management Protocol System Monitor Community Name Specifies a community name of an SNMP manager Default public Value Range Max 255 characters Maintenance Console Location 13 5 11 4 2 SNMP Manager Programming Manual References None Feature...

Page 837: ...ts whether the PBX sends Cold Start TRAP to an SNMP manager or not Default Enable Value Range Disable Enable Maintenance Console Location 13 5 11 4 2 SNMP Manager Programming Manual References None Feature Manual References 16 1 4 SNMP Simple Network Management Protocol System Monitor TRAP Authentication Failure Selects whether the PBX sends Authentication Failure TRAP to an SNMP manager or not De...

Page 838: ...nge Disable Enable Maintenance Console Location 13 5 11 4 2 SNMP Manager Programming Manual References None Feature Manual References 16 1 4 SNMP Simple Network Management Protocol System Monitor TRAP Alarm Minor Selects whether the PBX sends Minor Alarm TRAP to an SNMP manager or not Default Enable Value Range Disable Enable Maintenance Console Location 13 5 11 4 2 SNMP Manager Programming Manual...

Page 839: ...Feature Manual References 16 1 4 SNMP Simple Network Management Protocol System Monitor Document Version 2009 12 PC Programming Manual 839 13 5 11 4 2 SNMP Manager ...

Page 840: ... 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization Group Feature Manual References None Slot Type Indicates the slot type reference only Default Current slot type Value Range Physical Virtual Maintenance Console Location 13 6 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization Group Feature Manual References None Slot Indicates th...

Page 841: ...the port number reference only Default Current port number Value Range Port number Maintenance Console Location 13 6 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization Group Feature Manual References None CS Name Indicates the name of the CS reference only Default Not applicable Value Range Max 20 characters Document Version 2009 12 PC Programming Manual 841 13 6 ...

Page 842: ...lue Range INS The port is in service OUS The port is out of service Fault The port is not communicating with the network Maintenance Console Location 13 6 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization Group Feature Manual References None Status Indicates whether a certain CS is registered reference only Default Not applicable Value Range Registered Maintenanc...

Page 843: ...ync Master CS2 Sync Slave CS Maintenance Console Location 13 6 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization Group Feature Manual References None Primary CS Index Specifies the number of the primary CS Default Not applicable Value Range 1 16 Maintenance Console Location 13 6 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization ...

Page 844: ...Primary CS Port Indicates the port number of the primary CS reference only Default Current port number Value Range Port number Maintenance Console Location 13 6 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization Group Feature Manual References None Primary CS CS Name Indicates the name of the primary CS reference only Default Not applicable Value Range Max 20 char...

Page 845: ...e Location 13 6 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization Group Feature Manual References None Secondary CS Slot Indicates the slot position of the secondary CS reference only Default Current slot number Value Range Slot number Maintenance Console Location 13 6 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization Group Docu...

Page 846: ...References 5 26 3 10 Air Synchronization Group Feature Manual References None Secondary CS CS Name Indicates the name of the secondary CS reference only Default Not applicable Value Range Max 20 characters Maintenance Console Location 13 6 11 5 Air Synchronization Programming Manual References 5 26 3 10 Air Synchronization Group Feature Manual References None 846 PC Programming Manual Document Ver...

Page 847: ...Section 14 Appendix Document Version 2009 12 PC Programming Manual 847 ...

Page 848: ... 1 1 1 Slot To access IP PT port properties Changed Contents 1 2 1 Installing and Starting the Maintenance Console 3 15 1 1 Slot Port Property Virtual IP Extension 3 39 1 2 Portable Station 848 PC Programming Manual Document Version 2009 12 14 1 1 KX NCP500 KX NCP1000 PBMPR Software File Version 1 01xx ...

Page 849: ...sic Source of BGM2 7 OGM No BGM and Music on Hold Music Source of BGM2 7 Card 4 5 2 3 Timers Counters Miscellaneous Air Synchronization Watching Degeneracy 5 26 3 10 Air Synchronization Group 13 6 11 5 Air Synchronization Changed Contents 1 2 1 Installing and Starting the Maintenance Console PBX Web Manager 2 6 6 Utility Message File Transfer PC to PBX 2 6 7 Utility Message File Transfer PBX to PC...

