Chapter 3. Legacy CLI Syntax Reference
92
3ware 9000 Series Serial ATA Controller CLI Guide
info
cid
stagger
This command shows the delay between drive groups that spin up at one time
on this controller
Example:
//localhost> info c0 stagger
/c0 Spinup Stagger Time Policy (sec) = 2
info
cid uid
This command presents detailed information on the specified unit. If the unit
consists of sub-units as is the case in RAID 1, RAID 5, RAID 10, and RAID
50 arrays (applicable for 9000 controllers), then details about each sub-unit
are also presented. One application of this command is to see which sub-unit
of a degraded unit has caused the unit to degrade and which disk within that
sub-unit is the source of degradation.
Example:
//localhost> info c0 u0
Unit UnitType Status %Cmpl Port Stripe Size(GB) Blocks
---------------------------------------------------------------
u0 RAID-5 VERIFYING 0 - 16K 819.446 718503424
u0-0 DISK OK - p0 - 74.4951 156227584
u0-1 DISK OK - p1 - 74.4951 156227584
u0-2 DISK OK - p2 - 74.4951 156227584
u0-3 DISK OK - p3 - 74.4951 156227584
u0-4 DISK OK - p4 - 74.4951 156227584
u0-5 DISK OK - p5 - 74.4951 156227584
u0-6 DISK OK - p6 - 74.4951 156227584
u0-7 DISK OK - p7 - 74.4951 156227584
u0-8 DISK OK - p8 - 74.4951 156227584
u0-9 DISK OK - p9 - 74.4951 156227584
u0-10 DISK OK - p10 - 74.4951 156227584
u0-11 DISK OK - p11 - 74.4951 156227584
info
cid uid
status
This command presents the status of the specified unit.
Example:
//localhost> info c0 u5 status
/c0/u5 status=DEGRADED