background image

 

3: One flash mode

 

3

 

External switch 
type

 

1

 

1-3

 

 

1

 

1 : One switch mode 

2 : Two switch mode 

3: Up/Down switch 

mode

 

4

 

Restore dimmer 
state

 

1

 

0-2

 

 

1

 

0 : Dimmer off 

1 : Last dimmer state 

2 : Dimmer on

 

 

3-1 Dimmer level report mode : 

        Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_ 

REPORT to the nodes of group1. The default setting is Enable the function. 

3-2 LED indication mode : 

  3-2-1 Show  dimmer State

When dimmer is on, LED is on. When  dimmer is off, 

LED is off. The default setting is Show dimmer State. 

  3-2-2 Show Night mode

When dimmer is on, LED is off. When dimmer is off, LED 

is on. 

3-2-3 One flash mode

When dimmer on/off state changes, LED will light on one 

second and then off. 

3-3 External switch type

 

  3-3-1 One switch mode

Only S1 can dim up the light bulb to brightest level, then 

dim down to darkest level, and so on

…   

3-3-2 Two switch mode

S1 and S2 can dim up the light bulb to brightest level, then 

dim down to darkest level, and so on

… 

3-3-3 Up/Down switch mode

S1 can only dim up the light bulb to brightest level, 

and S2 can only dim down to Off. 

3-4 restore dimmer state : 

  Whenever the AC power return from lost, PAD07 will restore the switch state which 

could be Dimmer off

Last dimmer state

Dimmer on. The default setting is Last 

dimmer state. 

 

4. Firmware update over the air (OTA)

 

PAD07 is based on 500 series SoC and supports Firmware Update Command 

Class, it can receives the updated firmware image sent by controller via the 

Z-wave RF media. It is a helpful and convenient way to improve some function if 

needed. 

 

1.  Command Classes

 

The Switch supports Command Classes including… 

* COMMAND_CLASS_ZWAVEPLUS_INFO 

* COMMAND_CLASS_VERSION_V2 

* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 

* COMMAND_CLASS_SECURITY 

* COMMAND_CLASS_DEVICE_RESET_LOCALLY 

* COMMAND_CLASS_ASSOCIATION_V2 

* COMMAND_CLASS_ASSOCIATION_GRP_INFO 

* COMMAND_CLASS_POWERLEVEL 

* COMMAND_CLASS_BASIC 

* COMMAND_CLASS_SWITCH_MULTILEVEL_V2 

* COMMAND_CLASS_CONFIGURATION   

* COMMAND_CLASS_ALARM 

* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 

* COMMAND_CLASS_SCENE_ACTIVATION 

* COMMAND_CLASS_SCENE_ACTUATOR_CONF 

 

 

Troubleshooting

               

                   

 

Symptom

 

Cause of Failure

 

Recommendation

 

The dimmer does not 
work and LED off

 

1.The dimmer does not 

connect the electrical wire 
properly 

2.The dimmer break down

 

1.  Check power connections 
2. Don’t open up the dimmer and send it for 

repair.

 

Summary of Contents for PAD07

Page 1: ...with a Secured enabled controller to fully utilize the device Its functionality and supported command classes is identical when included as a secure and non secure device Adding to Z WaveTM Network In the front casing there is an on off button also an include button with LED indicator below which is used to dim on and off or carries out inclusion exclusion reset or association When first power app...

Page 2: ...ause the PAD07 to send its NIF 2 There are two groups for the dimmer Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller LED Indication To distinguish what mode the switch is in view from the LED for identification State Type LE...

Page 3: ...will report MULTILEVEL_SWITCH_REPORT ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION 2 1 Grouping 1 Lifeline Maximum 5 nodes 2 1 1 Device reset locally notification When PAD07 is reset manually it will send a DEVICE_RESET_LOCALLY_ NOTIFICATION to the nodes of group 1 2 1 2 On Off Event Report When on or off state has been changed it will send Multilevel Switch Report to the nodes of Grouping 1 ...

Page 4: ...m down to Off 3 4 restore dimmer state Whenever the AC power return from lost PAD07 will restore the switch state which could be Dimmer off Last dimmer state Dimmer on The default setting is Last dimmer state 4 Firmware update over the air OTA PAD07 is based on 500 series SoC and supports Firmware Update Command Class it can receives the updated firmware image sent by controller via the Z wave RF ...

Page 5: ...Minimum 40 m in door 100m outdoor line of sight Modulation Type FSK Frequency Shift Keying Specifications are subject to change and improvement without notice FCC ID RHHPAD07 Warning Do not use Non Dimmable LED lamps DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electrician Observe national regulations Any works introducing changes into th...

Page 6: ...nterference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rec...

Reviews: