background image

3

In

te

rf

a

c

e

Defines I/O Interface

INTERFACE

8000se Series

FormsMaster

*Factory Default Setting

Interface Setup 

allows you to 

set your printer 

interface 

parameters

Functions

Possible Values

Description

I/O:

Parallel/LAN* or Serial

Selects active I/O port.  NOTE: Must press S UBMENU 
button to select desired I/O port.

Serial

Emulation:

Epson*, IBM Proprinter, DEC 
LA120/210, TTY, Printek, ANSI 
X3.64, Genicom 3840, Genicom 
3410

Selects current emulation mode.

Auto.CR:

Off or On*

Enable or disable automatic Carriage Returns (CR) when a 
Line Feed (LF), Vertical Tab (VT), or Form Feed (FF) is 
received.

Auto. LF:

Off* or On

Enables or disables automatic Line Feed (LF) when a 
Carriage Return (CR) is received.

FF at TOF:

No*, Yes

Sets whether Form Feed (FF) occurs when received from 
the host computer if paper is already positioned at the Top 
Of Form (TOF).

Chars:

Control*, Printable

Selects whether certain control character symbols are 
printed (emulation dependent) or are treated as control 
characters.

Min Buffer:

No*, Yes

Selects whether the smallest possible I/O buf fer should be 
used.

Baud Rate:

110, 150, 300, 600, 1200, 2400, 4800, 
or 9600*

Selects baud rate for serial interface (Not available when 
Parallel/LAN is selected).

Data Bits:

7 or 8*

Selects number of data bits in Serial character f rame and 
the number of significant data bits in each charac ter 
received via all other interfaces.

Stop Bits:

1* or 2

Sets the number of stop bits to be used at the end of t he 
serial character frame.  Must be set to matc h the stop bit 
setting on the host computer.

Parity:

None*, Even or Odd

Selects parity checking requirements for Serial dat a bits. 
(Not available when Parallel/LAN is selected).

Busy:

Low* or High

Selects polarity of busy signal (pin 11 of RS-232C 
interface).  Available only when serial is selected.

DTR:

Power On/Off*, Online/Offline or 
Busy/Not Busy

Selects condition reflected by DTR signal (pin 20 of RS-
232C interface).  Available only when serial is selected.

XON/XOFF:

Off* or On

Enables or disables transmission of XON and XOFF 
characters from printer to host control data flow to print er.  
(Not available when Parallel/LAN is selected).

ETX/ACK:

Off* or On

Enables or disables ACK response to receipt of ETX 
character.  (Not available when Parallel/LAN is selected).

RTS/CTS:

Power On or Off*

Supports hardware handshaking for data flow control.  For 
Host systems using Full-duplex communic ations.

Parallel/LAN

Emulation:

Epson*, IBM Proprinter, DEC 
LA120/LA210, TTY, Printek, ANSI 
X3.64, Genicom 3840, Genicom 
3410

Selects current emulation mode.

LAN Setup

Off* or On

Enables or disables LAN setup features.

IP Address Method:

Auto* or Static

Allows either the host to set IP Address or enter a speci fic 
IP Address from the printer's front panel.  (LAN s etup must 
be set to ON).

IP Address:

192.168.0.27*,…

Enter a specific IP Address from the print er's front panel.  
(Address Method must be set to Static).

Subnet Mask:

255.255.255.0*,…

Enter a specific Subnet IP Address from t he printer's front 
panel.  (Address Method must be set to Static).

IP Gateway:

192.168.0.0,…

Enter a specific Gateway IP Address from the printer' s front 
panel.  (Address Method must be set to Static).

Auto. CR:

Off or On*

Enables or disables automatic Carriage Returns (CR) when 
a Line Feed (LF), Vertical Tab (VT), or Form Feed (FF) is 
received.

Auto. LF:

Off * or On

Enables or disables automatic Line Feed (LF) when a 
Carriage Return (CR) is received.

FF at TOF:

No* or Yes

Sets whether Form Feed (FF) occurs when received from 
the host computer if paper is already positioned at the Top 
Of Form (TOF).

Chars:

Control*, Printable

Selects whether certain control character symbols are 
printed (emulation dependent) or are treated as control 
characters.

Min Buffer:

No* or Yes

Selects whether the smallest possible I/O buf fer should be 
used.

Reviews: