FACTORY DEFAULTS
MASTER PROGRAMMING CODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123456
ENTRY CODE LENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DIGITS
REQUEST-TO-EXIT OUTPUT RELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MAIN RELAY
ALARM SHUNT OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISABLED
FORCED ENTRY OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OUTPUT #3
DOOR AJAR OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OUTPUT #4
MAIN RELAY ON TIME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
AUXILIARY RELAY ON TIME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
SOLID STATE OUTPUT #3 ON TIME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
SOLID STATE OUTPUT #4 ON TIME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SECONDS
DOWNLIGHT ON TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 MINUTES
DOOR SENSE/INHIBIT INPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DOOR SENSE
KEYPAD LOCKOUT OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISABLED
KEYPAD ACTIVE OUTPUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISABLED
BEEPER SOUNDS WHEN KEY PRESSED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YES
BEEPER SOUNDS DURING RELAY #1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
BEEPER SOUNDS DURING RELAY #2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
BEEPER SOUNDS DURING OUTPUT #3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
BEEPER SOUNDS DURING OUTPUT #4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO
KEYPAD LOCKOUT COUNT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 TRIES BEFORE LOCKOUT
ANTI-PASSBACK TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NO ANTI-PASSBACK
Adding a New Entry Code
Press:
01 # Code # Code # Action #
Code =The new entry code: 1-999999, depending on code length
Action = Relay output entry code will activate as follows:
1 = Relay #1, timed open
2 = Relay #2, timed open
3 = Both Relays, timed open
10 = Relay #1, toggled
20 = Relay #2, toggled
30 = Both Relays, toggled
12 = Relay #1 toggled; Relay #2, timed open
21 = Relay #1 timed open; Relay #2 toggled
The yellow LED will flash quickly while the AK-21W searches its
memory for available space and duplicate entries. The green LED
will light when the new code is stored.
If the new entry code chosen is already being used for another
entry code, the red LED will light. A new
unique
code needs to be
entered.
☞
NOTE: Leading zeros (zeros before the code number, i.e. 0001) do not
need to be entered when programming a new entry code.The AK-21Wwill
internally add any zeros to fill all digits determined by the entry code length
setting. Leading zeros will have to be entered by the user when entering their
code to gain access.
AUTO-RELOCK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ON
BASIC PROGRAMMING
When the AK-21W is in Programming Mode, both indicators will
turn off until programming begins. After a programming option
number is entered the yellow indicator will blink. This shows that the
AK-21W is ready to accept the new programming data. After the
new data entry is complete, the yellow indicator will flash while
the data is being stored. The green indicator will light if the data
is accepted. The red indicator will light if any programming data
is entered incorrectly, and the command will have to be fully
re-entered.
Entering Programming Mode
The 6-digit Master Programming Code (default = 123456) is used to enter
Programming Mode.
Press:
#
9
#
Master Code
Master Code
= the current 6-digit Master Programming Code
Exiting Programming Mode
Press:
* *
#
The red indicator will light after exiting Programming Mode.
☞
NOTE: The AK-21Wwill automatically exit Programming Mode after two
minutes of inactivity.
Re-entering a Command After a Mistake
If the red indicator lights, signaling an incorrect entry, or an incorrect key is
pressed during programming, to clear the keypad and re-enter the command:
Press:
*
9
#
Setting Entry Code Length
Default: 4 digits
Press:
0
3
#
Length
#
Length
= 1 - 6 for entry code length
☞
NOTE: If the Entry Code Length is going to be changed fromthe factory
default of four digits, make this change first, before programming any
entry codes.
Erasing a Single Entry Code
Press:
0
2
#
Code
#
Code
#
Code
=The entry code to delete.
The yellow indicator will flash quickly while the AK-21W searches
its memory for the code to erase. The green indicator will light
when the code is erased.
Erasing All Entry Codes
★
WARNING: PERFORMING THIS COMMAND WILL
REMOVE ALL ENTRY CODES FROM THE MEMORY.
Press:
9
7
#
0
0
0
0
0
0
#
0
0
0
0
0
0
#
☞
NOTE: The green indicator will light while the memory is being erased.This
may take up to 15 seconds.
Changing the 6-Digit Master Programming Code
Press:
9
8
#
Master Code
#
Master Code
#
Master Code
=The new 6-digit Master Programming Code
New master code:
wwww.EntraPASS.com