Examples
enclosure
enclosure -v
enclosure -a mod -s “tempwarning=40,tempcritical=70”
ctrltempwarning=
Controller temperature, displayed in Celsius, that the controller will
consider as a warning threshold.
(61-65) For IOM sensor 1,4.
(66-70) For IOM sensor 2,5.
(71-78) For IOM sensor 3,6.
ctrltempcritical=
Controller temperature, displayed in Celsius, that the controller will
consider as a critical threshold.
(68-72) For IOM sensor 1,4.
(73-77) For IOM sensor 2,5.
(81-88) For IOM sensor 3,6.
-t <FRU type>
Used with action locate to indicate which type of FRU to locate. If -t is not
specified, it indicates to locate the enclosure.
ctrl
To locate controller.
cooling
To locate cooling unit. It only works with SAS type enclosure.
psu
To locate power supply unit. It only works with SAS type enclosure.
-f <FRU id>
Used with action locate and -t <FRU type> option to indicate which FRU
to locate. The valid values for FRU id are 1,2,3 and 4.
-v
Verbose mode. Used with -a list. VPD information will also be displayed
when using this switch.
159
Promise
Technology
Managing with CLI