Page 850: ...igit Dial Extension Inter digit 4 18 2 9 System Options 6 1 4 1 1 Wired Extension Extension Settings 6 3 4 1 2 Wired Extension FWD DND 6 10 4 2 1 Portable Station Extension Settings Maximum length of extension number 6 12 4 2 2 Portable Station FWD DND 8 6 6 6 Tenant Music On Hold 11 1 9 1 TIE Table 12 1 10 1 CO Line Settings 850 PC Programming Manual Document Version 2009 12 14 1 2 KX NCP500 KX N...

Page 851: ...uting Plan 2 5 9 Tool Export 4 5 2 3 Timers Counters Dial IRNA Recall Tone Dial Extension Inter digit 4 18 2 9 System Options Option 3 Dial Tone Dial Tone for ARS 6 1 4 1 1 Wired Extension Extension Settings Option 1 ARS Itemized Code 6 10 4 2 1 Portable Station Extension Settings Option 1 ARS Itemized Code 8 3 6 3 Verification Code Itemized Billing Code for ARS Section 10 8 ARS 13 1 11 1 Main SMD...

Page 852: ... BGM 4 9 2 6 1 Numbering Plan Main Features External BGM On Off BGM Set Cancel 4 20 2 11 1 Audio Gain Paging MOH MOH MOH Music On Hold 7 2 5 2 External Pager Feature Manual References 2 1 1 BGM Background Music C Caller ID 4 4 2 2 Operator BGM Caller ID Waiting to receive Caller ID Visual Caller ID Display 4 18 2 9 System Options Option 4 Private Network Public Call through Private Network Minimum...

Page 853: ...ngs Group Log Group FWD Supervisor Extension Number 6 1 4 1 1 Wired Extension Extension Settings Option 5 Incoming Call Display Option 6 Display Lock SVM Lock Option 7 Incoming Call Log Memory 6 5 4 1 4 Wired Extension Flexible Button Type 6 10 4 2 1 Portable Station Extension Settings Option 5 Incoming Call Display Option 7 Incoming Call Log Memory 6 17 4 3 DSS Console Type Feature Manual Referen...

Page 854: ...9 2 6 1 Numbering Plan Main Features Group Call Pickup Directed Call Pickup Call Pickup Deny Set Cancel 4 12 2 7 1 Class of Service COS Settings CO SMDR Call Pickup by DSS 4 18 2 9 System Options Option 4 DSS Key DSS key mode for Incoming Call DSS Key Call Pick up by DSS key for Direct Incoming Call DSS Key Call Pick up by DSS key for ICD Group Call 5 7 3 3 Call Pickup Group 6 1 4 1 1 Wired Extens...

Page 855: ...nsion Settings Option 2 Manual C Waiting for Extension Call Option 2 Automatic C Waiting Option 4 Call Waiting Tone Type 6 10 4 2 1 Portable Station Extension Settings Option 2 Manual C Waiting for Extension Call Option 2 Automatic C Waiting Option 4 Call Waiting Tone Type Feature Manual References 3 1 11 CALL WAITING FEATURES Call Waiting Tone 4 5 2 3 Timers Counters Miscellaneous Caller ID Visua...

Page 856: ... 4 18 2 9 System Options Option 4 Send CLIP of CO Caller to ISDN when Transfer CLIP of Held Party 5 12 3 5 1 Incoming Call Distribution Group Group Settings Main CLIP on G DN Button 6 1 4 1 1 Wired Extension Extension Settings Main Extension Number ISDN CLIP CLIP ID ISDN CLIP CLIP on Extension CO ISDN CLIP CLIR ISDN CLIP COLR 6 5 4 1 4 Wired Extension Flexible Button Type 6 10 4 2 1 Portable Stati...

Page 857: ...ual References 3 1 16 CO Line Access CO Line Call Limitation 4 12 2 7 1 Class of Service COS Settings CO SMDR Extension CO Line Call Duration Limit 4 18 2 9 System Options Option 2 Extension CO Call Limitation For Incoming Call 5 1 3 1 1 Trunk Group TRG Settings Main CO CO Duration Time 60s Extension CO Duration Time 60s 9 5 7 5 Miscellaneous Dial Digits Limitation After Answering Dial Digits Feat...

