background image

Group Number 

Maximum 
Nodes 

Description 

Lifeline 

Control other devices on single click of the button. BASIC command (on/off) is sent according to 
switching state of the load. 

Configuration Parameters 

Z-Wave products are supposed to work out of the box after inclusion, however certain 
configuration can adapt the function better to user needs or unlock further enhanced features. 

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values 

in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. 
For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = 
minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may 
needed to be given as negative values too. 

Parameter 1: LED Operation Mode 

Defines when the LED shall shine and how

 

Size: 1 Byte, Default Value: 1 

Setting 

Description 

LED off, only blinks on traffic 

Defined by Parameter 21 and 22 

Parameter 2: Auto Off 

Defines if and after which time the device shall turn off without any user interaction

 

Size: 2 Byte, Default Value: 0 

Setting 

Description 

no auto off 

1 - 65535 

seconds 

Parameter 3: Switching behavior when receiving wireless OFF 

 
Size: 1 Byte, Default Value: 0 

Setting 

Description 

Switches off 

Ignores Off command 

Switches on 

Switches on, when receiving off command and current state is off 

Parameter 4: Button Mode 

Summary of Contents for POPE700397

Page 1: ...Popp Smart Outdoor Plug SKU POPE700397 ...

Page 2: ...wo way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a device supports secur...

Page 3: ...d against re switching Installation The device can be plugged into every standard power outlet Type F Thanks to IP44 rating this device can be used in wet environments such as bathrooms or basements and even outdoor Do not stack the device Inclusion Exclusion On factory default the device does not belong to any Z Wave network The device needs to be added to an existing wireless network to communic...

Page 4: ...rmware over the air The update function needs to be supported by the central controller Once the controller starts the update process perform the following action to confirm the firmware update Single Click the button to confirm the update Association one device controls an other device Z Wave devices control other Z Wave devices The relationship between one device controlling another device is ca...

Page 5: ...o set a value of 200 minus 256 minus 56 In case of a two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Parameter 1 LED Operation Mode Defines when the LED shall shine and how Size 1 Byte Default Value 1 Setting Description 0 LED off only blinks on traffic 1 Defined by Parameter 21 and 22 Parameter 2 Auto Off Defines if and after which tim...

Page 6: ...hing state Parameter 21 LED Color on OFF state Defines the behavior of the LED when the load is switched off Size 1 Byte Default Value 0 Setting Description 0 Off 1 Red 2 Green Parameter 22 LED Color on ON state Defines the behavior of the LED when the load is switched on Size 1 Byte Default Value 2 Setting Description 0 Off 1 Red 2 Green Parameter 23 Voltage Report Threshold Report the voltage wh...

Page 7: ... parameter for a time set in parameter 28 the soft ciruit breaker will disconnect the load Size 2 Byte Default Value 3600 Setting Description 0 Disabled 1 3600 W Parameter 27 Soft Circuit Breaker Recovery Time Once the soft circuit breaker tipps and the load is disconnected the load will be automatically reconneced after X seconds When disabled the load must be repowered manually or with wireless ...

Page 8: ...15 Z Wave Product Id 0x0154 0x0003 0x000a Frequency Europe 868 4 Mhz Maximum transmission power 5 mW Supported Command Classes Basic Switch Binary s2 Unauth Class Sensor Multilevel s2 Unauth Meter s2 Unauth Association Grp Info s2 Unauth Device Reset Locally s2 Unauth Central Scene s2 Unauth Zwaveplus Info Supervision Configuration s2 Unauth Manufacturer Specific s2 Unauth Powerlevel s2 Unauth Pro...

Page 9: ...ral organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued ...