Port Object Commands
www.3ware.com
71
Warning:
Use caution when using this command as this operation
will degrade any redundant units. This command will fail if you
attempt to remove a drive from a non-redundant unit. After the
drive is removed in CLI it can be removed physically, without
powering down the system if a hot swap carrier is available.
System hangs and damage can occur if a hot swap carrier is not
used.
/cx/px set identify=on|off
This command applies only to 9550SX model controllers.
This command sets the LED status of the port to
on
or
off
. If identify is set to
on
, the firmware activates the setting of the corresponding LED of the port on
the controller and causes it to blink.
Note:
This feature will be supported by chassis vendors. It requires a chassis
with support for Chassis Control Unit (CCU). The CCU will also support the
monitoring of fan speed, temperature sensors, door lock, and so forth,
depending on the level of chassis vendor support. Check the 3ware support
web site for future updates on a list of chassis vendors that support the CCU,
as they become available.
Example:
//localhost> /c0/p5 set identify=on
Setting Port Identify on /c0/p5 to [on] ... Done.