Page 858: ... Confirmation Tone COS Class of Service 4 12 2 7 1 Class of Service COS Settings 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS Feature Manual References 3 1 21 COS Class of Service CPC Calling Party Control Signal Detection 3 28 1 1 Slot Port Property LCO Port CPC Signal Detection Time Outgoing Incoming 3 34 1 1 Slot Port Property T1 ...

Page 859: ...rty T1 Port CO Dial Mode DTMF Width CO Pulse Speed Feature Manual References 4 1 3 Dial Mode Selection Dial Tone 4 18 2 9 System Options Option 3 Dial Tone Distinctive Dial Tone Dial Tone Dial Tone for Extension Dial Tone Dial Tone for ARS Feature Manual References 4 1 4 Dial Tone Dial Tone Transfer 6 5 4 1 4 Wired Extension Flexible Button Type Parameter Selection for TRS Level Change 6 13 4 2 3 ...

Page 860: ...t Inward Dialing DIL Direct In Line 12 2 10 2 DIL Table Port Settings DIL DIL Destination Day Lunch Break Night Tenant Number VM Trunk Group No Feature Manual References 4 1 7 DIL Direct In Line DISA Direct Inward System Access 4 5 2 3 Timers Counters DISA Door Reminder U Conf DISA Delayed Answer Timer DISA Mute OGM Start Timer after answering DISA No Dial Intercept Timer DISA 2nd Dial Timer for A...

Page 861: ...ination Day Lunch Break Night CLI for DIL CLI Ring for DIL Day Lunch Break Night Feature Manual References 4 1 8 DISA Direct Inward System Access Display Information 4 18 2 9 System Options Option 5 PT Feature Access No 1 8 6 1 4 1 1 Wired Extension Extension Settings Option 5 Display Language Incoming Call Display Automatic LCD Switch when Start Talking 6 10 4 2 1 Portable Station Extension Setti...

Page 862: ...ons Option 3 Confirmation Tone Tone 1 Called by Voice 7 1 5 1 Doorphone Feature Manual References 4 1 12 Doorphone Call E EFA External Feature Access 3 28 1 1 Slot Port Property LCO Port Flash Time 3 34 1 1 Slot Port Property T1 Port Flash Time 4 9 2 6 1 Numbering Plan Main Features External Feature Access 6 1 4 1 1 Wired Extension Extension Settings Option 7 Flash Mode during CO Conversation 6 5 ...

Page 863: ...f Remote Extension Dial Lock On 4 12 2 7 1 Class of Service COS Settings TRS TRS Level on Extension Lock Feature Manual References 5 1 4 Extension Dial Lock Extension Feature Clear 4 9 2 6 1 Numbering Plan Main Features Extension Feature Clear 4 18 2 9 System Options Option 2 Extension Clear Call Waiting Extension Clear Fwd DND Extension Clear Hot Line Pickup Dial Feature Manual References 5 1 5 E...

Page 864: ...nal Detection Reopening Time 4 5 2 3 Timers Counters Miscellaneous External Sensor Ring Duration 4 17 2 8 3 Ring Tone Patterns Call from Others External Sensor Ring Tone Pattern Plan 1 8 7 7 5 5 External Sensor Feature Manual References 5 1 9 External Sensor F Flash Recall Terminate 3 28 1 1 Slot Port Property LCO Port Disconnect Time 3 34 1 1 Slot Port Property T1 Port Disconnect Time 6 1 4 1 1 W...

Page 865: ... 4 Flexible Numbering Fixed Numbering Floating Extension 4 9 2 6 1 Numbering Plan Main Extension 5 12 3 5 1 Incoming Call Distribution Group Group Settings Main Floating Extension Number Group Name 5 19 3 7 2 VM DPT Group Unit Settings Floating Extension No 5 22 3 8 2 VM DTMF Group Group Settings Floating Ext No 5 24 3 9 PS Ring Group Floating Extension Number 7 2 5 2 External Pager Page Number 1 ...

Page 866: ...l from Extension 4 18 2 9 System Options Option 1 PT Fwd DND Fwd LED PT Fwd DND DND LED PT Fwd DND Fwd DND key mode when Idle 6 1 4 1 1 Wired Extension Extension Settings FWD DND 6 5 4 1 4 Wired Extension Flexible Button Type Ext No Floating Ext No for Group Fwd Both Ext No Floating Ext No for Group Fwd External Ext No Floating Ext No for Group Fwd Internal 6 10 4 2 1 Portable Station Extension Se...

