This parameter defines if the local button shall control (switch) the load or it is only used to 
send out scene control commands to the central controller.

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Controls Load + Controls Scenes 

Scene Control Only 

Parameter 5: Status after Power Failure 

Defines the switching status after a power failure or unplugging

 

Size: 1 Byte, Default Value: 1 

Setting 

Description 

Always off 

Return to last switching state 

Parameter 21: LED Color on OFF state 

Defines the behavior of the LED when the load is switched off

 

Size: 1 Byte, Default Value: 0 

Setting 

Description 

Off 

Red 

Green 

Parameter 22: LED Color on ON state 

Defines the behavior of the LED when the load is switched on

 

Size: 1 Byte, Default Value: 2 

Setting 

Description 

Off 

Red 

Green 

Parameter 23: Voltage Report Threshold 

Report the voltage when the voltage has changed by more then X  * 1 V. When disabled the 
device will report every 10 minutes regardless of current voltage.

 

Size: 1 Byte, Default Value: 100 

Setting 

Description 

Disabled 

1 - 250 

Volt 

Parameter 24: Current Reporting Threshold 

Summary of Contents for POPE700397

Page 1: ...Popp Smart Outdoor Plug SKU POPE700397 ...

Page 2: ...wo way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a device supports secur...

Page 3: ...d against re switching Installation The device can be plugged into every standard power outlet Type F Thanks to IP44 rating this device can be used in wet environments such as bathrooms or basements and even outdoor Do not stack the device Inclusion Exclusion On factory default the device does not belong to any Z Wave network The device needs to be added to an existing wireless network to communic...

Page 4: ...rmware over the air The update function needs to be supported by the central controller Once the controller starts the update process perform the following action to confirm the firmware update Single Click the button to confirm the update Association one device controls an other device Z Wave devices control other Z Wave devices The relationship between one device controlling another device is ca...

Page 5: ...o set a value of 200 minus 256 minus 56 In case of a two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Parameter 1 LED Operation Mode Defines when the LED shall shine and how Size 1 Byte Default Value 1 Setting Description 0 LED off only blinks on traffic 1 Defined by Parameter 21 and 22 Parameter 2 Auto Off Defines if and after which tim...

Page 6: ...hing state Parameter 21 LED Color on OFF state Defines the behavior of the LED when the load is switched off Size 1 Byte Default Value 0 Setting Description 0 Off 1 Red 2 Green Parameter 22 LED Color on ON state Defines the behavior of the LED when the load is switched on Size 1 Byte Default Value 2 Setting Description 0 Off 1 Red 2 Green Parameter 23 Voltage Report Threshold Report the voltage wh...

Page 7: ... parameter for a time set in parameter 28 the soft ciruit breaker will disconnect the load Size 2 Byte Default Value 3600 Setting Description 0 Disabled 1 3600 W Parameter 27 Soft Circuit Breaker Recovery Time Once the soft circuit breaker tipps and the load is disconnected the load will be automatically reconneced after X seconds When disabled the load must be repowered manually or with wireless ...

Page 8: ...15 Z Wave Product Id 0x0154 0x0003 0x000a Frequency Europe 868 4 Mhz Maximum transmission power 5 mW Supported Command Classes Basic Switch Binary s2 Unauth Class Sensor Multilevel s2 Unauth Meter s2 Unauth Association Grp Info s2 Unauth Device Reset Locally s2 Unauth Central Scene s2 Unauth Zwaveplus Info Supervision Configuration s2 Unauth Manufacturer Specific s2 Unauth Powerlevel s2 Unauth Pro...

Page 9: ...ral organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued ...

Reviews: