Tamarisk
®
320
Software ICD
30
Command Format:
Table 45 – System Status Get Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0xF2
System Status Get Command ID.
3
0x00
Parameters length.
4
checksum
Frame check sequence.
Response Format:
Two responses are generated, a system status get response and an ACK response.
Table 46 – System Status Get First Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0xF2
ACK Response
3
0x10
Parameters length.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
4
(deprecated)
(deprecated)
EXTVID
0=in
1=out
2=off
CAL
0=none
1=2 pt cold
2=2 pt hot
3=1 pt
4=1 pt – no
shutter
5
AGC
0=off
1=log equal (auto)
2=manual
3=linear equal
(deprecated)
Always reads 3
SHUTTE
R
0=closed
1=open
(deprec
ated)
(deprec
ated)
POL
0=blk
1=wht
6
(deprecated)
Always reads 0x0
(deprecated)
7
Unsigned integer
Deprecated
8, 9
Unsigned integer
Manual Gain
10, 11
Unsigned integer
Manual Level
12, 13
Unsigned integer
Gain Bias
14, 15
Unsigned integer
Level Bias
16, 17
Unsigned integer
Deprecated (always 0).
18, 19
Unsigned integer
Deprecated (always 0).
20
chksm
Frame check sequence.