Website:-www.bholanath.in
E-mail id:-support@bholanath.in
25
STOP: Stop
Slave Address
Function Code
Holding ADDR
Op-Code
01
06
0x25
06
Note:
Command: 01, 06, 00,25,00,06
01 -> Slave Address
06* -> Function Code
00* -> LSB Address of Holding Register
25* -> MSB Address of Holding Register
00, 06* -> Op-code for STOP the motor
(* indicates these values are fixed
)
Response: 01, 06, 00,25,00,06
HOLD: Hold
Slave Address
Function Code
Holding ADDR
Op-Code
01
06
0x25
07
Note:
Command: 01, 06, 00,25,00,07
01 -> Slave Address
06* -> Function Code
00* -> LSB Address of Holding Register
25* -> MSB Address of Holding Register
00, 07* -> Op-code for HOLD the motor
(* indicates these values are fixed
)
Response: 01, 06, 00,25,00,07
RELEASE: Release
Slave Address
Function Code
Holding ADDR
Op-Code
01
06
0x25
08
Note:
Command: 01, 06, 00,25,00,08
01 -> Slave Address
06* -> Function Code
00* -> LSB Address of Holding Register
25* -> MSB Address of Holding Register
00, 08* -> Op-code for RELEASE the motor
(* indicates these values are fixed
)
Response: 01, 06, 00,25,00,08
SET_DEFAULT_CODE:
This command is used in Auto cycle programming. When program is send to
device then by sending this command we can set sent auto cycle program as default program
for device.