LF_FF_SequenceProgrammingNotStarted
The sequence programming has not yet started.
LF_FF_SequenceProgramLimitReached
The maximum sequence length of 2000 entries has
been reached.
LF_FF_SequenceSaved
The current sequence has been saved to non-volatile
memory.
LF_FF_SequenceLoaded
The sequence that was stored in the non-volatile
memory has been loaded as the active sequence.
LF_FF_SequenceLoadFailed
The sequence that was stored in the non-volatile
memory could not be loaded.
This feature is automatically updated if any of the following features is changed:
LF_FF_SequenceLoad, LF_FF_SequenceSave, LF_FF_SequenceSet, LF_FF_SequenceStartProgram,
LF_FF_SequenceStopProgram
7.17.13
LF_FF_SequenceTotal
| RO | B |
Integer
Returns the total amount of sequence entries that have been written.
This feature is automatically updated if any of the following features is changed:
LF_FF_SequenceLoad, LF_FF_SequenceSet, LF_FF_SequenceStartProgram
7.17.14
LF_FF_SequenceSave
| WO | B |
Command
Save the programmed sequence to non-volatile memory.
7.17.15
LF_FF_SequenceLoad
| WO | B |
Command
Load the programmed sequence from non-volatile memory.
7.17.16
LF_FF_SequenceReset
| WO | B |
Command
Reset the sequencer pointer to the first step during sequenced correction.
7.17.17
LF_FF_SequenceRepeat
| RW | B |
True
Every time the sequencer pointer reaches the last sequence entry, the
sequence will be reset and started again from the first sequence entry.
False
After reaching the last sequence entry, the sequence stops and the last
sequence entry remains the active FF correction set.
7.17.18
LF_FF_
SequenceReadCurrentSet
| WO | B |
Command
Reads the set number which is currently used for correction. The value that
is read is returned in the “LF_FF_SequenceSet” feature.
7.17.19
LF_FF_
SequenceIndexSelector
| RW | B |
0 to 1999,
Increment: 1
Select the sequence index that will be read with
LF_FF_SequenceReadSelectedIndex command.