Page 867: ...swer Feature Manual References 8 1 1 Hands free Answerback Hands free Operation 4 5 2 3 Timers Counters Dial IRNA Recall Tone Tone Length Reorder Tone for PT Hands free 6 1 4 1 1 Wired Extension Extension Settings Option 4 LCS Answer Mode Feature Manual References 8 1 2 Hands free Operation Headset Operation 3 24 1 1 Slot Port Property Extension Port Headset OFF ON 6 5 4 1 4 Wired Extension Flexib...

Page 868: ...ard Set 5 12 3 5 1 Incoming Call Distribution Group Group Settings Main Overflow Queuing Busy Overflow No Answer Miscellaneous 5 15 3 5 3 Incoming Call Distribution Group Miscellaneous 5 13 3 5 1 Incoming Call Distribution Group Group Settings Member List Feature Manual References 9 1 1 ICD GROUP FEATURES ICD Group Features Group Call Distribution 5 1 3 1 1 Trunk Group TRG Settings Main Line Hunti...

Page 869: ... Selection for Log in Log out Ext No Floating Ext No for Log in Log out 6 10 4 2 1 Portable Station Extension Settings Option 8 Wrap up Timer 6 13 4 2 3 Portable Station Flexible Button Type Parameter Selection for Log in Log out Ext No Floating Ext No for Log in Log out 6 17 4 3 DSS Console Type Parameter Selection for Log in Log out Ext No Floating Ext No for Log in Log out 13 1 11 1 Main SMDR P...

Page 870: ...scellaneous Extension No Answer Redirection Time Miscellaneous Maximum No of Busy Extension 5 14 3 5 2 Incoming Call Distribution Group Queuing Time Table 5 18 3 7 1 VM DPT Group System Settings Call Waiting on VM Group 5 21 3 8 1 VM DTMF Group System Settings Others Call Waiting on VM Group 6 5 4 1 4 Wired Extension Flexible Button Type Ext No Floating Ext No for Hurry up 6 13 4 2 3 Portable Stat...

Page 871: ...rences 9 1 10 INCOMING CALL FEATURES Intercept Routing 4 5 2 3 Timers Counters Dial IRNA Recall Tone Intercept Routing No Answer IRNA Day Lunch Break Night 4 5 2 3 Timers Counters DISA Door Reminder U Conf DISA Intercept Timer Day Lunch Break Night 5 12 3 5 1 Incoming Call Distribution Group Group Settings Overflow No Answer Time out Manual Queue Redirection Destination Day Lunch Break Night 6 1 4...

Page 872: ...nternal Call Block 4 14 2 7 3 Class of Service Internal Call Block COS Number of the Extension Which Receive the Call from Other Extension 1 64 5 12 3 5 1 Incoming Call Distribution Group Group Settings Main COS 6 1 4 1 1 Wired Extension Extension Settings Main COS 6 10 4 2 1 Portable Station Extension Settings Main COS 7 1 5 1 Doorphone COS 7 6 5 4 External Relay COS Number Feature Manual Referen...

Page 873: ...ode for Incoming Call Feature Manual References 10 1 1 LED Indication Line Preference Incoming 6 1 4 1 1 Wired Extension Extension Settings Option 4 Incoming Preferred Line 6 10 4 2 1 Portable Station Extension Settings Option 4 Incoming Preferred Line Feature Manual References 10 1 2 Line Preference Incoming Line Preference Outgoing 4 13 2 7 2 Class of Service External Call Block 5 2 3 1 2 Trunk ...

Page 874: ...Waiting 4 9 2 6 1 Numbering Plan Main Features Message Waiting Set Cancel Call Back 4 11 2 6 3 Numbering Plan B NA DND Call Feature Message Waiting Set 4 18 2 9 System Options Option 3 Dial Tone Distinctive Dial Tone 5 21 3 8 1 VM DTMF Group System Settings VM DTMF Command Listening Message 6 5 4 1 4 Wired Extension Flexible Button Type 6 13 4 2 3 Portable Station Flexible Button Type 6 17 4 3 DSS...

