4
3: One flash mode
3
External switch
type
1
1-3
1
1 : One switch mode
2 : Two switch mode
3: Up/Down switch
mode
4
Restore dimmer
state
1
0-2
1
0 : Dimmer off
1 : Last dimmer state
2 : Dimmer on
3-1 Dimmer level report mode :
Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_
REPORT to the nodes of group1. The default setting is Enable the function.
3-2 LED indication mode :
3-2-1 Show dimmer State
:
When dimmer is on, LED is on. When dimmer is off,
LED is off. The default setting is Show dimmer State.
3-2-2 Show Night mode
:
When dimmer is on, LED is off. When dimmer is off, LED
is on.
3-2-3 One flash mode
:
When dimmer on/off state changes, LED will light on one
second and then off.
3-3 External switch type
:
3-3-1 One switch mode
:
Only S1 can dim up the light bulb to brightest level, then
dim down to darkest level, and so on
…
3-3-2 Two switch mode
:
S1 and S2 can dim up the light bulb to brightest level, then
dim down to darkest level, and so on
…
3-3-3 Up/Down switch mode
:
S1 can only dim up the light bulb to brightest level,
and S2 can only dim down to Off.
3-4 restore dimmer state :
Whenever the AC power return from lost, PAD07 will restore the switch state which
could be Dimmer off
、
Last dimmer state
、
Dimmer on. The default setting is Last
dimmer state.
4. Firmware update over the air (OTA)
PAD07 is based on 500 series SoC and supports Firmware Update Command
Class, it can receives the updated firmware image sent by controller via the
Z-wave RF media. It is a helpful and convenient way to improve some function if
needed.
1. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_ZWAVEPLUS_INFO
* COMMAND_CLASS_VERSION_V2
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_SECURITY
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_MULTILEVEL_V2
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_ALARM
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
* COMMAND_CLASS_SCENE_ACTIVATION
* COMMAND_CLASS_SCENE_ACTUATOR_CONF
Troubleshooting
Symptom
Cause of Failure
Recommendation
The dimmer does not
work and LED off
1.The dimmer does not
connect the electrical wire
properly
2.The dimmer break down
1. Check power connections
2. Don’t open up the dimmer and send it for
repair.