This parameter defines if the local button shall control (switch) the load or it is only used to
send out scene control commands to the central controller.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Controls Load + Controls Scenes
1
Scene Control Only
Parameter 5: Status after Power Failure
Defines the switching status after a power failure or unplugging
Size: 1 Byte, Default Value: 1
Setting
Description
0
Always off
1
Return to last switching state
Parameter 21: LED Color on OFF state
Defines the behavior of the LED when the load is switched off
Size: 1 Byte, Default Value: 0
Setting
Description
0
Off
1
Red
2
Green
Parameter 22: LED Color on ON state
Defines the behavior of the LED when the load is switched on
Size: 1 Byte, Default Value: 2
Setting
Description
0
Off
1
Red
2
Green
Parameter 23: Voltage Report Threshold
Report the voltage when the voltage has changed by more then X * 1 V. When disabled the
device will report every 10 minutes regardless of current voltage.
Size: 1 Byte, Default Value: 100
Setting
Description
0
Disabled
1 - 250
Volt
Parameter 24: Current Reporting Threshold