Example of the commanded string to select Inputs:
FUNCTION
COMMAND
VARIABLES
Select source
Source xxx;
xxx = Input Channel (001=Source1, 002=Source2)
COMMAND ExAMPLE
RESPONSE
DESCRIPTION
Source 001;
Source 001#ok;
Select source number 1
ETHERNET SERIAL INTERFACE CONNECT A PC OR CONTROL SYSTEM VERSION COMPATIBLE V2.0
For a complete list of commands, please reference external document extended Ethernet Protocol Instruction Manual.
ETHERNET SERIAL INTERFACE
PIN ETHERNET REFERENCE
1
TXOP
TX +
2
TXON
TX -
3
RXIP
RX +
4
NC
5
NC
6
RXIN
RX -
7
NC
8
GND
RS-232 SERIAL INTERFACE CONNECT A PC OR CONTROL SYSTEM. VERSION COMPATIBLE V2.0
For a complete list of commands, please reference external document extended RS-232 Protocol Instruction Manual.
RS-232 CONFIGURATION
RS-232 cable is a straight thru cable and not null-modem
Definition
Pin
Pin
Definition
1
1
DCD
TX
2
2
RX
RX
3
3
TX
4
4
DTR
GND
5
5
GND
6
6
DSR
7
7
RTS
8
8
CTS
9
9
RI
RS-232
RS-232 SERIAL INTERFACE PROTOCOL COMMANDS ( ETHERNET / RS-232 CONTROL DRIVER V2.0 )
The Shinybow switcher can be controlled via the RS-232 serial control port to allow for interfacing to a PC, or similar third party control
system.
The serial communication parameters are 9600 baud, 8 bit, No Parity and 1 stop bit - this is often referred to as 9600 8N1.
When the unit recognises a complete command it will perform the requested action - there is no delimiter character required.
25
ETHERNET & RS-232 SERIAL INTERFACE
PC
Shinybow
Device
ETHERNET TCP/IP PROTOCOL COMMANDS
( ETHERNET / RS-232 CONTROL DRIVER V2.0 )
** The Ethernet port and RS-232 port
CANNOT
be used
simultaneously. Any connection to the Ethernet Control port
will
DISABLE serial commands sent to the RS-232 port.**
Note :
Control the switcher
SPD : Speed
LINK : Ethernet link
RJ-45 Female 8P-8 Connector
RS-232 PIN DIAGRAM