OBID
i-scan
®
UHF
Manual
ID ISC.MU02.02
FEIG ELECTRONIC GmbH
Page 56 of 96
H90701-3e-ID-B
8. Protocols for Reader Configuration
The Reader configuration protocols allow the Reader to be adapted to the conditions found in indi-
vidual applications. For details about the Protocol Frame see:
6.1. Serial Data Format and Protocol
Access to the configuration parameters is granted only after a
mand with the correct READER-ID.
In order to avoid unauthorized data access, the Reader is equipped with the following protection
mechanism:
Config-Protection:
Access locking for the configuration parameters stored in the EEPROM of the Reader.
8.1. [0x80] Read Configuration
By using the Read Configuration command the actual configuration of the Reader can be detected.
In order to do this, the configuration is read in blocks of 14 bytes each and addressed by CFGn in
the byte CFG-ADR.
Host
→
Reader
1
2
3
4
5-6
6
COM-ADR
[0x82]
CFG-ADR
CRC16
Host
←
Reader
1
2
3
4
5 .. 18
19-20
20
COM-ADR
[0x82]
STATUS
CFG-REC
CRC16
CFG-ADR
Bit:
7
6
5
4
3
2
1
0
Function
LOC
0
CFGn: Address of Configuration Block
CFGn:
memory-address of the required configuration block
LOC:
specifies the location of the configuration block
b0
RAM
b1
EEPROM
CFG-REC:
14 bytes configuration block read from address CFGn in CFG-ADR.
NOTE:
A read configuration from EEPROM with reserved configuration blocks will cause a 0x15
error code.
6
see ANNEX C: Index of Status Bytes
7
see Chapter 7. Configuration Parameters (CFG)