Page 875: ...oup Group Settings Member List Delayed Ring Feature Manual References 12 1 2 OGM Outgoing Message OHCA Off hook Call Announcement 4 11 2 6 3 Numbering Plan B NA DND Call Feature BSS OHCA Whisper OHCA DND Override BSS OHCA Whisper OHCA DND Override 2 4 12 2 7 1 Class of Service COS Settings CO SMDR OHCA Whisper OHCA Feature Manual References 12 1 3 OHCA Off hook Call Announcement One touch Dialing ...

Page 876: ...Paging EPG External Pager Paging Paging Level from PT Speaker 5 9 3 4 Paging Group 5 10 3 4 Paging Group All Setting 5 11 3 4 Paging Group External Pager 6 1 4 1 1 Wired Extension Extension Settings Option 6 Paging Deny Feature Manual References 13 1 1 Paging Paralleled Telephone 3 23 1 1 Slot Card Property Extension Type APT SLT Parallel Ring 3 24 1 1 Slot Port Property Extension Port XDP Mode Pa...

Page 877: ...d PC Programming User Level Password System Password PC Programming Administrator Level Password System Password PC Programming Installer Level Feature Manual References 13 1 6 PC Programming PDN Primary Directory Number SDN Secondary Directory Number Extension 4 12 2 7 1 Class of Service COS Settings PDN SDN 4 18 2 9 System Options Option 4 System Wireless SDN Delayed Ringing with LCD 6 5 4 1 4 W...

Page 878: ...es 13 1 11 Power Failure Transfer Printing Message 4 9 2 6 1 Numbering Plan Main Features Printing Message 8 2 6 2 Hotel Main SMDR for External Hotel Application 2 Printing Message 1 8 Feature Manual References 13 1 13 Printing Message Privacy Release 4 18 2 9 System Options Option 1 PT Operation Privacy Release by SCO key 6 5 4 1 4 Wired Extension Flexible Button Type 6 13 4 2 3 Portable Station ...

Page 879: ... Private Network Features Centralized Voice Mail 3 40 1 3 Option New Card Installation ISDN Standard Mode for PRI23 Card 11 1 9 1 TIE Table Centralized VM 11 2 9 2 Network Data Transmission Network MSW Data Transmission for Centralized VM Feature Data Re transmission Repeat Counter Network MSW Data Transmission for Centralized VM Feature Data Re transmission Repeat Timer 13 1 11 1 Main Maintenance...

Page 880: ... Timer 4 18 2 9 System Options Option 4 System Wireless Out of Range Registration Feature Manual References 13 1 19 Private Network Features PS Roaming by Network ICD Group Private Network Features QSIG 3 31 1 1 Slot Port Property PRI Port Supplementary Service COLP CLIR COLR CNIP CONP CNIR CONR CF Rerouting CT CCBS E911 4 9 2 6 1 Numbering Plan Main Features COLR Set Cancel CLIR Set Cancel 6 1 4 ...

Page 881: ...CONP Calling Connected Name Identification Presentation 3 31 1 1 Slot Port Property PRI Port Supplementary Service COLP CLIR COLR CNIP CONP CNIR CONR CF Rerouting CT CCBS E911 4 9 2 6 1 Numbering Plan Main Features COLR Set Cancel CLIR Set Cancel 6 1 4 1 1 Wired Extension Extension Settings Main Extension Number Extension Name 6 10 4 2 1 Portable Station Extension Settings Main Extension Number Ex...

Page 882: ...Number Telephone Number Feature Manual References 13 1 27 PS Directory PS Ring Group 5 12 3 5 1 Incoming Call Distribution Group Group Settings Main Distribution Method 5 24 3 9 PS Ring Group 5 25 3 9 PS Ring Group Member List Feature Manual References 13 1 29 PS Ring Group PT Programming 4 12 2 7 1 Class of Service COS Settings Programming Manager Programming Mode Level 13 1 11 1 Main Password Sy...

Page 883: ...ture Manual References 15 1 1 Redial Last Number Ring Tone Pattern Selection 4 15 2 8 1 Ring Tone Patterns Call from CO Ring Tone Pattern Plan 1 8 4 16 2 8 2 Ring Tone Patterns Call from Doorphone Ring Tone Pattern Plan 1 8 4 17 2 8 3 Ring Tone Patterns Call from Others Extension Ring Tone Pattern Plan 1 8 4 18 2 9 System Options Option 1 PT Operation PT Ring Off Setting 6 1 4 1 1 Wired Extension ...

