Programmable DC Electronic Load 63600 Series Operation & Programming Manual
5-52
Query Syntax:
CURRent:STATic:RISE?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = A/
μs]
Query Example:
CURR:STAT:RISE?
CURR:STAT:RISE? MAX
CURR:STAT:RISE? MIN
CURRent:SWEep:DUTY
Type:
Channel-Specific
Description:
Set the duty cycle for constant current frequency sweep mode.
Setting Syntax:
CURRent:SWEep:DUTY<space><NRf+>
Setting Parameters:<NRf+>, 1% ~ 99%, Resolution = 1%
Setting Example:
CURR:SWE:DUTY 50
Set duty cycle = 50%
CURR:SWE:DUTY MAX
Set duty cycle = maximum value.
CURR:SWE:DUTY MIN
Set duty cycle = minimum value.
Query Syntax:
CURRent:SWEep:DUTY?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = None]
Query Example:
CURR:SWE:DUTY?
CURR:SWE:DUTY? MAX
CURR:SWE:DUTY? MIN
CURRent:SWEep:DWELl
Type:
Channel-Specific
Description:
Set the dwell time for constant current frequency sweep mode.
Setting Syntax:
CURRent:SWEep:DWELl<space><NRf+>[suffix]
Setting Parameters:<NRf+>, 1ms ~ 100s, Resolution = 1ms, Unit = Second
Setting Example:
CURR:SWE:DWEL 50
Set dwell time = 50s
CURR:SWE:DWEL 500ms
Set dwell time = 0.5s
CURR:SWE:DWEL MAX
Set dwell time = maximum value.
CURR:SWE:DWEL MIN
Set dwell time = minimum value.
Query Syntax:
CURRent:SWEep:DWELl?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Second]
Query Example:
CURR:SWE:DWEL?
CURR:SWE:DWEL? MAX
CURR:SWE:DWEL? MIN
CURRent:SWEep:FALL
Type:
Channel-Specific
Description:
Set the falling slew rate of current for constant current frequency
sweep mode.
Setting Syntax:
CURRent:SWEep:FALL<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: CURR:SWE:FALL 2.5
Set falling slew rate to 2.5A/
μs.
CURR:SWE:FALL 1A/
μs
Set falling slew rate to 1A/
μs.
CURR:SWE:FALL MAX
Set falling slew rate to the
maximum value of static load.
CURR:SWE:FALL MIN
Set falling slew rate to the
minimum value of static load.
Query Syntax:
CURRent:SWEep:FALL?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = A/
μs]
Query Example:
CURR:SWE:FALL?
CURR:SWE:FALL? MAX
CURR:SWE:FALL? MIN
CURRent:SWEep:FEND