Tamarisk
®
320
Software ICD
51
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x84
AGC ROI Get Limit Command ID.
6
checksum
Frame check sequence.
Command Format (sub-command 0x0002, Set):
Table 100 – AGC ROI Set Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0x84
AGC ROI Set Command ID.
3
0x0A
Parameters length.
4, 5
0x0002
Sub-command Set ROI.
6, 7
Unsigned integer
XSTART, within valid limits (see Get Limit)
8, 9
Unsigned integer
YSTART, within valid limits (see Get Limit)
10, 11
Unsigned integer
XSTOP, within valid limits (see Get Limit)
12, 13
Unsigned integer
YSTOP, within valid limits (see Get Limit)
14
checksum
Frame check sequence.
Response Format:
Table 101 – AGC ROI Set Command ACK Response Format
Byte
Value
Description
1
0x01
Start of message.
2
0x02
ACK Response
3
0x02
Parameters length.
4, 5
0x84
AGC ROI Set Command ID.
6
checksum
Frame check sequence.
Command Format (sub-command 0x0003, Burn to NV Param):
Table 102 – AGC ROI Burn to NV Params Command Format
Byte
Value
Description
1
0x01
Start of message.
2
0x84
AGC ROI Burn to NV Params Command ID.
3
0x02
Parameters length.
4, 5
0x0003
Sub-command Burn ROI to NV Param.
6
checksum
Frame check sequence.