Group Number
Maximum
Nodes
Description
1
5
Lifeline
2
5
Control other devices on single click of the button. BASIC command (on/off) is sent according to
switching state of the load.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain
configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT:
Controllers may only allow configuring signed values. In order to set values
in the range 128 ... 255 the value sent in the application shall be the desired value minus 256.
For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 =
minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.
Parameter 1: LED Operation Mode
Defines when the LED shall shine and how
Size: 1 Byte, Default Value: 1
Setting
Description
0
LED off, only blinks on traffic
1
Defined by Parameter 21 and 22
Parameter 2: Auto Off
Defines if and after which time the device shall turn off without any user interaction
Size: 2 Byte, Default Value: 0
Setting
Description
0
no auto off
1 - 65535
seconds
Parameter 3: Switching behavior when receiving wireless OFF
Size: 1 Byte, Default Value: 0
Setting
Description
0
Switches off
1
Ignores Off command
2
Switches on
3
Switches on, when receiving off command and current state is off
Parameter 4: Button Mode