6.1.5.5.
APDU2 Command (From FW v1.20 and later)
This command sends an APDU command which support extended APDU to the reader.
Command Format
Offset
Field
Size
Value
Description
0
bMessageType
1
67h
-
1
LEN1 LEN2 (wLength)
2
-
Number of extra bytes starting from
the next field for this message. It is
expressed in two bytes long. LEN1 is
LSB while LEN2 is MSB. (Maximum
length is 263)
3
Data
Param
1
-
Parameter:
Short APDU level
00h – default
Extended APDU level
00h – the command APDU begins and
ends with this command.
01h – the command APDU begins with
this command and continues in next
APDU command.
02h – this Data field continues a
command APDU and ends the APDU
command.
03h – this Data field continues a
command APDU and another block is
to follow.
10h – empty Data field, continuation of
response APDU is expected in the
next Response.
4
APDU CMD
N
-
APDU Command
(Maximum length is 261)
4+N
CSUM (wChecksum)
1
-
CSUM means the XOR values of all
bytes in the Data