V02.00 | 2020/08
197
9
Operation
9.1
Executing a command and calling data
NOTE
A command is successful when the response code is the same as the command
code.
Set the parameters for the command.
Set command code.
a
Set the command code. The command is successful when the response code is the same
as the command code and no error message is present.
9.2
Using fragmentation
If more data is read than the set size of the data interface, the fragment counter is automatically
incremented in the input data.
To read more data, increase the fragment counter in the output data.
Repeat process until the read or write fragment no. in the input data equals 0.
If less data is read than the set size of the data interface, the fragment counter stays at 0.
9.3
Using commands with a loop counter function
NOTE
The loop counter is only supported for fast execution commands.
Setting the command: Enter the command code.
Set the loop counter to 1.
a
The command was successfully executed if the same command code appears in the pro-
cess input data as in the process output data. The RFID data is stored in the buffer of the
interface.
Repeating the command: Increase the loop counter in the output data by 1.
a
The command was successfully executed if the same loop counter value appears in the
process input data as in the process output data. The RFID data is stored in the buffer of
the interface.
Setting a new command: Set the new command code and set the loop counter to 0.