Page 884: ...ager Feature Manual References 16 1 4 SNMP Simple Network Management Protocol System Monitor SMDR Station Message Detail Recording 4 5 2 3 Timers Counters Dial IRNA Recall Tone Dial Analog CO Call Duration Start 4 12 2 7 1 Class of Service COS Settings CO SMDR Outgoing CO Call Printout SMDR 8 2 6 2 Hotel Main SMDR for External Hotel Application 2 Printing Message 1 8 13 1 11 1 Main SMDR SMDR Optio...

Page 885: ...ol Simplified Voice Message Delete All Recording 2 5 5 Tool Simplified Voice Message Check Current Usage 4 5 2 3 Timers Counters Miscellaneous SVM Recording Time SVM Dial Tone Continuous Time 4 9 2 6 1 Numbering Plan Main Features Simplified Voice Message Access 5 1 3 1 1 Trunk Group TRG Settings Tone Detection Simplified Voice Message Tone Detection Silence Simplified Voice Message Tone Detection...

Page 886: ...ht BGM and Music on Hold Music on Hold 4 6 2 4 Week Table 4 8 2 5 Holiday Table 4 14 2 7 3 Class of Service Internal Call Block 5 6 3 2 Extension Group 5 12 3 5 1 Incoming Call Distribution Group Group Settings Main Tenant Number 6 1 4 1 1 Wired Extension Extension Settings Main Extension Group 6 10 4 2 1 Portable Station Extension Settings Main Extension Group 7 1 5 1 Doorphone Tenant Number 7 7 ...

Page 887: ... Settings Programming Manager Time Service Switch 6 5 4 1 4 Wired Extension Flexible Button Type Parameter Selection for Time Service Parameter Selection for Time Service Automatic Manual Optional Parameter Ringing Tone Type Number for Time Service 6 13 4 2 3 Portable Station Flexible Button Type Parameter Selection for Time Service Parameter Selection for Time Service Automatic Manual Optional Pa...

Page 888: ...ity File Transfer PC to PBX SD Card Feature Manual References 18 1 1 Upgrading the Software V Verification Code Entry 4 5 2 3 Timers Counters Miscellaneous Extension PIN Lock Counter 4 9 2 6 1 Numbering Plan Main Features User Remote Operation Walking COS Verification Code 6 1 4 1 1 Wired Extension Extension Settings Option 1 ARS Itemized Code 6 10 4 2 1 Portable Station Extension Settings Option ...

Page 889: ...1 4 Wired Extension Flexible Button Type Ext No Floating Ext No for Two way Record Ext No Floating Ext No for Two way Transfer Ext No Floating Ext No for Voice Mail Transfer Ext No of Mailbox for Two way Transfer 6 10 4 2 1 Portable Station Extension Settings Option 4 LCS Recording Mode 6 13 4 2 3 Portable Station Flexible Button Type Ext No Floating Ext No for Two way Record Ext No Floating Ext N...

Page 890: ...n Flexible Button Type Ext No Floating Ext No for Voice Mail Transfer 6 17 4 3 DSS Console Type Ext No Floating Ext No for Voice Mail Transfer Feature Manual References 19 1 5 Voice Mail DTMF Integration W Walking COS 4 9 2 6 1 Numbering Plan Main Features User Remote Operation Walking COS Verification Code 4 12 2 7 1 Class of Service COS Settings Optional Device Other Extensions Remote Operation ...

Page 891: ...isper OHCA Wireless XDP Parallel Mode 3 24 1 1 Slot Port Property Extension Port DPT Type Type 3 39 1 2 Portable Station PS Registration and De registration 4 9 2 6 1 Numbering Plan Main Features Wireless XDP Parallel Mode Set Cancel 4 12 2 7 1 Class of Service COS Settings Optional Device Other Extensions Accept Wireless XDP Parallel Mode Set by PS 6 1 4 1 1 Wired Extension Extension Settings Opt...

Page 892: ...erial is copyrighted by Panasonic System Networks Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the written consent of Panasonic System Networks Co Ltd Panasonic System Networks Co Ltd 2009 PSQX4745XA KK0908GJ2129 v0 008 ...

Reviews: