Reset_MOBY_U
Figure B-5 "Reset_MOBY_U" function block
Table B- 5
Explanation of the "Reset_MOBY_U" function block
Parameter
Data type
Default value Description
TAG_CONTROL
Bool
True
Presence check
DISTANCE
Byte
23h
Range limitation (range of values: 0x02 -
0x23 or 0x82 - 0xA3 for reduced transmit
power)
MULTITAG
Byte
1
Maximum number of transponders that can
be processed at the same time in the
antenna field. (Range of values: 0x01 -
0x12)
SCAN_TIME
Byte
0
Scanning time: Standby time of the
transponder (range of values: 0x00 - 0xC8)
FCON
Byte
0
field_ON_control: BERO mode (range of
values: 0x00 - 0x03)
FTIM
Byte
0
field_ON_time: Time for BERO mode
(range of values: 0x00 - 0xFF)