OPERATING AND USER MANUAL Q-12 CoaXPress series
________________________________________________________________________________________________________________
_________________________________________________________________________________________
Adimec
45
7.12.2 LUTSelection
| RW | E |
ISSUE 2 ONLY
ProgrammableLUT
In this mode the LUT can be fully programmed.
Gamma
In this mode a gamma curve will be used as the LUT. The gamma will be
applied by filling the LUT according to following formula:
𝑂𝑢𝑡𝑝𝑢𝑡
= 1023
∙ �
𝐼𝑛𝑝𝑢𝑡
1023
�
𝐺𝑎𝑚𝑚𝑎𝐹𝑎𝑐𝑡𝑜𝑟
The Gamma factor can be set with the GammaFactor feature.
7.12.3 LUTStart
| WO | E |
Command
Start the creation of a LUT. The exact amount of 1024 entries should be
written using the LUTValue feature to successfully create a LUT.
7.12.4 LUTValue
| RW | E |
0 to 1023,
Increment: 1
After executing LUTStart, use this feature to consecutively write each index
of the LUT. This feature also returns the value that is written at the LUT
index selected with the LUTIndex feature.
This feature is automatically updated if any of the following features is changed:
LUTIndex
7.12.5 LUTEnd
| WO | E |
Command
Finish the creation of a LUT. Make sure you wrote a value to all 1024 LUT
entries.
7.12.6 LUTIndex
| RW | E |
0 to 1023,
Increment: 1
Select the LUT index for which you want to know the assigned value. The
assigned value will be displayed in the LUTValue feature.
7.12.7 LUTStatus
| RO | E |
LUT_Idle
LUT programming sequence in idle situation.
LUT_Started
LUT programming sequence started.
LUT_Restarted
LUT programming sequence restarted.
LUT_TooMuchEntries
Too much LUT entries (LUTValue) written before LUTEnd command is
written.
LUT_NotEnoughEntries
Not enough LUT entries (LUTValue) written before LUTEnd command is
written.
LUT_Stored
LUT programming sequence finished and stored in memory.
LUT_NotStarted
LUT programming sequence has not been started yet.