Modular Multi-service Integrated Optical Transmission Multiplexer
User Manual
28
e.g.:
setR M loop on 1 2 4 7 8
; Enable signal loopback for remote 1,2,4,7,8
channels of 2M
setR M loop off 3 4 5 6 7
; Disable signal loopback for remote 3,4,5,6,7
channels of 2M
Configure the 2M indicator on the panel to indicate the local or the remote:
setL M disp L
; Indicating the local alarm
setL M disp R
; Indicating the remote alarm
5. Optical circuit configuration
Optical circuit loopback configuration:
setL O loop on
; Enable optical circuit loopback
setL O loop off
; Disable optical circuit loopback
Mandatory selection of optical interface for optical circuit:
setL O auto [opl/sys/e-3/e-6]
; Configure optical interface
auto-negotiating
setL O force A
; Mandatorily configure to Aoptical interface
setL O force B
; Mandatorily configure to Boptical interface
<NOTE>
Opl: Optical interface auto-negotiating, switching upon an optical loss alarm
sys: Optical interface auto-negotiating, switching upon a framing out-of-step alarm
e
3
: Optical interface auto-negotiating, switching upon a line 10
-3
error code alarm
e
6
: Optical interface auto-negotiating, switching upon a line10
-6
error code alarm
Default: sys
,
i.e. switching upon a framing out-of-step alarm
6. Ethernet configuration
Mandatory configuration of local Ethernet
setL E force [1 2 3 4] F A/B
; Set PORT 1, 2, 3, 4 of Ethernet to F-DX
setL E force [1 2 3 4] H A/B
; Set PORT 1, 2, 3, 4 of Ethernet to H-DX
setL E auto
; Ethernet auto-negotiating
A→100M; B→10M